Line Number | Item | Description | Unit | Quantity |
| 0001 | 201-01-00100 | Clearing and Grubbing | LUMP | 1 |
| 0002 | 202-01-00100 | Removal of Structures and Obstructions | LUMP | 1 |
| 0003 | 202-02-02020 | Removal of Asphalt Pavement | SQYD | 132.3 |
| 0004 | 202-02-06060 | Removal of Concrete Catch Basin | EACH | 2 |
| 0005 | 202-02-06080 | Removal of Concrete Combination Curb and Gutter | LNFT | 60.2 |
| 0006 | 202-02-06100 | Removal of Concrete Walks and Drives | SQYD | 19 |
| 0007 | 202-02-06140 | Removal of Curbs (Concrete) | LNFT | 6 |
| 0008 | 202-02-12020 | Removal of Fence (Chain Link) | LNFT | 278 |
| 0009 | 202-02-32140 | Removal of Pipe (Storm Drain) 18" RCP | LNFT | 68 |
| 0010 | 203-01-00100 | General Excavation | CUYD | 6,957 |
| 0011 | 203-03-00100 | Embankment | CUYD | 687 |
| 0012 | 203-08-00100 | Geotextile Fabric | SQYD | 7,966 |
| 0013 | 204-06-00100 | Temporary Silt Fencing | LNFT | 3,280 |
| 0014 | 301-01-00100 | Class I Base Course | CUYD | 3,580.1 |
| 0015 | 302-02-06000 | Class II Base Course (6" Thick) | SQYD | 5,042.6 |
| 0016 | 502-01-00100 | Asphalt Concrete | TON | 3,245.2 |
| 0017 | 601-01-00100 | Portland Cement Concrete Pavement (8" Thick) | SQYD | 66.7 |
| 0018 | 701-04-01000 | Storm Drain Pipe Arch (15" Equiv. RCPA) | LNFT | 40 |
| 0019 | 701-04-01020 | Storm Drain Pipe Arch (18" Equiv. RCPA) | LNFT | 123 |
| 0020 | 701-10-01020 | Reinforced Concrete Pipe (Extension) (15") | LNFT | 16 |
| 0021 | 702-03-00100 | Catch Basins (CB-01) (Type C) | EACH | 5 |
| 0022 | 705-06-00300 | Chain Link Fence (6-Foot Height) | LNFT | 3,381 |
| 0023 | 706-01-00100 | Concrete Walk (4" Thick) | SQYD | 354.1 |
| 0024 | 706-02-00300 | Concrete Drive (8" Thick) | SQYD | 65.6 |
| 0025 | 706-03-00100 | Incidental Concrete Paving (4" Thick) | SQYD | 95.4 |
| 0026 | 706-03-00300 | Incidental Concrete Paving (6" Thick) | SQYD | 56 |
| 0027 | 713-01-00100 | Temporary Signs and Barricades | LUMP | 1 |
| 0028 | 714-01-00100 | Slab Sodding (Bermuda Grass) | SQYD | 2,843 |
| 0029 | 723-01-00100 | Granular Material (Net Section) 4" THICK | CUYD | 81 |
| 0030 | 723-01-00100 | Granular Material (Net Section) 6" THICK | CUYD | 11 |
| 0031 | 726-01-00100 | Bedding Material | CUYD | 18.2 |
| 0032 | 727-01-00100 | Mobilization | LUMP | 1 |
| 0033 | 729-19-00400 | Dead End Road Installations (Type D) | EACH | 2 |
| 0034 | 732-01-01000 | Plastic Pavement Striping (4" Width) (Thermoplastic 90 mil) | LNFT | 288 |
| 0035 | 732-01-02080 | Plastic Pavement Striping (24" Width) (Thermoplastic 125 mil) | LNFT | 82 |
| 0036 | 732-03-02000 | Plastic Pavement Striping (Broken Line) (4" Width) (Thermoplastic 90 mil) | MILE | 0.605 |
| 0037 | 732-04-08000 | Plastic Pavement Legends and Symbols (Handicap Markings) (4" Width - Blue) | LNFT | 90 |
| 0038 | 732-04-08020 | Plastic Pavement Legends and Symbols (Handicap Markings) (6" Width - Blue) | LNFT | 65 |
