Line Number | Item | Description | Unit | Quantity |
0001 | 201-01-00100 | Clearing and Grubbing | LUMP | 1 |
0002 | 202-01-00100 | Removal of Structures and Obstructions | LUMP | 1 |
0003 | 202-02-00020 | Removal of Base Course | SQYD | 726 |
0004 | 202-02-04500 | Removal of Bridge (Steel Girder Span) | SQFT | 4,843 |
0005 | 202-02-04510 | Removal of Bridge Deck (Hydro Demolition) (I-110) | SFIN | 6,646 |
0006 | 202-02-04520 | Removal of Bridge Component (Cap) | LNFT | 29 |
0007 | 202-02-04520 | Removal of Bridge Component (Column) | LNFT | 25 |
0008 | 202-02-04520 | Removal of Bridge Component (Pile) | LNFT | 9 |
0009 | 202-02-04540 | Removal of Bridge Component (Footing) | EACH | 1 |
0010 | 202-02-04540 | Removal of Bridge Component (Riser) | EACH | 7 |
0011 | 202-02-06080 | Removal of Concrete Combination Curb and Gutter | LNFT | 63.3 |
0012 | 202-02-06100 | Removal of Concrete Walks and Drives | SQYD | 421 |
0013 | 202-02-26300 | Removal of Median / Island | SQYD | 262 |
0014 | 202-02-32500 | Removal of Portland Cement Concrete Pavement | SQYD | 737 |
0015 | 202-02-38220 | Removal of Sign Supports | EACH | 1 |
0016 | 202-02-38300 | Removal of Sign and U-Channel Post | EACH | 11 |
0017 | 202-02-38320 | Removal of Sign Supports (Overhead) | EACH | 1 |
0018 | 202-02-38360 | Removal of Sign Faces | EACH | 11 |
0019 | 203-01-00100 | General Excavation | CUYD | 212 |
0020 | 203-03-00100 | Embankment | CUYD | 587 |
0021 | 203-05-00100 | Excavation and Embankment | LUMP | 1 |
0022 | 204-02-00100 | Temporary Hay Bales | EACH | 15 |
0023 | 204-06-00100 | Temporary Silt Fencing | LNFT | 2,056 |
0024 | 302-02-08000 | Class II Base Course (8" Thick) . | SQYD | 552.8 |
0025 | 304-01-00100 | Lime | TON | 7.83 |
0026 | 304-05-00100 | Lime Treatment (Type E) | SQYD | 553 |
0027 | 601-01-00300 | Portland Cement Concrete Pavement (9" Thick) | SQYD | 155.8 |
0028 | 601-02-00900 | Portland Cement Concrete Pavement (9" Thick) (Crossovers & Turnouts) | SQYD | 261.4 |
0029 | 601-04-00100 | Portland Cement Concrete Pavement Coring | EACH | 1 |
0030 | 701-03-01000 | Storm Drain Pipe (15" RCP/PP) | LNFT | 160 |
0031 | 702-03-00100 | Catch Basins (CB-01) | EACH | 3 |
0032 | 702-03-00500 | Catch Basins (CB-06) | EACH | 1 |
0033 | 702-04-00100 | Adjusting Manholes | EACH | 1 |
0034 | 706-01-00100 | Concrete Walk (4" Thick) | SQYD | 257.5 |
0035 | 706-02-00200 | Concrete Drive (6" Thick) | SQYD | 113 |
0036 | 706-03-00100 | Incidental Concrete Paving (4" Thick) | SQYD | 45.9 |
0037 | 706-03-00300 | Incidental Concrete Paving (6" Thick) | SQYD | 125.7 |
0038 | 706-04-00100 | Handicapped Curb Ramps | EACH | 10 |
0039 | 707-01-00200 | Concrete Curb (Barrier) | LNFT | 402.2 |
0040 | 707-03-00100 | Combination Concrete Curb and Gutter | LNFT | 410.8 |
0041 | 712-01-00100 | Concrete Cast-in-Place Revetment (4" Thick) | SQYD | 23 |
