Line Number | Item | Description | Unit | Quantity |
0001 | 201-01-00100 | Clearing and Grubbing | LUMP | 1 |
0002 | 202-01-00100 | Removal of Structures and Obstructions | LUMP | 1 |
0003 | 202-02-00020 | Removal of Drives | SQYD | 3,916 |
0004 | 202-02-02020 | Removal of Asphalt Pavement | SQYD | 8,077.3 |
0005 | 202-02-03010 | Removal of Base – Recycled PCC or Stone | SQYD | 8,077.3 |
0006 | 202-02-04501 | Removal of Bridge (Sta. 105+00, 29' x 185' Trustle Timber Pile Bents) | LUMP | 1 |
0007 | 202-02-04501 | Removal of Bridge (Sta. 182+53, 13' x 26' Timber Bridge) | LUMP | 1 |
0008 | 202-02-04501 | Removal of Bridge (Sta. 191+52, 13' x 26' Timber Bridge) | LUMP | 1 |
0009 | 202-02-04501 | Removal of Bridge (Sta. 246+80, 13' x 26' Timber Bridge) | LUMP | 1 |
0010 | 202-02-04501 | Removal of Bridge (Sta. 286+46, 14' x 54' Timber Bridge) | LUMP | 1 |
0011 | 202-02-06020 | Removal of Concrete Box Culverts (Sta. 140+89, 1' x 1.5' x 25' Box) | EACH | 1 |
0012 | 202-02-06020 | Removal of Concrete Box Culverts (Sta. 141+12, 1' x 1.5' x 27' Box) | EACH | 1 |
0013 | 202-02-06020 | Removal of Concrete Box Culverts (Sta. 326+10, 4' x 4' x 20' Box) | EACH | 1 |
0014 | 202-02-12000 | Removal of Fence | LNFT | 21,890 |
0015 | 202-02-32100 | Removal of Pipe (Cross Drain) (12", 18", 24", 30", 36" and 42") | LNFT | 466 |
0016 | 202-02-32120 | Removal of Pipe (Side Drain) (8", 12", 18", 24", 30" and 36") | LNFT | 665 |
0017 | 202-07-00100 | Plugging Existing Water Wells | EACH | 1 |
0018 | 203-01-00100 | General Excavation | CUYD | 96,847 |
0019 | 203-02-00100 | Drainage Excavation | CUYD | 29,805 |
0020 | 203-03-00100 | Embankment | CUYD | 573,215 |
0021 | 203-04-00200 | Nonplastic Embankment (Sand) | CUYD | 52,429 |
0022 | 203-04-00300 | Nonplastic Embankment (Stone) | CUYD | 474 |
0023 | 203-08-00100 | Geotextile Fabric | SQYD | 113,508 |
0024 | 204-02-00100 | Temporary Hay Bales | EACH | 732 |
0025 | 204-05-00100 | Temporary Sediment Check Dams (Hay) | EACH | 70 |
0026 | 204-05-00200 | Temporary Sediment Check Dams (Stone) | EACH | 113 |
0027 | 204-06-00100 | Temporary Silt Fencing | LNFT | 62,924 |
0028 | 204-07-00100 | Temporary Stone Construction Entrance | EACH | 8 |
0029 | 302-01-00200 | Class II Base Course (Soil Cement) | CUYD | 10,465.4 |
0030 | 302-01-00300 | Class II Base Course (Crushed Stone) | CUYD | 1,999.2 |
0031 | 302-02-04000 | Class II Base Course (4" Thick) | SQYD | 260,936.7 |
0032 | 302-02-06010 | Class II Base Course (6" Thick) (Soil Cement) | SQYD | 174,686.2 |
0033 | 302-02-08070 | Class II Base Course (8" Thick) (Crushed Stone or Recycled Portland Cement Concrete) | SQYD | 2,590.8 |
0034 | 302-02-10030 | Class II Base Course (10" Thick) (Asphalt Concrete Base on Embankment Layer) | SQYD | 4,692 |
0035 | 304-01-00100 | Lime | TON | 3,681.52 |
0036 | 304-05-00100 | Lime Treatment (Type E) | SQYD | 259,179 |
0037 | 401-02-00100 | Aggregate Surface Course (Adjusted Vehicular Measurement) | CUYD | 239 |
