Line Number | Item | Description | Unit | Quantity |
| 0001 | 201-01-00100 | Clearing and Grubbing | LUMP | 1 |
| 0002 | 202-01-00100 | Removal of Structures and Obstructions | LUMP | 1 |
| 0003 | 202-02-02020 | Removal of Asphalt Pavement | SQYD | 2,816.2 |
| 0004 | 202-02-06060 | Removal of Concrete Catch Basin | EACH | 7 |
| 0005 | 202-02-06100 | Removal of Concrete Walks and Drives | SQYD | 118 |
| 0006 | 202-02-12000 | Removal of Fence | LNFT | 536 |
| 0007 | 202-02-40100 | Removal of Traffic Signal Equipment | LUMP | 1 |
| 0008 | 203-01-00100 | General Excavation | CUYD | 41,260 |
| 0009 | 203-03-00100 | Embankment | CUYD | 10,765 |
| 0010 | 203-04-00200 | Nonplastic Embankment (Sand) | CUYD | 26,998 |
| 0011 | 203-08-00100 | Geotextile Fabric | SQYD | 49,926 |
| 0012 | 204-02-00100 | Temporary Hay Bales | EACH | 644 |
| 0013 | 204-05-00100 | Temporary Sediment Check Dams (Hay) | EACH | 1 |
| 0014 | 204-06-00100 | Temporary Silt Fencing | LNFT | 12,205 |
| 0015 | 302-02-08070 | Class II Base Course (8" Thick) (Crushed Stone or Recycled Portland Cement Concrete) | SQYD | 39,173.8 |
| 0016 | 302-02-12070 | Class II Base Course (12" Thick) (Crushed Stone or Recycled Portland Cement Concrete) | SQYD | 2,275.5 |
| 0017 | 402-01-00101 | Traffic Maintenance Surfacing (Aggregate) (Vehicular Measurement) | CUYD | 469.4 |
| 0018 | 402-02-00101 | Traffic Maintenance Surfacing (Hard) | SQYD | 400 |
| 0019 | 502-01-00200 | Asphalt Concrete, Drives, Turnouts and Miscellaneous | TON | 5,595.7 |
| 0020 | 509-01-00100 | Milling Asphalt Pavement | SQYD | 4,102 |
| 0021 | 509-02-00100 | Contractor Retained Reclaimed Asphalt Pavement | CUYD | -228 |
| 0022 | 601-01-00500 | Portland Cement Concrete Pavement (10" Thick) | SQYD | 39,134.7 |
| 0023 | 601-05-00100 | Saw Cutting Portland Cement Concrete Pavement | INLF | 2,102 |
| 0024 | 701-03-01002 | Storm Drain Pipe (15" RCP/RPVCP) | LNFT | 465 |
| 0025 | 701-03-01022 | Storm Drain Pipe (18" RCP/RPVCP) | LNFT | 911 |
| 0026 | 701-03-01042 | Storm Drain Pipe (24" RCP/RPVCP) | LNFT | 2,156 |
| 0027 | 701-03-01062 | Storm Drain Pipe (30" RCP/RPVCP) | LNFT | 821 |
| 0028 | 701-03-01082 | Storm Drain Pipe (36" RCP/RPVCP) | LNFT | 1,267 |
| 0029 | 701-03-01102 | Storm Drain Pipe (48" RCP/RPVCP) | LNFT | 4,607 |
| 0030 | 701-04-01080 | Storm Drain Pipe Arch (36" Equiv. RCPA) | LNFT | 106 |
| 0031 | 701-04-01120 | Storm Drain Pipe Arch (48" Equiv. RCPA) | LNFT | 129 |
| 0032 | 702-02-00100 | Manholes (MH-06) | EACH | 11 |
| 0033 | 702-03-00100 | Catch Basins (CB-01) | EACH | 29 |
| 0034 | 702-03-00200 | Catch Basins (CB-02) | EACH | 2 |
| 0035 | 702-03-00500 | Catch Basins (CB-06) | EACH | 1 |
| 0036 | 702-03-00600 | Catch Basins (CB-07) | EACH | 45 |
| 0037 | 702-03-00700 | Catch Basins (CB-08) | EACH | 22 |
| 0038 | 702-04-00200 | Adjusting Catch Basins | EACH | 2 |
| 0039 | 706-02-00400 | Concrete Drive (10" Thick) | SQYD | 101.8 |
| 0040 | 706-03-00300 | Incidental Concrete Paving (6" Thick) | SQYD | 162.9 |
| 0041 | 707-01-00100 | Concrete Curb | LNFT | 22,246.7 |
| 0042 | 713-01-00100 | Temporary Signs and Barricades | LUMP | 1 |
| 0043 | 713-11-00100 | Portable Changeable Message Signs | EACH | 2 |
| 0044 | 722-01-00100 | Project Site Laboratory | EACH | 1 |
| 0045 | 726-01-00100 | Bedding Material | CUYD | 4,668.5 |
| 0046 | 727-01-00100 | Mobilization | LUMP | 1 |
| 0047 | 729-01-00100 | Sign (Type A) | SQFT | 165.35 |
