Line Number | Item | Description | Unit | Quantity |
0001 | 202-02-00010 | Removal of Shed | EACH | 1 |
0002 | 202-02-00050 | Removal of Debris (Bridge Substructure) | LUMP | 1 |
0003 | 202-02-00050 | Removal of Debris (Bridge Superstructure) | LUMP | 1 |
0004 | 202-02-04560 | Removal of Bridge Joint (Seals Only) | LNFT | 2,180 |
0005 | 202-08-00100 | Removal of Debris (Bird Maintenance) | LUMP | 1 |
0006 | 713-01-00100 | Temporary Signs and Barricades | LUMP | 1 |
0007 | 713-04-01020 | Temporary Pavement Markings (Solid Line) (4"Width) (Type 1 Removable) | MILE | 1.926 |
0008 | 713-06-00100 | Temporary Reflectorized Raised Pavement Markers | EACH | 1,260 |
0009 | 713-07-00100 | Temporary Precast Concrete Barrier (Contractor Furnished) | EACH | 388 |
0010 | 713-10-00100 | Temporary Precast Concrete Barrier Movement | EACH | 388 |
0011 | 727-01-00100 | Mobilization | LUMP | 1 |
0012 | 731-02-00100 | Reflectorized Raised Pavement Markers | EACH | 885 |
0013 | 732-02-02000 | Plastic Pavement Striping (Solid Line) (4" Width) (Thermoplastic 90 mil) | MILE | 2.334 |
0014 | 732-03-02000 | Plastic Pavement Striping (Broken Line) (4" Width) (Thermoplastic 90 mil) | MILE | 1.273 |
0015 | 732-05-00100 | Removal of Existing Markings | MILE | 5.678 |
0016 | 804-17-00100 | Construction Site Survey | LUMP | 1 |
0017 | 805-18-00200 | Concrete Finish (Class 3 Special Finish) | SQFT | 146,656 |
0018 | 807-01-00800 | Structural Metalwork (M270, GR 36) | LUMP | 1 |
0019 | 810-04-00100 | Hand Railing Steel | LNFT | 5,920 |
0020 | 811-01-00100 | Cleaning and Painting (Hand Railing) | LUMP | 1 |
0021 | 811-01-00100 | Cleaning and Painting Approach Spans | LUMP | 1 |
0022 | 811-01-00100 | Cleaning and Painting Deck truss Spans | LUMP | 1 |
0023 | 811-01-00100 | Cleaning and Painting Guardrail | LUMP | 1 |
0024 | 811-01-00100 | Cleaning and Painting Main Truss Spans | LUMP | 1 |
0025 | 815-03-00200 | Joint Seal (Preformed Silicone) | LNFT | 2,180 |
0026 | 830-01-00100 | Bridge Superstructure Repair Concrete Curb at Shed | EACH | 1 |
0027 | 830-01-00100 | Bridge Superstructure Repair Deck Truss Bracing | EACH | 10 |
0028 | 830-01-00100 | Bridge Superstructure Repair Heat Straightening | EACH | 1 |
0029 | 830-11-00100 | Bolt-Rivet Replacement (Structural Steel) | EACH | 1,264 |
0030 | NS-700-00800 | Impact Attenuator (Construction Zone)(Test Level 2) | EACH | 2 |
0031 | NS-700-00820 | Impact Attenuator Relocation (Construction Zone) | EACH | 2 |
0032 | NS-830-00900 | Epoxy-Urethane Overlay | SQFT | 115,113 |
0033 | NS-830-01200 | Carbon Fiber Reinforced Polymer Repairs Substructure - Approach Spans | SQFT | 2,872 |
0034 | NS-830-01200 | Carbon Fiber Reinforced Polymer Repairs Superstructure - Approach Spans | SQFT | 15,456 |
0035 | NS-830-01200 | Carbon Fiber Reinforced Polymer Repairs Superstructure - Deck Truss Spans | SQFT | 7,751 |
0036 | NS-830-01200 | Carbon Fiber Reinforced Polymer Repairs Superstructure - Main Truss Spans | SQFT | 11,565 |
0037 | NS-830-01200 | Carbon Fiber Reinforced Polymer Repairs Superstructure - Steel Span 9 | SQFT | 1,040 |
0038 | NS-830-01800 | Methyl Methacrylate Concrete Sealer | SQFT | 40,759 |