0042 | 713-01-00100 | Temporary Signs and Barricades | LUMP | 1 |
0043 | 713-04-01020 | Temporary Pavement Markings (Solid Line) (4"Width) (Type 1 Removable) | MILE | 3.846 |
0044 | 713-07-00100 | Temporary Precast Concrete Barrier (Contractor Furnished) | EACH | 53 |
0045 | 713-10-00100 | Temporary Precast Concrete Barrier Movement | EACH | 52 |
0046 | 713-11-00100 | Portable Changeable Message Signs | EACH | 2 |
0047 | 714-01-00500 | Slab Sodding (Common Bermuda) | SQYD | 2,700 |
0048 | 715-01-00100 | Topsoil | CUYD | 502 |
0049 | 718-01-00100 | Fertilizer | LB | 300 |
0050 | 718-02-00100 | Agricultural Lime | TON | 1 |
0051 | 722-01-00100 | Project Site Laboratory | EACH | 1 |
0052 | 726-01-00100 | Bedding Material | CUYD | 16.6 |
0053 | 727-01-00100 | Mobilization | LUMP | 1 |
0054 | 729-01-00102 | Sign (Type A)(Furnish and Install) | SQFT | 403.5 |
0055 | 729-04-00102 | Sign (Type D)(Furnish and Install) | SQFT | 95.5 |
0056 | 729-05-00102 | Sign (Type E)(Furnish and Install) | SQFT | 120 |
0057 | 729-06-00102 | Sign (Overhead Mounted)(Furnish and Install) | SQFT | 617.5 |
0058 | 729-08-00200 | Mounting (3 1/2" Size Post) | EACH | 4 |
0059 | 729-08-00300 | Mounting (5" Size Post) | EACH | 2 |
0060 | 729-08-00310 | Mounting (5" Size Post)(Structure Mount) | EACH | 5 |
0061 | 729-08-00600 | Mounting (W6 x 12 Size Post) | EACH | 4 |
0062 | 729-08-00610 | Mounting (W6 x 12 Size Post)(Structure Mount) | EACH | 1 |
0063 | 729-12-00100 | Mounting (Overhead Cantilever) (Structure Mounted) | EACH | 1 |
0064 | 729-13-00100 | Mounting (Bridge Fascia Mounted) | EACH | 1 |
0065 | 729-19-00300 | Dead End Road Installations (Type C) T Intersection | EACH | 1 |
0066 | 729-22-00200 | Square Tubing Post with 2-1/4" Omni-Directional Anchor | EACH | 15 |
0067 | 731-02-00100 | Reflectorized Raised Pavement Markers | EACH | 1,140 |
0068 | 732-01-02080 | Plastic Pavement Striping (24" Width) (Thermoplastic 125 mil) | LNFT | 46 |
0069 | 732-02-02000 | Plastic Pavement Striping (Solid Line) (4" Width) (Thermoplastic 90 mil) | MILE | 1.847 |
0070 | 732-02-02040 | Plastic Pavement Striping (Solid Line) (8" Width) (Thermoplastic 90 mil) | MILE | 0.373 |
0071 | 732-02-02080 | Plastic Pavement Striping (Solid Line) (24" Width) (Thermoplastic 90 mil) | MILE | 0.086 |
0072 | 732-03-02000 | Plastic Pavement Striping (Broken Line) (4" Width) (Thermoplastic 90 mil) | MILE | 0.057 |
0073 | 732-03-02001 | Plastic Pavement Striping (Broken Line) (4" Width) (Thermo 90 mil)(Blk Cont) | MILE | 0.775 |
0074 | 732-03-02040 | Plastic Pavement Striping (Dotted Line)(8" W)(3' L)(Thermo 90 mil) | MILE | 0.386 |
0075 | 732-04-01080 | Plastic Pavement Legends and Symbols (Arrow - Left Turn) | EACH | 4 |
0076 | 732-04-05040 | Plastic Pavement Legends and Symbols (EXIT ONLY) | EACH | 2 |
