Line Number | Item | Description | Unit | Quantity |
0001 | 202-02-00010 | Removal of LIGHT POLE AND APRON | EACH | 68 |
0002 | 202-02-00010 | Removal of Safety end treatment | EACH | 2 |
0003 | 202-02-00050 | Removal of Conduit with Conductor | LUMP | 1 |
0004 | 202-02-02020 | Removal of Asphalt Pavement | SQYD | 45,407.8 |
0005 | 202-02-03000 | Removal of Base – Soil Cement, Asphalt, or BCS | SQYD | 45,407.8 |
0006 | 202-02-06060 | Removal of Concrete Catch Basin | EACH | 15 |
0007 | 202-02-06080 | Removal of Concrete Combination Curb and Gutter | LNFT | 595 |
0008 | 202-02-06100 | Removal of Concrete Walks and Drives | SQYD | 341 |
0009 | 202-02-06140 | Removal of Curbs (Concrete) | LNFT | 1,613 |
0010 | 202-02-14500 | Removal of Guard Rail | LNFT | 573 |
0011 | 202-02-26300 | Removal of Median / Island | SQYD | 425 |
0012 | 202-02-32100 | Removal of Pipe (Cross Drain) 18" RCP | LNFT | 210 |
0013 | 202-02-32500 | Removal of Portland Cement Concrete Pavement | SQYD | 65 |
0014 | 202-02-40100 | Removal of Traffic Signal Equipment | LUMP | 1 |
0015 | 203-01-00100 | General Excavation | CUYD | 9,249 |
0016 | 203-03-00100 | Embankment | CUYD | 14,602 |
0017 | 204-02-00100 | Temporary Hay Bales | EACH | 420 |
0018 | 204-05-00100 | Temporary Sediment Check Dams (Hay) | EACH | 104 |
0019 | 204-06-00100 | Temporary Silt Fencing | LNFT | 8,509 |
0020 | 302-02-08510 | Class II Base Course (8-1/2" Thick) (Soil Cement) | SQYD | 61,620.4 |
0021 | 304-01-00100 | Lime | TON | 202.23 |
0022 | 304-04-00300 | Lime Treatment (Type D) (10" Thick) | SQYD | 15,405 |
0023 | 305-01-03020 | Subgrade Layer (10" Thick) (Treated) | SQYD | 61,620 |
0024 | 401-01-00100 | Aggregate Surface Course (Net Section) Limestone | CUYD | 98.4 |
0025 | 401-02-00100 | Aggregate Surface Course (Adjusted Vehicular Measurement) | CUYD | 52 |
0026 | 402-03-00100 | Non-Mainline Traffic Maintenance Surfacing (Aggregate) (Vehicular Measurement) | CUYD | 781.4 |
0027 | 502-01-00100 | Asphalt Concrete | TON | 24,588.5 |
0028 | 502-01-00200 | Asphalt Concrete, Drives, Turnouts and Miscellaneous | TON | 945.6 |
0029 | 502-03-00300 | Asphalt Concrete (6" Thick) | SQYD | 386 |
0030 | 502-04-00100 | Asphalt Concrete (SMA) Wearing Course | TON | 18,354.7 |
0031 | 509-01-00100 | Milling Asphalt Pavement | SQYD | 180,985 |
0032 | 509-02-00100 | Contractor Retained Reclaimed Asphalt Pavement | CUYD | -8,144 |
0033 | 510-01-00200 | Pavement Patching (12" Minimum Thickness) | SQYD | 696 |
0034 | 510-02-00100 | Pavement Widening 24" Minimum Thickness | SQYD | 24.2 |
0035 | 601-01-00500 | Portland Cement Concrete Pavement (10" Thick) | SQYD | 2,914.4 |
0036 | 601-01-00700 | Portland Cement Concrete Pavement (11" Thick) | SQYD | 174.7 |
0037 | 701-03-01002 | Storm Drain Pipe (15" RCP/RPVCP) | LNFT | 1,212 |
0038 | 701-03-01022 | Storm Drain Pipe (18" RCP/RPVCP) | LNFT | 3,912 |