| 0039 | 732-04-08040 | Plastic Pavement Legends and Symbols (Handicap Parking) | EACH | 2 |
| 0040 | 739-01-00100 | Hydro-Seeding | ACRE | 5.2 |
| 0041 | 740-01-00100 | Construction Layout | LUMP | 1 |
| 0042 | 802-01-00100 | Structural Excavation (Bents) | CUYD | 8 |
| 0043 | 804-02-00200 | Treated Timber Piles (Coastal Treatment) (Class B) | LNFT | 960 |
| 0044 | 804-09-01200 | Static Load Test (Treated Timber Piles (Coastal Treatment)) | EACH | 1 |
| 0045 | 804-14-00100 | Dynamic Monitoring Assistance | EACH | 2 |
| 0046 | 804-15-00100 | Dynamic Monitoring Instrumentation | LUMP | 1 |
| 0047 | 804-17-00100 | Construction Site Survey | LUMP | 1 |
| 0048 | 804-18-00100 | Vibration Monitoring | DAY | 2 |
| 0049 | 805-01-00300 | Class A1 Concrete (Bent Cap) | CUYD | 19.08 |
| 0050 | 805-18-00100 | Concrete Finish (Class 2 Rubbed Finish) | SQFT | 410 |
| 0051 | 806-01-00100 | Deformed Reinforcing Steel | LB | 2,314 |
| 0052 | 807-02-00100 | Structural Metalwork (Anchor Bolts) | LUMP | 1 |
| 0053 | NS-201-00001 | Tree and Stump Removal (<= 36" Diameter) | EACH | 3 |
| 0054 | NS-502-05125 | Shared-Use Path (Asphalt Concrete) (5" Thick) | SQYD | 4,330 |
| 0055 | NS-706-00440 | Shared-Use Path (Portland Cement Concrete) (6" Thick) | SQYD | 258 |
| 0056 | NS-736-00210 | Rectangular Rapid Flashing Beacon Assembly Pair (Double Sided) | EACH | 2 |
| 0057 | TS-700-00010 | Benches (Park) (6' Metal) | EACH | 8 |
| 0058 | TS-700-02080 | Bollard (6") | EACH | 4 |
| 0059 | TS-705-00005 | Wood Fence (10' HEIGHT) | LF | 80 |
| 0060 | TS-707-23060 | Wheel Stops | EACH | 20 |
| 0061 | TS-800-00100 | Pedestrian Bridge (12' WIDE) (PREFABRICATED) | LUMP | 1 |
| 0062 | TS-800-00150 | Aluminum Pedestrian Ramp (12' Wide) (Prefabricated) | EACH | 2 |
| 0063 | TS-822-09105 | Trenching and Backfilling | LNFT | 6,027 |
| 0064 | TS-822-09118 | Conduit (PVC/HDPE) (2" Schedule 40) | LNFT | 5,547 |
| 0065 | TS-822-09118 | Conduit (PVC/HDPE) (2" Schedule 80) | LNFT | 794 |
| 0066 | TS-822-09119 | Conductors (2 #12, 1 #8 GRD THWN) | LNFT | 1,589 |
| 0067 | TS-822-09119 | Conductors (2 #2, 1 #8 GND THWM) | LNFT | 2,861 |
| 0068 | TS-822-09119 | Conductors (2 #8, 1 #8 GND THWN) | LNFT | 2,173 |
| 0069 | TS-822-09134 | Light Pole (Type A - 14') (Alum) (Banner Arms) | EACH | 39 |
| 0070 | TS-822-09134 | Light Pole (Type B - 16') (Alum) (Banner Arms) | EACH | 14 |
| 0071 | TS-822-09158 | Luminaire (LED) (4K) (IES Type V Distr.) (Acorn) | EACH | 53 |
| 0072 | TS-822-09160 | Electrical Service Point (Structure) | EACH | 1 |
| 0073 | TS-822-09164 | Underground Junction Box (11" x 18") | EACH | 7 |
| 0074 | TS-822-09172 | Modular Breakaway Cable System | EACH | 20 |
| 0075 | TS-822-09174 | Disconnect (Service) | EACH | 1 |
| 0076 | TS-822-09176 | Duct Marker (Concrete) | EACH | 20 |
| 0077 | TS-822-09178 | Underground Marker Tape (6") (Detectable) | LNFT | 5,670 |