0077 | 732-05-00100 | Removal of Existing Markings | MILE | 0.709 |
0078 | 739-01-00100 | Hydro-Seeding | ACRE | 0.9 |
0079 | 740-01-00100 | Construction Layout | LUMP | 1 |
0080 | 802-01-00100 | Structural Excavation (Bents) | CUYD | 46 |
0081 | 803-01-00200 | Drilled Shaft (24" Diameter) | LNFT | 564 |
0082 | 803-01-00400 | Drilled Shaft (36" Diameter) | LNFT | 110 |
0083 | 803-01-00600 | Drilled Shaft (48" Diameter) | LNFT | 200 |
0084 | 803-01-01300 | Drilled Shaft (96" Diameter) | LNFT | 889 |
0085 | 803-02-01300 | Test Shaft (96" Diameter) | LNFT | 105 |
0086 | 803-07-01300 | Bi-Directional Load Cell Test (96" Diameter) | EACH | 1 |
0090 | 803-08-01300 | Crosshole Sonic Log Test (96" Diameter) | EACH | 10 |
0091 | 803-10-00200 | Permanent Casing (24" Diameter) | LNFT | 240 |
0092 | 803-10-01300 | Permanent Casing (96" Diameter) | LNFT | 180 |
0093 | 804-18-00100 | Vibration Monitoring | DAY | 1 |
0094 | 805-01-00200 | Class A1 Concrete (Deck) | CUYD | 552.08 |
0095 | 805-01-00300 | Class A1 Concrete (Bent Cap) | CUYD | 2.33 |
0096 | 805-04-00100 | Class MASS(A1) Concrete (Bent Cap) | CUYD | 256.91 |
0097 | 805-04-00200 | Class MASS(A1) Concrete (Column) | CUYD | 108.7 |
0098 | 805-04-00300 | Class MASS(A1) Concrete (Footing) | CUYD | 32.73 |
0099 | 805-18-00100 | Concrete Finish (Class 2 Rubbed Finish) | SQFT | 8,753 |
0100 | 805-18-00200 | Concrete Finish (Class 3 Special Finish) | SQFT | 24,384 |
0101 | 806-01-00100 | Deformed Reinforcing Steel | LB | 300,396 |
0102 | 807-01-00200 | Structural Metalwork (Grade 50) | LUMP | 1 |
0103 | 807-02-00100 | Structural Metalwork (Anchor Bolts) | LUMP | 1 |
0104 | 810-01-00100 | Concrete Bridge Railing (Standard) | LNFT | 1,055 |
0105 | 810-01-00100 | Concrete Bridge Railing (Standard) (TL-5) | LNFT | 171 |
0106 | 810-01-00400 | Concrete Bridge Railing (Transition) | LNFT | 100 |
0107 | 810-05-00400 | Concrete Roadway Barrier (Transition) | LNFT | 80 |
0108 | 811-01-00100 | Cleaning and Painting (Connections) | LUMP | 1 |
0109 | 813-01-00100 | Concrete Approach Slabs (Cast-in-Place) | SQFT | 1,050 |
0110 | 814-02-00100 | Elastomeric Bearing Pads (Reinforced) | SFIN | 305 |
0111 | 815-01-00300 | Unsealed Expansion Joint (Sliding Plate) | LNFT | 148 |
0112 | 815-02-00100 | Sealed Expansion Joint (End Dams and Preformed Neoprene Seal) | LNFT | 180 |
0113 | 816-01-00100 | Bridge Deck Drainage System (Collection) | LUMP | 1 |
0114 | 822-01-00100 | Trenching and Backfilling | LNFT | 80 |
0115 | 822-02-00500 | Conduit w Conductors (PVC/HDPE) (2") (EMPTY) | LNFT | 240 |
0116 | 822-02-01100 | Conduit w Conductors (Rigid Alum) (3/4") (Conduit C; 2#10, 1#10 Green Insulated Ground) | LNFT | 300 |
0117 | 822-02-01400 | Conduit w Conductors (Rigid Alum) (1-1/2") (Conduit B; 2#6, 1#6 Green Insulated Ground) | LNFT | 745 |
