Line Number | Item | Description | Unit | Quantity |
| 0001 | 202-01-00100 | Removal of Structures and Obstructions | LUMP | 1 |
| 0002 | 202-02-06100 | Removal of Concrete Walks and Drives | SQYD | 15 |
| 0003 | 202-02-38300 | Removal of Sign and U-Channel Post | EACH | 2 |
| 0004 | 202-03-38000 | Relocation of Sign | EACH | 2 |
| 0005 | 203-01-00100 | General Excavation | CUYD | 875 |
| 0006 | 203-03-00100 | Embankment | CUYD | 20 |
| 0007 | 204-02-00100 | Temporary Hay Bales | EACH | 80 |
| 0008 | 204-06-00100 | Temporary Silt Fencing | LNFT | 2,000 |
| 0009 | 302-02-06070 | Class II Base Course (6" Thick) (Crushed Stone or Recycled Portland Cement Concrete) | SQYD | 2,767.56 |
| 0010 | 502-01-00100 | Asphalt Concrete | TON | 702.53 |
| 0011 | 706-01-00200 | Concrete Walk (5" Thick) | SQYD | 50 |
| 0012 | 706-04-00110 | Curb Ramps Type 3 | SQYD | 72.9 |
| 0013 | 713-01-00100 | Temporary Signs and Barricades | LUMP | 1 |
| 0014 | 714-01-00100 | Slab Sodding (Bermuda Grass) | SQYD | 865 |
| 0015 | 723-01-00100 | Granular Material (Net Section) | CUYD | 20 |
| 0016 | 727-01-00100 | Mobilization | LUMP | 1 |
| 0017 | 728-01-00300 | Jacked or Bored Pipe (6") | LNFT | 72 |
| 0018 | 732-03-02000 | Plastic Pavement Striping (Broken Line) (4" Width) (Thermoplastic 90 mil) | MILE | 0.36 |
| 0019 | 739-01-00100 | Hydro-Seeding | ACRE | 0.3 |
| 0020 | 740-01-00100 | Construction Layout | LUMP | 1 |
| 0021 | 741-38-00100 | Removal of Fire Hydrant | EACH | 4 |
| 0022 | TS-728-00500 | Directional Boring (Type) | LNFT | 600 |
| 0023 | TS-741-00100 | Fire Hydrant Assembly | EACH | 4 |
| 0024 | TS-741-01090 | Water Main (6" PVC) (PVC/C-900 Pipe) | LNFT | 20 |
| 0025 | TS-804-00100 | Helical Light Pole Foundations (Type A) | EACH | 29 |
| 0026 | TS-804-00200 | Helical Light Pole Foundations - Concrete Cap | EACH | 29 |
| 0027 | TS-822-00940 | 2 kVA Resin Encapsulated 480:120/240V, 1P Transformer | EACH | 1 |
| 0028 | TS-822-00941 | Electrical Panel; 100A, 277/480V, 100 amp, 42 Circuits | EACH | 1 |
| 0029 | TS-822-09105 | Trenching and Backfilling | LNFT | 1,500 |
| 0030 | TS-822-09110 | Conduit w Conductors (PVC/HDPE) 1 1/4 PVC W/ 4#8, 1#8 GRD) | LNFT | 10,000 |
| 0031 | TS-822-09111 | Conduit w Conductors (Rigid Alum) 1-1/4” Conduit, 4#8, 1#8 GND | LNFT | 500 |
| 0032 | TS-822-09134 | Light Pole Dunwoody series, 14' tall, Aluminum, 5" diameter, black, and fluted | EACH | 29 |
| 0033 | TS-822-09156 | Luminaire (Roadway) (LED) 4000K | EACH | 29 |
| 0034 | TS-822-09160 | Electrical Service Point 100A, Meter Pan, NEMA 3R Enclosure | EACH | 1 |
| 0035 | TS-822-09160 | Electrical Service Point Ground Rod | EACH | 30 |
| 0036 | TS-822-09160 | Electrical Service Point Lighting Control System | EACH | 1 |
| 0037 | TS-822-09160 | Electrical Service Point pedestal | EACH | 1 |
| 0038 | TS-822-09178 | Underground Marker Tape 0’-3” width | LNFT | 2,100 |
| 0039 | TS-MSC-00300 | Bike Racks | EACH | 2 |