Line Number | Item | Description | Unit | Quantity |
0001 | 201-01-00100 | Clearing and Grubbing | LUMP | 1 |
0002 | 202-02-06080 | Removal of Concrete Combination Curb and Gutter | LNFT | 130.1 |
0003 | 202-02-14500 | Removal of Guard Rail | LNFT | 506 |
0004 | 202-02-32100 | Removal of Pipe (Cross Drain) (24" CMP) | LNFT | 40 |
0005 | 202-02-32120 | Removal of Pipe (Side Drain) (30" RCP/CMPA) | LNFT | 72 |
0006 | 203-05-00100 | Excavation and Embankment | LUMP | 1 |
0007 | 204-05-00100 | Temporary Sediment Check Dams (Hay) | EACH | 22 |
0008 | 204-06-00100 | Temporary Silt Fencing | LNFT | 650 |
0009 | 402-03-00100 | Non-Mainline Traffic Maintenance Surfacing (Aggregate) (Vehicular Measurement) | CUYD | 30 |
0010 | 501-02-00100 | Thin Asphalt Concrete (Coarse Mix) | TON | 2,459.1 |
0011 | 502-01-00200 | Asphalt Concrete, Drives, Turnouts and Miscellaneous | TON | 53 |
0012 | 509-01-00100 | Milling Asphalt Pavement | SQYD | 1,038 |
0013 | 509-02-00100 | Contractor Retained Reclaimed Asphalt Pavement | CUYD | -15 |
0014 | 510-01-00260 | Pavement Patching (16 inch Minimum Thickness) | SQYD | 192 |
0015 | 510-02-00100 | Pavement Widening (15" THICK) | SQYD | 85 |
0016 | 701-02-01000 | Cross Drain Pipe Arch (24" Equiv. RCPA) | LNFT | 44 |
0017 | 701-03-01042 | Storm Drain Pipe (24" RCP/RPVCP) | LNFT | 32 |
0018 | 701-05-02101 | Side Drain Pipe (Erosion) (36" RPVCP/CPEPDW/CMP) | LNFT | 192 |
0019 | 701-17-00100 | Trench Excavation Safety Protection (Depth >5 feet) | LNFT | 268 |
0020 | 702-03-00100 | Catch Basins (CB-01) | EACH | 1 |
0021 | 702-08-00100 | Side Drain Safety End (Type 1) | EACH | 1 |
0022 | 704-01-01020 | Guard Rail (Single Thrie Beam) (6'-3" post spacing) | LNFT | 125 |
0023 | 704-03-00200 | Blocked Out Guard Rail - 31", (6'-3" Post Spacing) | LNFT | 262.7 |
0024 | 704-07-00200 | Guard Rail Transitions (Double Thrie Beam) | LNFT | 100 |
0025 | 704-10-00205 | Guard Rail End Treatment, MASH, (TL-3 Tangent) | EACH | 3 |
0026 | 704-10-00310 | Guard Rail End Treatment, NCHRP 350 - 31" (TL-3 Flared) | EACH | 1 |
0027 | 707-03-00100 | Combination Concrete Curb and Gutter | LNFT | 144.6 |
0028 | 711-01-04020 | Riprap (55 lb, 24" Thick) | SQYD | 422 |
0029 | 711-01-05000 | Riprap (130 lb, 24" Thick) | SQYD | 313 |
0030 | 711-04-00100 | Geotextile Fabric | SQYD | 790 |
0031 | 713-01-00100 | Temporary Signs and Barricades | LUMP | 1 |
0032 | 713-03-01000 | Temporary Pavement Markings (Broken Line) (4" Width) (4' Length) | MILE | 0.232 |
0033 | 713-03-02000 | Temporary Pavement Markings (Broken Line) (4" Width) (10' Length) | MILE | 3.522 |
0034 | 713-04-01000 | Temporary Pavement Markings (Solid Line) (4" Width) | MILE | 8.773 |
0035 | 713-05-00100 | Temporary Pavement Legends & Symbols (Arrow) | EACH | 31 |
0036 | 713-05-00300 | Temporary Pavement Legends & Symbols (ONLY) | EACH | 5 |
0037 | 724-02-00100 | Rumble Strips (Shoulder/Edge) | MILE | 3.7 |
0038 | 726-01-00100 | Bedding Material | CUYD | 30.9 |
0039 | 727-01-00100 | Mobilization | LUMP | 1 |
0040 | 729-16-00200 | Object Marker Assembly (Type 2) | EACH | 4 |
0041 | 729-16-00300 | Object Marker Assembly (Type 3) | EACH | 6 |
0042 | 731-02-00100 | Reflectorized Raised Pavement Markers | EACH | 543 |
0043 | 732-01-01040 | Plastic Pavement Striping (8" Width) (Thermoplastic 90 mil) | LNFT | 179 |
0044 | 732-01-02080 | Plastic Pavement Striping (24" Width) (Thermoplastic 125 mil) | LNFT | 40 |
0045 | 732-02-02000 | Plastic Pavement Striping (Solid Line) (4" Width) (Thermoplastic 90 mil) | MILE | 8.773 |
0046 | 732-03-02000 | Plastic Pavement Striping (Broken Line) (4" Width) (Thermoplastic 90 mil) | MILE | 3.522 |
0047 | 732-03-02010 | Plastic Pavement Striping (Dotted Line)(4" W)(2' L)(Thermo 90 mil) | MILE | 0.004 |
0048 | 732-04-01080 | Plastic Pavement Legends and Symbols (Arrow - Left Turn) | EACH | 31 |
0049 | 732-04-15020 | Plastic Pavement Legends and Symbols (ONLY) | EACH | 5 |
0050 | 732-05-00100 | Removal of Existing Markings | MILE | 2.202 |
0051 | 735-01-00100 | Mailboxes | EACH | 26 |
0052 | 735-02-00100 | Mailbox Supports (Single) | EACH | 26 |
0053 | 736-01-00100 | Trenching and Backfilling | LNFT | 30 |
0054 | 736-04-10500 | Signal Pole (Single Mast Arm, 50ft) | EACH | 1 |
0055 | 736-05-10000 | Signal Heads (1 Section, 12 inch Led Lens, R) | EACH | 4 |
0056 | 736-05-10005 | Signal Heads (1 Section, 12 inch Led Lens, Y) | EACH | 4 |
0057 | 736-06-00100 | Signal Service | EACH | 1 |
0058 | 736-10-00300 | Underground Junction Box (Type F) | EACH | 2 |
0059 | 736-11-00200 | Conduit (2" HDPE, Schedule 80) | LNFT | 60 |
0060 | 736-12-03006 | Conductor (3c, 6 gauge / #6 awg) | LNFT | 50 |
0061 | 736-12-04012 | Conductor (4c, #12 awg) | LNFT | 488 |
0062 | 736-15-03600 | Signal Support (Foundation, 36 inch Minimum Diameter) | EACH | 1 |
0063 | 736-24-00000 | Flashing Switch Assembly For Beacons | EACH | 1 |
0064 | 739-01-00100 | Hydro-Seeding | ACRE | 0.81 |
0065 | 740-01-00100 | Construction Layout | LUMP | 1 |
0066 | NS-600-00220 | Saw Cutting Portland Cement Concrete Pavement | INLF | 1,561 |