Line Number | Item | Description | Unit | Quantity |
| 0001 | 201-01-00100 | Clearing and Grubbing | LUMP | 1 |
| 0002 | 202-01-00100 | Removal of Structures and Obstructions | LUMP | 1 |
| 0003 | 202-02-02000 | Removal of Asphalt Drives | SQYD | 459 |
| 0004 | 202-02-06100 | Removal of Concrete Walks and Drives | SQYD | 327 |
| 0005 | 202-02-14500 | Removal of Guard Rail | LNFT | 2,400 |
| 0006 | 202-02-38240 | Removal of Signs and Supports | EACH | 48 |
| 0007 | 202-03-38000 | Relocation of Sign | EACH | 1 |
| 0008 | 203-01-00100 | General Excavation | CUYD | 11,720 |
| 0009 | 203-03-00100 | Embankment | CUYD | 11,337 |
| 0010 | 204-05-00100 | Temporary Sediment Check Dams (Hay) | EACH | 319 |
| 0011 | 204-05-00200 | Temporary Sediment Check Dams (Stone) | EACH | 10 |
| 0012 | 204-06-00100 | Temporary Silt Fencing | LNFT | 12,660 |
| 0013 | 302-02-12010 | Class II Base Course (12" Thick) (Soil Cement) | SQYD | 26,820 |
| 0014 | 304-01-00100 | Lime | TON | 380.2 |
| 0015 | 304-05-00100 | Lime Treatment (Type E) | SQYD | 26,817 |
| 0016 | 401-02-00100 | Aggregate Surface Course (Adjusted Vehicular Measurement) | CUYD | 4,859 |
| 0017 | 402-01-00101 | Traffic Maintenance Surfacing (Aggregate) (Vehicular Measurement) | CUYD | 50 |
| 0018 | 502-01-00100 | Asphalt Concrete | TON | 63,935.7 |
| 0019 | 502-01-00200 | Asphalt Concrete, Drives, Turnouts and Miscellaneous | TON | 5,915.9 |
| 0020 | 509-01-00100 | Milling Asphalt Pavement | SQYD | 260,789 |
| 0021 | 509-02-00100 | Contractor Retained Reclaimed Asphalt Pavement | CUYD | -21,736 |
| 0022 | 510-01-00001 | Pavement Patching (15" Minimum Thickness) | SQYD | 4,506 |
| 0023 | 511-01-00100 | Saw Cutting Asphalt Concrete Pavement | INLF | 313,355 |
| 0024 | 701-05-01042 | Side Drain Pipe (18" RCP/RPVCP/CPEPDW/CMP) | LNFT | 230 |
| 0025 | 701-05-01061 | Side Drain Pipe (24" RCP/RPVCP/CPEPDW/CMP) | LNFT | 104 |
| 0026 | 701-10-01060 | Reinforced Concrete Pipe (Extension) (24") | LNFT | 40 |
| 0027 | 701-10-01080 | Reinforced Concrete Pipe (Extension) (30") | LNFT | 36 |
| 0028 | 701-10-01100 | Reinforced Concrete Pipe (Extension) (36") | LNFT | 70 |
| 0029 | 701-10-01120 | Reinforced Concrete Pipe (Extension) (42") | LNFT | 14 |
| 0030 | 701-10-01140 | Reinforced Concrete Pipe (Extension) (48") | LNFT | 12 |
| 0031 | 701-15-00100 | Concrete Collar | EACH | 14 |
| 0032 | 701-17-00100 | Trench Excavation Safety Protection (Depth >5 feet) | LNFT | 36 |
| 0033 | 702-04-00200 | Adjusting Catch Basins | EACH | 1 |
| 0034 | 702-07-00100 | Cross Drain Safety End (Type 1) | EACH | 14 |
| 0035 | 702-07-00200 | Cross Drain Safety End (Type 2) | EACH | 1 |
| 0036 | 702-08-00100 | Side Drain Safety End (Type 1) | EACH | 13 |
| 0037 | 704-01-01020 | Guard Rail (Single Thrie Beam) (6'-3" post spacing) | LNFT | 802 |
| 0038 | 704-03-00200 | Blocked Out Guard Rail - 31", (6'-3" Post Spacing) | LNFT | 1,362.5 |
| 0039 | 704-07-00200 | Guard Rail Transitions (Double Thrie Beam) | LNFT | 500 |
| 0040 | 704-10-00205 | Guard Rail End Treatment, MASH, (TL-3 Tangent) | EACH | 20 |
| 0041 | 706-02-00200 | Concrete Drive (6" Thick) | SQYD | 213 |
| 0042 | 713-01-00100 | Temporary Signs and Barricades | LUMP | 1 |
| 0043 | 713-03-01000 | Temporary Pavement Markings (Broken Line) (4" Width) (4' Length) | MILE | 22.722 |
| 0044 | 713-04-01000 | Temporary Pavement Markings (Solid Line) (4" Width) | MILE | 125.008 |
