Line Number | Item | Description | Unit | Quantity |
0001 | 202-02-00030 | Removal of Removal of Bridge Rail | LNFT | 80 |
0002 | 202-02-04505 | Removal of Bridge Deck (Full Depth) Full depth deck removal over damaged girder 1 on steel SB structure | SQFT | 793.33 |
0003 | 202-02-04540 | Removal of Bridge Component Removal of Steel Bridge Girder 1 | EACH | 1 |
0004 | 713-01-00100 | Temporary Signs and Barricades | LUMP | 1 |
0005 | 713-04-01020 | Temporary Pavement Markings (Solid Line) (4"Width) (Type 1 Removable) | MILE | 1.497 |
0006 | 713-06-00100 | Temporary Reflectorized Raised Pavement Markers | EACH | 527 |
0007 | 713-08-00100 | Temporary Precast Concrete Barrier (Department Furnished) | EACH | 30 |
0008 | 727-01-00100 | Mobilization | LUMP | 1 |
0009 | 729-06-00100 | Sign (Overhead Mounted) | SQFT | 224 |
0010 | 729-13-00100 | Mounting (Bridge Fascia Mounted) | EACH | 1 |
0011 | 731-02-00100 | Reflectorized Raised Pavement Markers | EACH | 166 |
0012 | 731-03-00100 | Removal of Raised Pavement Markers | MILE | 1.729 |
0013 | 732-02-02000 | Plastic Pavement Striping (Solid Line) (4" Width) (Thermoplastic 90 mil) | MILE | 0.374 |
0014 | 732-03-02000 | Plastic Pavement Striping (Broken Line) (4" Width) (Thermoplastic 90 mil) | MILE | 0.469 |
0015 | 732-05-00100 | Removal of Existing Markings | MILE | 2.561 |
0016 | 740-01-00100 | Construction Layout | LUMP | 1 |
0017 | 805-01-00900 | Class A1 Concrete High Early Strength | CUYD | 22.04 |
0018 | 805-18-00100 | Concrete Finish (Class 2 Rubbed Finish) | SQFT | 392.17 |
0019 | 805-18-00200 | Concrete Finish (Class 3 Special Finish) | SQFT | 817.34 |
0020 | 806-01-00100 | Deformed Reinforcing Steel | LB | 5,675 |
0021 | 807-01-00800 | Structural Metalwork G1, G2 studs, Stiffeners, Diaphragms | LUMP | 1 |
0022 | 811-01-00100 | Cleaning and Painting G1 and G4 on Steel SB structure need paint | LUMP | 1 |
0023 | 830-01-00100 | Bridge Superstructure Repair Haunch Grouting (Beam 2) | EACH | 1 |
0024 | 830-01-00100 | Bridge Superstructure Repair Haunch Grouting (Beam 4) | EACH | 1 |
0025 | 830-01-00100 | Bridge Superstructure Repair Heat Straightening | EACH | 1 |
0026 | 830-01-00100 | Bridge Superstructure Repair Prestressed Strand Splicing | EACH | 7 |
0027 | 830-02-00100 | Bridge Substructure Repair Bearing angles Girder 1 | EACH | 2 |
0028 | 830-07-00100 | Structural Concrete Patching | SQFT | 42 |
0029 | 830-10-00100 | Epoxy Injection | LNFT | 176 |
0030 | 830-11-00100 | Bolt-Rivet Replacement (Structural Steel) | EACH | 112 |
0031 | NS-700-00020 | Adjusting Guard Rail | LNFT | 80 |
0032 | NS-700-00810 | Impact Attenuator (Construction Zone)(Test Level 3) | EACH | 1 |
0033 | NS-713-00009 | Portable Changeable Message Sign (with communications) | EACH | 7 |
0034 | NS-830-01200 | Carbon Fiber Reinforced Polymer Repairs | SQFT | 128 |