0038 | 402-02-00100 | Mainline Traffic Maintenance Surfacing (Hard) | SQYD | 4,500 |
0039 | 402-03-00100 | Non-Mainline Traffic Maintenance Surfacing (Aggregate) (Vehicular Measurement) | CUYD | 950 |
0040 | 502-01-00100 | Asphalt Concrete | TON | 113,862.3 |
0041 | 502-01-00200 | Asphalt Concrete, Drives, Turnouts and Miscellaneous | TON | 573.3 |
0042 | 509-01-00100 | Milling Asphalt Pavement | SQYD | 12,160 |
0043 | 510-01-00200 | Pavement Patching (12" Minimum Thickness) | SQYD | 146 |
0044 | 510-04-00100 | Pavement Patching | TON | 112 |
0045 | 701-01-01001 | Cross Drain Pipe (24" RCP) | LNFT | 6,337 |
0046 | 701-01-01081 | Cross Drain Pipe (48" RCP) | LNFT | 1,152 |
0047 | 701-01-01100 | Cross Drain Pipe (54" RCP) | LNFT | 198 |
0048 | 701-02-01000 | Cross Drain Pipe Arch (24" Equiv. RCPA) | LNFT | 3,056 |
0049 | 701-02-01060 | Cross Drain Pipe Arch (42" Equiv. RCPA) | LNFT | 488 |
0050 | 701-02-01080 | Cross Drain Pipe Arch (48" Equiv. RCPA) | LNFT | 484 |
0051 | 701-05-01061 | Side Drain Pipe (24" RCP/RPVCP/CPEPDW/CMP) | LNFT | 330 |
0052 | 701-05-01081 | Side Drain Pipe (30" RCP/RPVCP/CPEPDW/CMP) | LNFT | 200 |
0053 | 701-05-02061 | Side Drain Pipe (Erosion) (24" RPVCP/CPEPDW/CMP) | LNFT | 500 |
0054 | 701-06-01040 | Side Drain Pipe Arch (24" Equiv. RCPA/CMPA) | LNFT | 1,476 |
0055 | 701-06-01080 | Side Drain Pipe Arch (36" Equiv. RCPA/CMPA) | LNFT | 72 |
0056 | 701-17-00100 | Trench Excavation Safety Protection (Depth >5 feet) | LNFT | 2,857 |
0057 | 702-03-00100 | Catch Basins (CB-01) | EACH | 54 |
0058 | 702-03-00200 | Catch Basins (CB-02) | EACH | 7 |
0059 | 702-03-00800 | Catch Basins (CB-09) | EACH | 2 |
0060 | 702-04-01000 | Capping Existing Catch Basin or Manhole | EACH | 1 |
0061 | 702-07-00100 | Cross Drain Safety End (Type 1) | EACH | 30 |
0062 | 704-03-00200 | Blocked Out Guard Rail - 31", (6'-3" Post Spacing) | LNFT | 612.6 |
0063 | 704-07-00200 | Guard Rail Transitions (Double Thrie Beam) | LNFT | 100 |
0064 | 704-10-00310 | Guard Rail End Treatment, NCHRP 350 - 31" (TL-3 Flared) | EACH | 4 |
0065 | 705-02-00100 | Combination Mesh & Barbed Wire Fence | LNFT | 36,738 |
0066 | 705-05-00100 | Double Swinging Driveway Gates | DBGT | 2 |
0067 | 705-06-00200 | Chain Link Fence (5-Foot Height) | LNFT | 690 |
0068 | 706-03-00300 | Incidental Concrete Paving (6" Thick) | SQYD | 699.2 |
0069 | 706-03-10000 | Incidental Concrete Paving (Colored)(inch Thick) (10" Thick) | SQYD | 1,428.9 |
0070 | 706-03-10000 | Incidental Concrete Paving (Colored)(inch Thick) (12" Thick) | SQYD | 1,483.7 |
0071 | 707-03-00100 | Combination Concrete Curb and Gutter | LNFT | 4,182.9 |
0072 | 708-01-00100 | Right-of-Way Monument | EACH | 82 |
0073 | 708-02-00100 | Right-of-Way Monument Witness Post | EACH | 82 |
0074 | 710-01-00100 | Flowable Fill | CUYD | 11 |
0075 | 711-01-03000 | Riprap (30 lb, 14" Thick) | SQYD | 8,430 |
0076 | 711-03-00200 | Riprap (10 lb) | TON | 3,970 |
0077 | 711-04-00100 | Geotextile Fabric | SQYD | 17,363 |
0078 | 713-01-00100 | Temporary Signs and Barricades | LUMP | 1 |