0118 | 822-02-03100 | Conduit w Conductors (Liq Tight Flexible Metal) (3/4") (Conduit D; 2#10, 1#10 Green Insulated Ground) | LNFT | 18 |
0119 | 822-02-03400 | Conduit w Conductors (Liq Tight Flexible Metal) (1-1/2") (Conduit A; 2#6, 1#6 Green Insulated Ground) | LNFT | 18 |
0120 | 822-05-02100 | Light Pole (35') (Alum) (Single Arm) | EACH | 6 |
0121 | 822-07-00700 | Luminaire (100 Watt) (High Pressure Sodium) (Lowmast) | EACH | 6 |
0122 | 822-07-00700 | Luminaire (100 Watt) (High Pressure Sodium) (Underpass) | EACH | 6 |
0123 | 822-09-00100 | Electrical System (IP ADDRESSABLE PDU) | LUMP | 1 |
0124 | 822-11-00100 | Removal and Disposal of Electrical Equipment | LUMP | 1 |
0125 | 822-14-00100 | Removal and Disposal of Luminaire | EACH | 2 |
0126 | 822-17-00400 | Structure Junction Box (Stainless Steel) (10" x 4" x 4") | EACH | 11 |
0127 | 822-20-00200 | Disconnect (Underpass) | EACH | 2 |
0128 | 822-22-00300 | Underground Marker Tape (6")(Detectable) | LNFT | 80 |
0129 | 830-07-00100 | Structural Concrete Patching | SQFT | 24 |
0130 | NS-600-00220 | Saw Cutting Portland Cement Concrete Pavement | INLF | 5,899 |
0131 | NS-700-00810 | Impact Attenuator (Construction Zone)(Test Level 3) | EACH | 1 |
0132 | NS-700-00840 | Impact Attenuator (Test Level 3) (Kinetic) | EACH | 1 |
0133 | NS-729-00010 | Bridge-Mounted Sign Struct Found Retrofit (Steel) Sign Cant | EACH | 1 |
0134 | NS-729-00031 | Breakaway Square Tubing Sign Support - Hard Concrete | EACH | 3 |
0135 | NS-ENH-03000 | Catch Basin Top ADA Grate | EACH | 1 |
0136 | NS-ITS-01241 | CCTV C/Assembly, Install with PTZ, Digital | EACH | 2 |
0137 | NS-ITS-03501 | CCTV Camera Site, Remove | EACH | 1 |
0138 | NS-ITS-04290 | Fiber Optic Patch Cord, SM, 2 Strand, Furnish & Install | EACH | 2 |
0139 | NS-ITS-06020 | Pullbox, In-ground, Furnish & Install - New | EACH | 1 |
0140 | NS-ITS-08101 | Pole, Foundation & Lowering Device, >= 100', Furnish & Install (110') | EACH | 1 |
0141 | NS-ITS-09100 | Local Ethernet Switch, Install | EACH | 1 |
0142 | NS-ITS-10220 | Power Surge Suppressor, Furnish & Install | EACH | 2 |
0143 | NS-ITS-10340 | Data Surge Suppressor, Furnish & Install | EACH | 4 |
0144 | NS-ITS-12020 | TMC Integration | LUMP | 1 |
0145 | NS-ITS-13080 | Maintenance Procedures Manuals | LUMP | 1 |
0146 | NS-ITS-13200 | As-Builts | LUMP | 1 |
0147 | NS-MSC-00120 | Drainage Structure PG-Drain | EACH | 1 |
0148 | 803-09-00210 | Non-Destructive Test (24” Diameter) (Thermal Integrity Profiling) | EACH | 6 |
0149 | 803-09-00410 | Non-Destructive Test (36” Diameter) (Thermal Integrity Profiling) | EACH | 2 |
0150 | 803-09-00610 | Non-Destructive Test (48” Diameter) (Thermal Integrity Profiling) | EACH | 2 |
0151 | 803-09-01310 | Non-Destructive Test (96” Diameter) (Thermal Integrity Profiling) | EACH | 10 |