0039 | 701-03-01042 | Storm Drain Pipe (24" RCP/RPVCP) | LNFT | 866 |
0040 | 701-05-01046 | Side Drain Pipe (18" RCP/RPVCP) | LNFT | 1,439 |
0041 | 701-05-01062 | Side Drain Pipe (24" RCP/RPVCP/CMP) | LNFT | 328 |
0042 | 701-06-01040 | Side Drain Pipe Arch (24" Equiv. RCPA/CMPA) | LNFT | 109 |
0043 | 701-15-00100 | Concrete Collar | EACH | 40 |
0044 | 701-17-00100 | Trench Excavation Safety Protection (Depth >5 feet) | LNFT | 7,852 |
0045 | 702-02-00100 | Manholes (MH-06) | EACH | 1 |
0046 | 702-03-00100 | Catch Basins (CB-01) | EACH | 45 |
0047 | 702-03-00200 | Catch Basins (CB-02) | EACH | 2 |
0048 | 702-03-00500 | Catch Basins (CB-06) | EACH | 54 |
0049 | 702-03-00600 | Catch Basins (CB-07) | EACH | 6 |
0050 | 702-04-00100 | Adjusting Manholes | EACH | 4 |
0051 | 702-04-00210 | Convert Catch Basins to Manholes | EACH | 6 |
0052 | 702-08-00100 | Side Drain Safety End (Type 1) | EACH | 1 |
0053 | 702-08-00200 | Side Drain Safety End (Type 2) | EACH | 1 |
0054 | 704-03-00200 | Blocked Out Guard Rail - 31", (6'-3" Post Spacing) | LNFT | 262.5 |
0055 | 704-06-00200 | Guard Rail Bridge Attachments (Single Thrie Beam) | LNFT | 50 |
0056 | 704-07-00200 | Guard Rail Transitions (Double Thrie Beam) | LNFT | 100 |
0057 | 704-10-00205 | Guard Rail End Treatment, MASH, (TL-3 Tangent) | EACH | 2 |
0058 | 704-10-00310 | Guard Rail End Treatment, NCHRP 350 - 31" (TL-3 Flared) | EACH | 1 |
0059 | 706-01-00100 | Concrete Walk (4" Thick) | SQYD | 194.6 |
0060 | 706-02-00200 | Concrete Drive (6" Thick) | SQYD | 836 |
0061 | 706-03-00100 | Incidental Concrete Paving (4" Thick) | SQYD | 15.6 |
0062 | 706-03-00300 | Incidental Concrete Paving (6" Thick) | SQYD | 11,092.8 |
0063 | 706-03-00500 | Incidental Concrete Paving (8" Thick) | SQYD | 676.3 |
0064 | 706-03-00750 | Incidental Concrete Paving (11" Thick) | SQYD | 524.9 |
0065 | 707-03-00100 | Combination Concrete Curb and Gutter | LNFT | 16,246.9 |
0066 | 713-01-00100 | Temporary Signs and Barricades | LUMP | 1 |
0067 | 713-02-00100 | Temporary Pavement Markings (4" Width) | LNFT | 6,624 |
0068 | 713-02-00300 | Temporary Pavement Markings (8" Width) | LNFT | 86,089 |
0069 | 713-02-00500 | Temporary Pavement Markings (24" Width) | LNFT | 5,451 |
0070 | 713-03-01000 | Temporary Pavement Markings (Broken Line) (4" Width) (4' Length) | MILE | 32.979 |
0071 | 713-04-01000 | Temporary Pavement Markings (Solid Line) (4" Width) | MILE | 57.482 |
0072 | 713-05-00100 | Temporary Pavement Legends & Symbols (Arrow) | EACH | 164 |
0073 | 713-05-00200 | Temporary Pavement Legends & Symbols (Double Arrow) | EACH | 100 |
0074 | 713-06-00100 | Temporary Reflectorized Raised Pavement Markers | EACH | 9,086 |
0075 | 713-11-00100 | Portable Changeable Message Signs | EACH | 4 |
0076 | 722-02-00100 | Project Site Laboratory (Equipped) | EACH | 1 |
0077 | 724-02-00100 | Rumble Strips (Shoulder/Edge) | MILE | 8.36 |