0079 | 713-02-00100 | Temporary Pavement Markings (4" Width) | LNFT | 13,065 |
0080 | 713-06-00100 | Temporary Reflectorized Raised Pavement Markers | EACH | 630 |
0081 | 713-11-00100 | Portable Changeable Message Signs | EACH | 4 |
0082 | 716-01-00100 | Mulch (Vegetative) | TON | 274.1 |
0083 | 717-01-00100 | Seeding | LB | 3,601 |
0084 | 718-01-00100 | Fertilizer | LB | 119,840 |
0085 | 722-02-00100 | Project Site Laboratory (Equipped) | EACH | 1 |
0086 | 724-02-00100 | Rumble Strips (Shoulder/Edge) | MILE | 22.617 |
0087 | 725-01-00100 | Temporary Detour Roads | SQYD | 7,111.1 |
0088 | 726-01-00100 | Bedding Material | CUYD | 7,483.7 |
0089 | 727-01-00100 | Mobilization | LUMP | 1 |
0090 | 729-01-00102 | Sign (Type A)(Furnish and Install) | SQFT | 843.2 |
0091 | 729-02-00102 | Sign (Type B)(Furnish and Install) | SQFT | 111.6 |
0092 | 729-04-00102 | Sign (Type D)(Furnish and Install) | SQFT | 30 |
0093 | 729-08-00200 | Mounting (3 1/2" Size Post) | EACH | 13 |
0094 | 729-08-00600 | Mounting (W6 x 12 Size Post) | EACH | 4 |
0095 | 729-16-00200 | Object Marker Assembly (Type 2) | EACH | 102 |
0096 | 729-16-00300 | Object Marker Assembly (Type 3) | EACH | 22 |
0097 | 729-19-00400 | Dead End Road Installations (Type D) | EACH | 1 |
0098 | 729-22-00100 | Square Tubing Post with 2-1/4" Anchor | EACH | 90 |
0099 | 731-02-00100 | Reflectorized Raised Pavement Markers | EACH | 2,304 |
0100 | 732-01-02060 | Plastic Pavement Striping (12" Width) (Thermoplastic 125 mil) | LNFT | 400 |
0101 | 732-01-02080 | Plastic Pavement Striping (24" Width) (Thermoplastic 125 mil) | LNFT | 46 |
0102 | 732-02-02000 | Plastic Pavement Striping (Solid Line) (4" Width) (Thermoplastic 90 mil) | MILE | 23.795 |
0103 | 732-02-02040 | Plastic Pavement Striping (Solid Line) (8" Width) (Thermoplastic 90 mil) | MILE | 0.846 |
0104 | 732-03-02000 | Plastic Pavement Striping (Broken Line) (4" Width) (Thermoplastic 90 mil) | MILE | 11.592 |
0105 | 732-03-02010 | Plastic Pavement Striping (Dotted Line)(4" W)(2' L)(Thermo 90 mil) | MILE | 0.133 |
0106 | 732-03-02030 | Plastic Pavement Striping (Dotted Line)(8" W)(2' L)(Thermo 90 mil) | MILE | 0.521 |
0107 | 732-04-01080 | Plastic Pavement Legends and Symbols (Arrow - Left Turn) | EACH | 4 |
0108 | 732-04-01100 | Plastic Pavement Legends and Symbols (Arrow - Right Turn) | EACH | 4 |
0109 | 732-04-01121 | Plastic Pavement Legends and Symbols (U-Turn) | EACH | 14 |
0110 | 732-04-15020 | Plastic Pavement Legends and Symbols (ONLY) | EACH | 4 |
0111 | 735-01-00100 | Mailboxes | EACH | 3 |
0112 | 735-02-00100 | Mailbox Supports (Single) | EACH | 3 |
0113 | 740-01-00100 | Construction Layout | LUMP | 1 |
0114 | 804-01-00300 | Precast Concrete Piles (16") | LNFT | 3,216 |
0115 | 804-01-00600 | Precast Concrete Piles (24") | LNFT | 3,760 |
0116 | 804-05-00300 | Precast Concrete Test Piles (16") | EACH | 1 |
0117 | 804-05-00600 | Precast Concrete Test Piles (24") | EACH | 1 |
0118 | 804-09-00300 | Static Load Test (Precast Concrete Piles (16")) | EACH | 1 |