| 0048 | 729-01-00200 | Mounting of Sign (Type A) | EACH | 23 |
| 0049 | 729-22-00200 | Perforated Square Tubing Post with 2-1/4" Omni-Directional Anchor | EACH | 14 |
| 0050 | 731-02-00100 | Reflectorized Raised Pavement Markers | EACH | 409 |
| 0051 | 732-01-02080 | Plastic Pavement Striping (24" Width) (Thermoplastic 125 mil) | LNFT | 58 |
| 0052 | 732-02-02000 | Plastic Pavement Striping (Solid Line) (4" Width) (Thermoplastic 90 mil) | MILE | 4.607 |
| 0053 | 732-02-02040 | Plastic Pavement Striping (Solid Line) (8" Width) (Thermoplastic 90 mil) | MILE | 0.102 |
| 0054 | 732-03-02000 | Plastic Pavement Striping (Broken Line) (4" Width) (Thermoplastic 90 mil) | MILE | 2.097 |
| 0055 | 732-03-02010 | Plastic Pavement Striping (Dotted Line)(4" W)(2' L)(Thermo 90 mil) | MILE | 0.042 |
| 0056 | 732-03-02030 | Plastic Pavement Striping (Dotted Line)(8" W)(2' L)(Thermo 90 mil) | MILE | 0.25 |
| 0057 | 732-04-01060 | Plastic Pavement Legends and Symbols (Arrow - Triple) | EACH | 2 |
| 0058 | 732-04-01080 | Plastic Pavement Legends and Symbols (Arrow - Left Turn) | EACH | 4 |
| 0059 | 732-04-01121 | Plastic Pavement Legends and Symbols (U-Turn) | EACH | 5 |
| 0060 | 732-04-15020 | Plastic Pavement Legends and Symbols (ONLY) | EACH | 9 |
| 0061 | 736-01-00100 | Trenching and Backfilling | LNFT | 805 |
| 0062 | 736-03-00100 | Jacking or Boring for Conduit | LNFT | 390 |
| 0063 | 736-04-10250 | Signal Pole (Single Mast Arm, 25ft) | EACH | 1 |
| 0064 | 736-04-10450 | Signal Pole (Single Mast Arm, 45ft) | EACH | 1 |
| 0065 | 736-04-10500 | Signal Pole (Single Mast Arm, 50ft) | EACH | 2 |
| 0066 | 736-05-10005 | Signal Heads (1 Section, 12 inch Led Lens, Y) | EACH | 4 |
| 0067 | 736-05-30000 | Signal Heads (3 Section, 12 inch Led Lens, R, Y, G) | EACH | 9 |
| 0068 | 736-05-41200 | Signal Heads (4 Section, 12 inch Led Lens, LT. R, LT. Y, FLT. Y, LT. G) | EACH | 4 |
| 0069 | 736-06-00100 | Signal Service | EACH | 2 |
| 0070 | 736-06-00500 | Signal Service Pedestal Disconnect | EACH | 1 |
| 0071 | 736-08-00102 | Signal Controller (980 ATC, Type 2)(Furnish & Install) | EACH | 1 |
| 0072 | 736-09-00100 | Loop Detector | LNFT | 950 |
| 0073 | 736-10-00200 | Underground Junction Box (Type E) | EACH | 6 |
| 0074 | 736-10-00300 | Underground Junction Box (Type F) | EACH | 4 |
| 0075 | 736-10-00400 | Underground Junction Box (Type G) | EACH | 1 |
| 0076 | 736-11-00200 | Conduit (2" HDPE, Schedule 80) | LNFT | 640 |
| 0077 | 736-11-00300 | Conduit (3" HDPE, Schedule 80) | LNFT | 535 |
| 0078 | 736-12-00000 | Conductor (2c, Loop Lead in, imsa 50-2, #14 awg, Twisted Pair) | LNFT | 1,235 |
| 0079 | 736-12-03006 | Conductor (3c, 6 gauge / #6 awg) | LNFT | 40 |
| 0080 | 736-12-06014 | Conductor (6c, #14 awg) | LNFT | 515 |
| 0081 | 736-12-10014 | Conductor (10c, #14 awg) | LNFT | 1,300 |
| 0082 | 736-15-02400 | Signal Support (Foundation, 24 inch Minimum Diameter) | EACH | 1 |
| 0083 | 736-15-03600 | Signal Support (Foundation, 36 inch Minimum Diameter) | EACH | 4 |
| 0084 | 736-24-00000 | Flashing Switch Assembly For Beacons | EACH | 1 |
| 0085 | 739-01-00100 | Hydro-Seeding | ACRE | 9.7 |
| 0086 | 740-01-00100 | Construction Layout | LUMP | 1 |
| 0087 | NS-500-00360 | Saw Cutting Asphalt Concrete Pavement Over Portland Cement Concrete Composite Pavement | INLF | 24,214 |
| 0088 | NS-719-00001 | Tree Protection Fencing | LUMP | 1 |
| 0089 | NS-736-00130 | TS-2 Traffic Signal Cabinet (Ground Mounted) | EACH | 1 |