Line Number | Item | Description | Unit | Quantity |
0001 | 201-01-00100 | Clearing and Grubbing | LUMP | 1 |
0002 | 202-01-00100 | Removal of Structures and Obstructions | LUMP | 1 |
0003 | 202-02-02000 | Removal of Asphalt Drives | SQYD | 598 |
0004 | 202-02-02020 | Removal of Asphalt Pavement | SQYD | 6,125.3 |
0005 | 202-02-03000 | Removal of Base – Soil Cement, Asphalt, or BCS | SQYD | 6,738.9 |
0006 | 202-02-06100 | Removal of Concrete Walks and Drives | SQYD | 399 |
0007 | 202-02-32500 | Removal of Portland Cement Concrete Pavement | SQYD | 613.6 |
0008 | 202-02-38240 | Removal of Signs and Supports | EACH | 22 |
0009 | 202-02-40100 | Removal of Traffic Signal Equipment | LUMP | 1 |
0010 | 202-02-40120 | Removal of Traffic Detectors and Associated Equipment | LUMP | 1 |
0011 | 203-01-00100 | General Excavation | CUYD | 12,203 |
0012 | 203-03-00100 | Embankment | CUYD | 693 |
0013 | 204-05-00100 | Temporary Sediment Check Dams (Hay) | EACH | 104 |
0014 | 204-06-00100 | Temporary Silt Fencing | LNFT | 4,873 |
0015 | 302-02-12000 | Class II Base Course (12" Thick) | SQYD | 10,371.8 |
0016 | 302-02-12030 | Class II Base Course (12" Thick) (Asphalt Concrete Base on Embankment Layer) | SQYD | 4,196.5 |
0017 | 304-01-00100 | Lime | TON | 206.49 |
0018 | 304-05-00100 | Lime Treatment (Type E) | SQYD | 14,570 |
0019 | 401-02-00100 | Aggregate Surface Course (Adjusted Vehicular Measurement) | CUYD | 6 |
0020 | 402-03-00100 | Non-Mainline Traffic Maintenance Surfacing (Aggregate) (Vehicular Measurement) | CUYD | 200 |
0021 | 502-01-00100 | Asphalt Concrete | TON | 3,469.9 |
0022 | 502-01-00200 | Asphalt Concrete, Drives, Turnouts and Miscellaneous | TON | 85.5 |
0023 | 509-01-00100 | Milling Asphalt Pavement | SQYD | 432 |
0024 | 509-02-00100 | Contractor Retained Reclaimed Asphalt Pavement | CUYD | -24 |
0025 | 510-01-00300 | Pavement Patching (18" Minimum Thickness) | SQYD | 24 |
0026 | 510-02-00100 | Pavement Widening (18" Minimum Thickness) | SQYD | 48 |
0027 | 701-02-01000 | Cross Drain Pipe Arch (24" Equiv. RCPA) | LNFT | 108 |
0028 | 701-03-01022 | Storm Drain Pipe (18" RCP/RPVCP) | LNFT | 202 |
0029 | 701-03-01042 | Storm Drain Pipe (24" RCP/RPVCP) | LNFT | 78 |
0030 | 701-04-01020 | Storm Drain Pipe Arch (18" Equiv. RCPA) | LNFT | 66 |
0031 | 701-05-01061 | Side Drain Pipe (24" RCP/RPVCP/CPEPDW/CMP) | LNFT | 144 |
0032 | 701-06-01020 | Side Drain Pipe Arch (18" Equiv. RCPA/CMPA) | LNFT | 42 |
0033 | 701-09-00100 | Pipe Fittings | EACH | 1 |
0034 | 701-15-00100 | Concrete Collar | EACH | 1 |
0035 | 701-17-00100 | Trench Excavation Safety Protection (Depth >5 feet) | LNFT | 440 |
0036 | 702-03-00100 | Catch Basins (CB-01) | EACH | 5 |
0037 | 702-07-00100 | Cross Drain Safety End (Type 1) | EACH | 2 |
0038 | 705-06-00200 | Chain Link Fence (5-Foot Height) | LNFT | 750 |
0039 | 706-02-00200 | Concrete Drive (6" Thick) | SQYD | 311.7 |
0040 | 706-02-00400 | Concrete Drive (10" Thick) | SQYD | 316.1 |
0041 | 707-01-00200 | Concrete Curb (Barrier) | LNFT | 1,550 |
0042 | 708-01-00100 | Right-of-Way Monument | EACH | 29 |
0043 | 713-01-00100 | Temporary Signs and Barricades | LUMP | 1 |
0044 | 713-02-00500 | Temporary Pavement Markings (24" Width) | LNFT | 45 |
0045 | 713-04-01000 | Temporary Pavement Markings (Solid Line) (4" Width) | MILE | 1.039 |
0046 | 713-06-00100 | Temporary Reflectorized Raised Pavement Markers | EACH | 132 |
0047 | 717-01-00100 | Seeding | LB | 76 |
0048 | 718-01-00100 | Fertilizer | LB | 3,737 |
0049 | 720-01-01000 | Erosion Control System (Slope Protection) (Type A) | SQYD | 141 |
0050 | 720-01-02000 | Erosion Control System, Flexible (Channel Liner) (Type C) | SQYD | 11 |
0051 | 724-02-00100 | Rumble Strips (Shoulder/Edge) | MILE | 1.228 |