| 0045 | 713-06-00100 | Temporary Reflectorized Raised Pavement Markers | EACH | 4,872 |
| 0046 | 716-01-00100 | Mulch (Vegetative) | TON | 21.357 |
| 0047 | 717-01-00100 | Seeding | LB | 366 |
| 0048 | 718-01-00100 | Fertilizer | LB | 12,200 |
| 0049 | 720-01-01000 | Erosion Control System (Slope Protection) (Type A) | SQYD | 8,536 |
| 0050 | 720-01-02000 | Erosion Control System, Flexible (Channel Liner) (Type C) | SQYD | 2,033 |
| 0051 | 720-01-02020 | Erosion Control System, Flexible (Channel Liner) (Type D) | SQYD | 1,262 |
| 0052 | 722-02-00100 | Project Site Laboratory (Equipped) | EACH | 1 |
| 0053 | 724-01-00100 | Rumble Strips (Centerline) | MILE | 5.982 |
| 0054 | 726-01-00100 | Bedding Material | CUYD | 56 |
| 0055 | 727-01-00100 | Mobilization | LUMP | 1 |
| 0056 | 729-01-00100 | Sign (Type A) | SQFT | 230.6 |
| 0057 | 729-01-00200 | Mounting of Sign (Type A) | EACH | 30 |
| 0058 | 729-16-00200 | Object Marker Assembly (Type 2) | EACH | 12 |
| 0059 | 729-16-00300 | Object Marker Assembly (Type 3) | EACH | 20 |
| 0060 | 729-22-00100 | Perforated Square Tubing Post with 2-1/4" Anchor | EACH | 24 |
| 0061 | 731-01-00100 | Nonreflectorized Raised Pavement Markers | EACH | 104 |
| 0062 | 731-02-00100 | Reflectorized Raised Pavement Markers | EACH | 5,406 |
| 0063 | 732-01-01040 | Plastic Pavement Striping (8" Width) (Thermoplastic 90 mil) | LNFT | 2,374 |
| 0064 | 732-01-02080 | Plastic Pavement Striping (24" Width) (Thermoplastic 125 mil) | LNFT | 285 |
| 0065 | 732-02-02000 | Plastic Pavement Striping (Solid Line) (4" Width) (Thermoplastic 90 mil) | MILE | 69.519 |
| 0066 | 732-03-02000 | Plastic Pavement Striping (Broken Line) (4" Width) (Thermoplastic 90 mil) | MILE | 14.19 |
| 0067 | 732-04-01120 | Plastic Pavement Legends and Symbols (Arrow - Merge) | EACH | 8 |
| 0068 | 732-05-00100 | Removal of Existing Markings | MILE | 0.117 |
| 0069 | 735-01-00100 | Mailboxes | EACH | 163 |
| 0070 | 735-02-00100 | Mailbox Supports (Single) | EACH | 91 |
| 0071 | 735-03-00100 | Mailbox Supports (Double) | EACH | 36 |
| 0072 | 740-01-00100 | Construction Layout | LUMP | 1 |
| 0073 | 741-20-01080 | Water Main (6" PVC) | LNFT | 840 |
| 0074 | 741-22-00300 | Tapping Sleeve and Valve (6") | EACH | 2 |
| 0075 | 805-01-01000 | Class A1 Concrete (Headwalls) 24 inch | CUYD | 3.8 |
| 0076 | 805-01-01000 | Class A1 Concrete (Headwalls) 48 inch | CUYD | 10.64 |
| 0077 | 805-16-00600 | Reinforced Concrete Box Culverts (Extension) (5' x 5') | LNFT | 30 |
| 0078 | 805-16-01200 | Reinforced Concrete Box Culverts (Extension) (6' x 6') | LNFT | 12 |
| 0079 | 805-16-01700 | Reinforced Concrete Box Culverts (Extension) (7' x 7') | LNFT | 42 |
| 0080 | 805-17-00100 | Reinforced Concrete Box Culvert Headwall (5x5) (1345.36 LBS STEEL AND 17.92 CUYD CONCRETE). | EACH | 1 |
| 0081 | 805-17-00100 | Reinforced Concrete Box Culvert Headwall (6x6)(1493.28 LBS STEEL AND 21.12 CUYD CONCRETE) | EACH | 1 |
| 0082 | 805-17-00100 | Reinforced Concrete Box Culvert Headwall (7x7)(2404.60 LBS STEEL AND 35.62 CUYD CONCRETE) | EACH | 1 |
| 0083 | 806-01-00100 | Deformed Reinforcing Steel | LB | 797 |
| 0084 | NS-744-00101 | Flexible Post Traffic Delineators | EACH | 12 |
| 0085 | TS-741-60009 | Water Main Pipeline Markers | EACH | 2 |
| 0086 | TS-741-60011 | Cut, Cap and Block Existing Water Main | EACH | 2 |