0119 | 804-09-00600 | Static Load Test (Precast Concrete Piles (24")) | EACH | 1 |
0120 | 804-14-00100 | Dynamic Monitoring Assistance | EACH | 14 |
0121 | 804-15-00100 | Dynamic Monitoring Instrumentation | LUMP | 1 |
0122 | 805-01-00200 | Class A1 Concrete (Deck) | CUYD | 1,000.44 |
0123 | 805-01-00300 | Class A1 Concrete (Bent Cap) | CUYD | 349.08 |
0124 | 805-08-00400 | Precast-Prestressed Concrete Girders (Type III) | LNFT | 4,170 |
0125 | 805-15-00200 | Reinforced Concrete Box Culverts (Precast) (5' x 4') | LNFT | 928 |
0126 | 805-15-00700 | Reinforced Concrete Box Culverts (Precast) (6' x 5') | LNFT | 1,344 |
0127 | 805-17-00100 | Reinforced Concrete Box Culvert Headwall (2 - 48" RCP, 12.2 CuYd, 734 lbs.) | EACH | 2 |
0128 | 805-17-00100 | Reinforced Concrete Box Culvert Headwall (2 - 48" RCP, 12.7 CuYd, 680 lbs.) | EACH | 2 |
0129 | 805-17-00100 | Reinforced Concrete Box Culvert Headwall (2 - 48" RCP, 18.0 CuYd, 964 lbs.) | EACH | 2 |
0130 | 805-17-00100 | Reinforced Concrete Box Culvert Headwall (2 - 5' x 4' RCB, 6.6 CUYD, 530 lbs.) | EACH | 2 |
0131 | 805-17-00100 | Reinforced Concrete Box Culvert Headwall (2 - 5' x 4' RCB, 8.1 CUYD, 658 lbs.) | EACH | 2 |
0132 | 805-17-00100 | Reinforced Concrete Box Culvert Headwall (2 - 6' x 5' RCB, 11.1 CUYD, 898 lbs.) | EACH | 2 |
0133 | 805-17-00100 | Reinforced Concrete Box Culvert Headwall (2 - 6' x 5' RCB, 8.9 CUYD, 635 lbs.) | EACH | 4 |
0134 | 805-17-00100 | Reinforced Concrete Box Culvert Headwall (54" RCP, 12.6 CuYd, 781 lbs.) | EACH | 2 |
0135 | 805-18-00100 | Concrete Finish (Class 2 Rubbed Finish) | SQFT | 16,522 |
0136 | 805-18-00200 | Concrete Finish (Class 3 Special Finish) | SQFT | 16,522 |
0137 | 806-01-00100 | Deformed Reinforcing Steel | LB | 337,440 |
0138 | 807-02-00100 | Structural Metalwork (Anchor Bolts) (ASTM A307 Grade A Steel) | LUMP | 1 |
0139 | 810-01-00120 | Concrete Bridge Railing (36 inch Height) | LNFT | 1,824 |
0140 | 813-01-00100 | Concrete Approach Slabs (Cast-in-Place) | SQFT | 6,134 |
0141 | 814-02-00100 | Elastomeric Bearing Pads (Reinforced) | SFIN | 486 |
0142 | 815-02-00200 | Sealed Expansion Joint (End Dams and Preformed Silicone Seal) | LNFT | 152 |
0143 | NS-500-00240 | Sawing and Sealing Transverse Joints in Asphalt Concrete Overlay | LNFT | 324 |
0144 | NS-500-00260 | Sawcuts in Asphalt Concrete Lifts | LNFT | 760 |
0145 | NS-500-00340 | Saw Cutting Asphalt Concrete Pavement | INLF | 10,073 |
0146 | NS-704-00001 | High Tension Cable Barrier | LNFT | 2,215 |
0147 | NS-704-00002 | Cable Barrier Gated End Terminal | EACH | 2 |
0148 | NS-704-00003 | Concrete Strip | SQYD | 2,215 |
0149 | 202-02-00050 | Removal of Mobile Home, Roof Cover, Concrete Slabs and MoDAD (Sta. 127+60, Rt.) | LUMP | 1 |
0150 | 202-02-05000 | Removal of Building with Lean-To (Metal) (Sta. 142+13, Rt.) (1,036 SF) | EACH | 1 |
0151 | 202-02-38200 | Removal of Signs (4'X4') (Sta. 389+25, Lt.) | EACH | 1 |
0152 | 705-01-00100 | Barbed Wire Fence | LNFT | 393 |