0052 | 725-01-00100 | Temporary Detour Roads | SQYD | 1,746 |
0053 | 726-01-00100 | Bedding Material | CUYD | 51.9 |
0054 | 727-01-00100 | Mobilization | LUMP | 1 |
0055 | 729-01-00100 | Sign (Type A) | SQFT | 204.2 |
0056 | 729-16-00200 | Object Marker Assembly (Type 2) | EACH | 4 |
0057 | 729-19-00400 | Dead End Road Installations (Type D) | EACH | 1 |
0058 | 729-22-00200 | Square Tubing Post with 2-1/4" Omni-Directional Anchor | EACH | 26 |
0059 | 731-02-00100 | Reflectorized Raised Pavement Markers | EACH | 137 |
0060 | 732-01-02080 | Plastic Pavement Striping (24" Width) (Thermoplastic 125 mil) | LNFT | 74 |
0061 | 732-02-02000 | Plastic Pavement Striping (Solid Line) (4" Width) (Thermoplastic 90 mil) | MILE | 1.935 |
0062 | 732-02-02040 | Plastic Pavement Striping (Solid Line) (8" Width) (Thermoplastic 90 mil) | MILE | 0.313 |
0063 | 732-03-02030 | Plastic Pavement Striping (Dotted Line)(8" W)(2' L)(Thermo 90 mil) | MILE | 0.112 |
0064 | 732-04-01040 | Plastic Pavement Legends and Symbols (Arrow - Double) | EACH | 1 |
0065 | 732-04-01080 | Plastic Pavement Legends and Symbols (Arrow - Left Turn) | EACH | 11 |
0066 | 732-04-01100 | Plastic Pavement Legends and Symbols (Arrow - Right Turn) | EACH | 2 |
0067 | 732-04-19020 | Plastic Pavement Legends and Symbols (SCHOOL ZONE) | EACH | 2 |
0068 | 732-05-00100 | Removal of Existing Markings | MILE | 0.933 |
0069 | 736-01-00100 | Trenching and Backfilling | LNFT | 765 |
0070 | 736-03-00100 | Jacking or Boring | LNFT | 747 |
0071 | 736-04-01300 | Signal Pole (30 foot Steel Strain Pole) | EACH | 4 |
0072 | 736-05-30000 | Signal Heads (3 Section, 12 inch Led Lens, R, Y, G) | EACH | 6 |
0073 | 736-05-31001 | Signal Heads (3 Sec, 12 inch Led Lens, LT. R, LT. Y, LT. G) | EACH | 2 |
0074 | 736-05-41000 | Signal Heads (4 Section, 12" Led Lens, R, Y, LT. G, G) | EACH | 1 |
0075 | 736-05-41200 | Signal Heads (4 Section, 12 inch Led Lens, LT. R, LT. Y, FLT. Y, LT. G) | EACH | 2 |
0076 | 736-05-55000 | Signal Heads (5 Section, 12 inch Led Lens, R, Y, RT. Y, G, RT. G) | EACH | 1 |
0077 | 736-06-00100 | Signal Service | EACH | 1 |
0078 | 736-08-00102 | Signal Controller (980 ATC, Type 2)(Furnish & Install) | EACH | 1 |
0079 | 736-09-00100 | Loop Detector | LNFT | 120 |
0080 | 736-10-00200 | Underground Junction Box (Type E) | EACH | 3 |
0081 | 736-10-00300 | Underground Junction Box (Type F) | EACH | 5 |
0082 | 736-10-00400 | Underground Junction Box (Type G) | EACH | 1 |
0083 | 736-11-00050 | Conduit (1/2" HDPE, Schedule 80) | LNFT | 40 |
0084 | 736-11-00200 | Conduit (2" HDPE, Schedule 80) | LNFT | 1,427 |
0085 | 736-11-00300 | Conduit (3" HDPE, Schedule 80) | LNFT | 190 |
0086 | 736-12-00000 | Conductor (2c, Loop Lead in, imsa 50-2, #14 awg, Twisted Pair) | LNFT | 1,402 |
0087 | 736-12-03006 | Conductor (3c, 6 gauge / #6 awg) | LNFT | 65 |
0088 | 736-12-06014 | Conductor (6c, #14 awg) | LNFT | 33 |
0089 | 736-12-10014 | Conductor (10c, #14 awg) | LNFT | 1,731 |
0090 | 736-15-03600 | Signal Support (Foundation, 36 inch Minimum Diameter) | EACH | 4 |
0091 | 736-17-00000 | Video Detection Cabinet Components | EACH | 1 |
0092 | 736-18-00000 | Video Detection Camera | EACH | 4 |
0093 | 736-19-00000 | Video Camera Cable | LNFT | 810 |
0094 | 736-25-00002 | Support Cable (Span) (3/8 inch) | LNFT | 226 |
0095 | 740-01-00100 | Construction Layout | LUMP | 1 |
0096 | NS-500-00340 | Saw Cutting Asphalt Concrete Pavement | INLF | 24,968 |
0097 | NS-600-00220 | Saw Cutting Portland Cement Concrete Pavement | INLF | 7,695 |
0098 | NS-736-00001 | GPS | EACH | 1 |
0099 | NS-736-00130 | TS-2 Traffic Signal Cabinet (Ground Mounted) | EACH | 1 |
0100 | 732-03-02010 | Plastic Pavement Striping (Dotted Line)(4" W)(2' L)(Thermo 90 mil) | MILE | 0.03 |