Line Number | Item | Description | Unit | Quantity |
0001 | 201-01-00100 | Clearing and Grubbing | LUMP | 1 |
0002 | 202-02-02020 | Removal of Asphalt Pavement | SQYD | 15,785 |
0003 | 202-02-06060 | Removal of Concrete Catch Basin | EACH | 1 |
0004 | 202-02-06100 | Removal of Concrete Walks and Drives | SQYD | 621 |
0005 | 202-02-06140 | Removal of Curbs (Concrete) | LNFT | 35 |
0006 | 202-02-32100 | Removal of Pipe (Cross Drain) . | LNFT | 59 |
0007 | 202-02-38260 | Removal of Sign Support Footings | EACH | 3 |
0008 | 202-02-40100 | Removal of Traffic Signal Equipment | LUMP | 1 |
0009 | 202-03-38000 | Relocation of Sign . | EACH | 15 |
0010 | 203-05-00100 | Excavation and Embankment | LUMP | 1 |
0011 | 502-01-00100 | Asphalt Concrete | TON | 27,521.2 |
0012 | 502-01-00200 | Asphalt Concrete, Drives, Turnouts and Miscellaneous | TON | 175 |
0013 | 509-01-00100 | Milling Asphalt Pavement | SQYD | 5,499 |
0014 | 509-02-00100 | Contractor Retained Reclaimed Asphalt Pavement | CUYD | -230 |
0015 | 510-01-00300 | Pavement Patching (18" Minimum Thickness) | SQYD | 500 |
0016 | 701-01-01021 | Cross Drain Pipe (30" RCP) | LNFT | 24 |
0017 | 701-01-01041 | Cross Drain Pipe (36" RCP) | LNFT | 15 |
0018 | 701-02-01060 | Cross Drain Pipe Arch (42" Equiv. RCPA) | LNFT | 36 |
0019 | 701-02-01080 | Cross Drain Pipe Arch (48" Equiv. RCPA) | LNFT | 80 |
0020 | 701-03-01022 | Storm Drain Pipe (18" RCP/RPVCP) | LNFT | 386 |
0021 | 701-15-00100 | Concrete Collar | EACH | 4 |
0022 | 702-02-00300 | Manholes (R-CB-11 MOD) | EACH | 1 |
0023 | 702-03-00100 | Catch Basins (CB-01) | EACH | 8 |
0024 | 702-03-00200 | Catch Basins (CB-02) | EACH | 3 |
0025 | 706-02-00200 | Concrete Drive (6" Thick) | SQYD | 32 |
0026 | 706-02-00300 | Concrete Drive (8" Thick) | SQYD | 526 |
0027 | 706-03-00100 | Incidental Concrete Paving (4" Thick) | SQYD | 145 |
0028 | 707-01-00300 | Concrete Curb (Mountable) | LNFT | 505 |
0029 | 713-01-00100 | Temporary Signs and Barricades | LUMP | 1 |
0030 | 713-02-00300 | Temporary Pavement Markings (8" Width) | LNFT | 16,284 |
0031 | 713-02-00500 | Temporary Pavement Markings (24" Width) | LNFT | 1,092 |
0032 | 713-04-01000 | Temporary Pavement Markings (Solid Line) (4" Width) | MILE | 11.44 |
0033 | 713-05-00100 | Temporary Pavement Legends & Symbols (Arrow) | EACH | 112 |
0034 | 717-01-00100 | Seeding | LB | 40 |
0035 | 718-01-00100 | Fertilizer | LB | 1,969 |
0036 | 724-02-00100 | Rumble Strips (Shoulder/Edge) | MILE | 3.5 |
0037 | 726-01-00100 | Bedding Material | CUYD | 138 |
0038 | 727-01-00100 | Mobilization | LUMP | 1 |
0039 | 729-01-00102 | Sign (Type A)(Furnish and Install) | SQFT | 121.7 |
0040 | 729-02-00100 | Sign (Type B) | SQFT | 151 |
0041 | 729-21-00100 | U-Channel Post | EACH | 20 |
0042 | 731-02-00100 | Reflectorized Raised Pavement Markers | EACH | 1,340 |
0043 | 732-01-01040 | Plastic Pavement Striping (8" Width) (Thermoplastic 90 mil) | LNFT | 4,431 |
0044 | 732-01-01080 | Plastic Pavement Striping (24" Width) (Thermoplastic 90 mil) | LNFT | 510 |
0045 | 732-01-02080 | Plastic Pavement Striping (24" Width) (Thermoplastic 125 mil) | LNFT | 36 |
0046 | 732-02-02000 | Plastic Pavement Striping (Solid Line) (4" Width) (Thermoplastic 90 mil) | MILE | 5.72 |
0047 | 732-03-02030 | Plastic Pavement Striping (Dotted Line)(8" W)(2' L)(Thermo 90 mil) | MILE | 0.7 |
