Line Number | Item | Description | Unit | Quantity |
0001 | 201-01-00100 | Clearing and Grubbing | LUMP | 1 |
0002 | 203-05-00100 | Excavation and Embankment | LUMP | 1 |
0003 | 204-05-00100 | Temporary Sediment Check Dams (Hay) | EACH | 12 |
0004 | 204-06-00100 | Temporary Silt Fencing | LNFT | 1,400 |
0005 | 706-03-00300 | Incidental Concrete Paving (6" Thick) | SQYD | 20 |
0006 | 713-01-00100 | Temporary Signs and Barricades | LUMP | 1 |
0007 | 717-01-00100 | Seeding | LB | 3.77 |
0008 | 727-01-00100 | Mobilization | LUMP | 1 |
0009 | 740-01-00100 | Construction Layout | LUMP | 1 |
0010 | 803-01-00700 | Drilled Shaft (54" Diameter) | LNFT | 160 |
0011 | 803-08-00700 | Crosshole Sonic Log Test (54" Diameter) | EACH | 4 |
0012 | 822-01-00100 | Trenching and Backfilling | LNFT | 9,820 |
0013 | 822-02-00200 | Conduit w Conductors (PVC/HDPE) (1") (2#10 1#10 Bare Stranded Ground) (I) | LNFT | 300 |
0014 | 822-02-00200 | Conduit w Conductors (PVC/HDPE) (1") (2#6 1#6 Bare Stranded Ground) (E) | LNFT | 9,980 |
0015 | 822-02-00500 | Conduit w Conductors (PVC/HDPE) (2") (3#1/0) (B) | LNFT | 400 |
0016 | 822-02-01100 | Conduit w Conductors (Rigid Alum) (3/4") (2#10, 1#10 Green Insulated Ground) (G) | LNFT | 300 |
0017 | 822-02-03100 | Conduit w Conductors (Liq Tight Flexible Metal) (3/4") (2#10, 1#10 Green Insulated Ground) (H) | LNFT | 12 |
0018 | 822-02-04100 | Conduit w Conductors (Fiberglass) (3/4") (2#10 1#10 Bare Stranded Ground) (F) | LNFT | 110 |
0019 | 822-02-04200 | Conduit w Conductors (Fiberglass) (1") (2#6, 1#6 Bare Stranded Ground) (D) | LNFT | 30 |
0020 | 822-02-04500 | Conduit w Conductors (Fiberglass) (2") (2#1/0, 1#1/0 White Neutral, 1#2 Green Insulated Ground) (C) | LNFT | 30 |
0021 | 822-02-04500 | Conduit w Conductors (Fiberglass) (2") (3#1/0) (A) | LNFT | 20 |
0022 | 822-04-00200 | Jacked or Bored Casing (6" Dia) (PVC/HDPE) | LNFT | 860 |
0023 | 822-05-01700 | Light Pole (50') (Alum) (Single Arm) (Ground Mount, Breakaway) | EACH | 10 |
0024 | 822-05-01900 | Light Pole (50') (Alum) (Twin Arm) (Median ground mount, non-breakaway) | EACH | 13 |
0025 | 822-06-01000 | High Mast Pole (130') (6 Luminaire) | EACH | 2 |
0026 | 822-06-01100 | High Mast Pole (130') (8 Luminaire) | EACH | 2 |
0027 | 822-07-02800 | Luminaire (Highmast) (LED) (4K) | EACH | 28 |
0028 | 822-07-02800 | Luminaire (Lowmast) (LED) (4K) | EACH | 36 |
0029 | 822-07-02800 | Luminaire (Underpass) (LED) (4K) | EACH | 4 |
0030 | 822-08-00200 | Electrical Service Point (Structure) | EACH | 2 |
0031 | 822-11-00100 | Removal and Disposal of Electrical Equipment | LUMP | 1 |
0032 | 822-12-00100 | Removal and Storage of Light Pole (Ground Mount) (Ground Mount) (Lowmast; 35' Mounting Height) | EACH | 40 |
0033 | 822-12-00300 | Removal and Storage of Light Pole (Direct Buried) (Lowmast; 35' Mounting Height) | EACH | 22 |
0034 | 822-12-00300 | Removal and Storage of Light Pole (Direct Buried) (Lowmast; 60' Mounting Height) | EACH | 6 |
0035 | 822-13-00100 | Removal and Disposal of Light Pole Foundation (Lowmast) (35' Mounting Height) | EACH | 40 |
0036 | 822-14-00100 | Removal and Disposal of Luminaire | EACH | 97 |
0037 | 822-16-00200 | Underground Junction Box (11" x 18") (JB2) | EACH | 35 |
0038 | 822-16-00300 | Underground Junction Box (13" x 24") (JB3) | EACH | 20 |
0039 | 822-17-00400 | Structure Junction Box (Stainless Steel) (10" x 8" x 4") | EACH | 11 |
0040 | 822-19-00100 | Modular Breakaway Cable System | EACH | 10 |
0041 | 822-20-00100 | Disconnect (Service) (Fused) | EACH | 2 |
0042 | 822-20-00100 | Disconnect (Service) (Non-fused) | EACH | 2 |
0043 | 822-20-00200 | Disconnect (Underpass) (2P, 20A, 600V) | EACH | 1 |
0044 | 822-21-00100 | Duct Marker (Concrete) | EACH | 28 |
0045 | 822-22-00300 | Underground Marker Tape (6")(Detectable) | LNFT | 9,820 |