0078 | 726-01-00100 | Bedding Material | CUYD | 791.7 |
0079 | 727-01-00100 | Mobilization | LUMP | 1 |
0080 | 729-01-00100 | Sign (Type A) | SQFT | 280 |
0081 | 729-01-00102 | Sign (Type A)(Furnish and Install) | SQFT | 3,203.9 |
0082 | 729-16-00200 | Object Marker Assembly (Type 2) | EACH | 213 |
0083 | 729-16-00300 | Object Marker Assembly (Type 3) | EACH | 8 |
0084 | 729-22-00100 | Square Tubing Post with 2-1/4" Anchor | EACH | 184 |
0085 | 731-01-00100 | Nonreflectorized Raised Pavement Markers | EACH | 449 |
0086 | 731-02-00100 | Reflectorized Raised Pavement Markers | EACH | 5,448 |
0087 | 732-01-02040 | Plastic Pavement Striping (8" Width) (Thermoplastic 125 mil) | LNFT | 21,249 |
0088 | 732-01-02080 | Plastic Pavement Striping (24" Width) (Thermoplastic 125 mil) | LNFT | 2,726 |
0089 | 732-02-02000 | Plastic Pavement Striping (Solid Line) (4" Width) (Thermoplastic 90 mil) | MILE | 22.506 |
0090 | 732-03-02000 | Plastic Pavement Striping (Broken Line) (4" Width) (Thermoplastic 90 mil) | MILE | 11.56 |
0091 | 732-03-02010 | Plastic Pavement Striping (Dotted Line)(4" W)(2' L)(Thermo 90 mil) | MILE | 0.627 |
0092 | 732-03-02030 | Plastic Pavement Striping (Dotted Line)(8" W)(2' L)(Thermo 90 mil) | MILE | 4.128 |
0093 | 732-04-00001 | Plastic Pavement Legends and Symbols (Message) NO | EACH | 2 |
0094 | 732-04-00001 | Plastic Pavement Legends and Symbols (Message) TRUCKS | EACH | 2 |
0095 | 732-04-01040 | Plastic Pavement Legends and Symbols (Arrow - Double) | EACH | 50 |
0096 | 732-04-01080 | Plastic Pavement Legends and Symbols (Arrow - Left Turn) | EACH | 32 |
0097 | 732-04-01100 | Plastic Pavement Legends and Symbols (Arrow - Right Turn) | EACH | 33 |
0098 | 732-04-01120 | Plastic Pavement Legends and Symbols (Arrow - Merge) | EACH | 2 |
0099 | 732-04-01121 | Plastic Pavement Legends and Symbols (U-Turn) | EACH | 20 |
0100 | 732-04-15020 | Plastic Pavement Legends and Symbols (ONLY) | EACH | 29 |
0101 | 732-04-16000 | Plastic Pavement Legends and Symbols (Pedestrian Crossing) | EACH | 8 |
0102 | 732-05-00100 | Removal of Existing Markings | MILE | 10.539 |
0103 | 735-01-00100 | Mailboxes | EACH | 88 |
0104 | 735-02-00100 | Mailbox Supports (Single) | EACH | 74 |
0105 | 735-03-00100 | Mailbox Supports (Double) | EACH | 7 |
0106 | 736-01-00100 | Trenching and Backfilling | LNFT | 1,340 |
0107 | 736-03-00100 | Jacking or Boring | LNFT | 1,565 |
0108 | 736-04-00001 | Signal Pole (Pedestal Pole) | EACH | 1 |
0109 | 736-04-10250 | Signal Pole (Single Mast Arm, 25ft) | EACH | 2 |
0110 | 736-04-10300 | Signal Pole (Single Mast Arm, 30ft) | EACH | 1 |
0111 | 736-04-10350 | Signal Pole (Single Mast Arm, 35ft) | EACH | 3 |
0112 | 736-04-10550 | Signal Pole (Single Mast Arm, 55ft) | EACH | 1 |
0113 | 736-04-10600 | Signal Pole (Single Mast Arm, 60ft) | EACH | 1 |
0114 | 736-04-10650 | Signal Pole (Single Mast Arm, 65ft) | EACH | 1 |