0048 | 732-04-01080 | Plastic Pavement Legends and Symbols (Arrow - Left Turn) | EACH | 4 |
0049 | 732-04-01100 | Plastic Pavement Legends and Symbols (Arrow - Right Turn) | EACH | 4 |
0050 | 732-04-01120 | Plastic Pavement Legends and Symbols (Arrow - Merge) | EACH | 30 |
0051 | 732-04-01121 | Plastic Pavement Legends and Symbols (U-Turn) | EACH | 18 |
0052 | 732-05-00100 | Removal of Existing Markings | MILE | 2.27 |
0053 | 735-01-00100 | Mailboxes | EACH | 5 |
0054 | 735-02-00100 | Mailbox Supports (Single) | EACH | 5 |
0055 | 736-01-00100 | Trenching and Backfilling | LNFT | 1,355 |
0056 | 736-03-00100 | Jacking or Boring | LNFT | 660 |
0057 | 736-04-00001 | Signal Pole (Pedestal Pole) | EACH | 1 |
0058 | 736-04-01300 | Signal Pole (30 foot Steel Strain Pole) | EACH | 2 |
0059 | 736-04-10250 | Signal Pole (Single Mast Arm, 25ft) | EACH | 1 |
0060 | 736-04-10300 | Signal Pole (Single Mast Arm, 30ft) | EACH | 1 |
0061 | 736-04-24025 | Signal Pole (Dual Mast Arm, 40ft-Arm 1, 25ft-Arm 2) | EACH | 1 |
0062 | 736-04-24535 | Signal Pole (Dual Mast Arm, 45ft-Arm 1, 35ft-Arm 2) | EACH | 1 |
0063 | 736-05-10000 | Signal Heads (1 Section, 12 inch Led Lens, R) | EACH | 2 |
0064 | 736-05-10005 | Signal Heads (1 Section, 12 inch Led Lens, Y) | EACH | 4 |
0065 | 736-05-30000 | Signal Heads (3 Section, 12 inch Led Lens, R, Y, G) | EACH | 7 |
0066 | 736-05-31001 | Signal Heads (3 Sec, 12 inch Led Lens, LT. R, LT. Y, LT. G) | EACH | 7 |
0067 | 736-06-00200 | Signal Service (Existing Pole) | EACH | 3 |
0068 | 736-06-00500 | Signal Service Pedestal Disconnect | EACH | 2 |
0069 | 736-08-00102 | Signal Controller (980 ATC, Type 2)(Furnish & Install) | EACH | 2 |
0070 | 736-09-00100 | Loop Detector | LNFT | 1,745 |
0071 | 736-10-00300 | Underground Junction Box (Type F) | EACH | 13 |
0072 | 736-10-00400 | Underground Junction Box (Type G) | EACH | 2 |
0073 | 736-11-00050 | Conduit (1/2" HDPE, Schedule 80) | LNFT | 40 |
0074 | 736-11-00100 | Conduit (1" HDPE, Schedule 80) | LNFT | 1,650 |
0075 | 736-11-00200 | Conduit (2" HDPE, Schedule 80) | LNFT | 835 |
0076 | 736-11-00300 | Conduit (3" HDPE, Schedule 80) | LNFT | 415 |
0077 | 736-12-00000 | Conductor (2c, Loop Lead in, imsa 50-2, #14 awg, Twisted Pair) | LNFT | 2,850 |
0078 | 736-12-03006 | Conductor (3c, 6 gauge / #6 awg) | LNFT | 480 |
0079 | 736-12-06014 | Conductor (6c, #14 awg) | LNFT | 1,110 |
0080 | 736-12-10014 | Conductor (10c, #14 awg) | LNFT | 670 |
0081 | 736-15-02400 | Signal Support (Foundation, 24 inch Minimum Diameter) | EACH | 1 |
0082 | 736-15-03600 | Signal Support (Foundation, 36 inch Minimum Diameter) | EACH | 6 |
0083 | 736-24-00000 | Flashing Switch Assembly For Beacons | EACH | 1 |
0084 | 736-26-00002 | Guy Cable (3/8 inch) | LNFT | 200 |
0085 | 737-04-00001 | Painted Curbs and Islands | SQYD | 90 |
0086 | 740-01-00100 | Construction Layout | LUMP | 1 |
0087 | 805-13-00100 | Reinforced Concrete Box Culverts (Cast-In-Place or Precast) (4' x 4') | LNFT | 24 |
0088 | 805-13-00200 | Reinforced Concrete Box Culverts (Cast-In-Place or Precast) (5' x 4') | LNFT | 16 |
0089 | NS-500-00340 | Saw Cutting Asphalt Concrete Pavement | INLF | 198,638 |
0090 | NS-600-00220 | Saw Cutting Portland Cement Concrete Pavement | INLF | 4,077 |
0091 | NS-736-00001 | GPS | EACH | 2 |
0092 | NS-736-00130 | TS-2 Traffic Signal Cabinet (Ground Mounted) | EACH | 2 |