0115 | 736-04-23025 | Signal Pole (Dual Mast Arm, 30ft-Arm 1, 25ft-Arm 2) | EACH | 1 |
0116 | 736-04-24030 | Signal Pole (Dual Mast Arm, 40ft-Arm 1, 30ft-Arm 2) | EACH | 3 |
0117 | 736-04-24530 | Signal Pole (Dual Mast Arm, 45ft-Arm 1, 30ft-Arm 2) | EACH | 1 |
0118 | 736-05-10005 | Signal Heads (1 Section, 12 inch Led Lens, Y) | EACH | 2 |
0119 | 736-05-30000 | Signal Heads (3 Section, 12 inch Led Lens, R, Y, G) | EACH | 21 |
0120 | 736-05-31001 | Signal Heads (3 Sec, 12 inch Led Lens, LT. R, LT. Y, LT. G) | EACH | 17 |
0121 | 736-05-35001 | Signal Heads (3 Sec, 12 inch Led Lens, RT. R, RT. Y, RT. G) | EACH | 10 |
0122 | 736-06-00100 | Signal Service | EACH | 5 |
0123 | 736-06-00500 | Signal Service Pedestal Disconnect | EACH | 5 |
0124 | 736-08-00102 | Signal Controller (980 ATC, Type 2)(Furnish & Install) | EACH | 5 |
0125 | 736-10-00300 | Underground Junction Box (Type F) | EACH | 19 |
0126 | 736-10-00400 | Underground Junction Box (Type G) | EACH | 5 |
0127 | 736-11-00200 | Conduit (2" HDPE, Schedule 80) | LNFT | 1,285 |
0128 | 736-11-00300 | Conduit (3" HDPE, Schedule 80) | LNFT | 1,840 |
0129 | 736-12-03006 | Conductor (3c, 6 gauge / #6 awg) | LNFT | 575 |
0130 | 736-12-04012 | Conductor (4c, #12 awg) | LNFT | 97 |
0131 | 736-12-06014 | Conductor (6c, #14 awg) | LNFT | 2,612 |
0132 | 736-12-10014 | Conductor (10c, #14 awg) | LNFT | 5,533 |
0133 | 736-15-02400 | Signal Support (Foundation, 24 inch Minimum Diameter) | EACH | 1 |
0134 | 736-15-03600 | Signal Support (Foundation, 36 inch Minimum Diameter) | EACH | 11 |
0135 | 736-15-04200 | Signal Support (Foundation, 42 inch Minimum Diameter) | EACH | 2 |
0136 | 736-15-04800 | Signal Support (Foundation, 48 inch Minimum Diameter) | EACH | 1 |
0137 | 739-01-00100 | Hydro-Seeding | ACRE | 17.67 |
0138 | 740-01-00100 | Construction Layout | LUMP | 1 |
0139 | 822-13-00100 | Removal and Disposal of Light Pole Foundation CONCRETE FOUNDATION AND APRON | EACH | 19 |
0140 | NS-500-00340 | Saw Cutting Asphalt Concrete Pavement | INLF | 424,922 |
0141 | NS-500-00360 | Saw Cutting Asphalt Concrete Pavement Over Portland Cement Concrete Composite Pavement | INLF | 1,776 |
0142 | NS-600-00220 | Saw Cutting Portland Cement Concrete Pavement | INLF | 10,680 |
0143 | NS-700-00840 | Impact Attenuator (Reusable, Test Level 3) | EACH | 1 |
0144 | NS-729-00031 | Breakaway Square Tubing Sign Support (Surface Mount) | EACH | 44 |
0145 | NS-736-00001 | GPS | EACH | 5 |
0146 | NS-736-00020 | Wireless Magnetometer Vehicle Detection System (Cabinet Components) | EACH | 5 |
0147 | NS-736-00021 | Wireless Magnetometer Vehicle Detection System (Antennas) | EACH | 5 |
0148 | NS-736-00022 | Wireless Magnetometer Vehicle Detection System (Magnetometers) | EACH | 80 |
0149 | NS-736-00130 | TS-2 Traffic Signal Cabinet (Ground Mounted) | EACH | 5 |
0150 | NS-MSC-00080 | Detectable Warning System Retrofit for Curb Ramps | EACH | 16 |