Line Number | Item | Description | Unit | Quantity |
| 0001 | 201-01-00100 | Clearing and Grubbing | LUMP | 1 |
| 0002 | 202-01-00100 | Removal of Structures and Obstructions | LUMP | 1 |
| 0003 | 202-02-02000 | Removal of Asphalt Drives | SQYD | 45 |
| 0004 | 202-02-03000 | Removal of Base – Soil Cement, Asphalt, or BCS | SQYD | 3,115.2 |
| 0005 | 202-02-03030 | Removal of Pavement Structure | SQYD | 665.7 |
| 0006 | 202-02-06100 | Removal of Concrete Walks and Drives | SQYD | 397 |
| 0007 | 202-02-40100 | Removal of Traffic Signal Equipment | LUMP | 1 |
| 0008 | 202-03-00010 | Relocation of Signal Heads | EACH | 11 |
| 0009 | 203-01-00100 | General Excavation | CUYD | 17,441 |
| 0010 | 203-03-00100 | Embankment | CUYD | 3,210 |
| 0011 | 204-02-00100 | Temporary Hay Bales | EACH | 30 |
| 0012 | 204-06-00100 | Temporary Silt Fencing | LNFT | 6,490 |
| 0013 | 302-02-10000 | Class II Base Course (10" Thick) | SQYD | 17,132.6 |
| 0014 | 305-01-04020 | Subgrade Layer (12" Thick) (Treated) | SQYD | 17,135 |
| 0015 | 402-01-00101 | Traffic Maintenance Surfacing (Aggregate) (Vehicular Measurement) | CUYD | 3,500 |
| 0016 | 402-02-00101 | Traffic Maintenance Surfacing (Hard) | SQYD | 1,750 |
| 0017 | 502-01-00100 | Asphalt Concrete | TON | 7,415.5 |
| 0018 | 502-01-00200 | Asphalt Concrete, Drives, Turnouts and Miscellaneous | TON | 108.7 |
| 0019 | 509-01-00100 | Milling Asphalt Pavement | SQYD | 15,765 |
| 0020 | 509-02-00100 | Contractor Retained Reclaimed Asphalt Pavement | CUYD | -907 |
| 0021 | 510-01-00100 | Pavement Patching (6" Minimum Thickness) | SQYD | 50 |
| 0022 | 510-01-00102 | Pavement Patching (8" Minimum Thickness) | SQYD | 100 |
| 0023 | 510-01-00104 | Pavement Patching (10" Minimum Thickness) | SQYD | 250 |
| 0024 | 601-01-00100 | Portland Cement Concrete Pavement (8" Thick) | SQYD | 745.2 |
| 0025 | 602-05-03120 | Full Depth Patching of Jointed Concrete Pavement (48.1 square yards and over) (8" Thick) | SQYD | 250 |
| 0026 | 701-03-01042 | Storm Drain Pipe (24" RCP/RPVCP) | LNFT | 896 |
| 0027 | 701-05-01046 | Side Drain Pipe (18" RCP/RPVCP) | LNFT | 224 |
| 0028 | 701-05-01069 | Side Drain Pipe (24" RCP/RPVCP) | LNFT | 144 |
| 0029 | 701-06-00020 | Side Drain Pipe Arch (18" Equiv. RCPA) | LNFT | 56 |
| 0030 | 701-10-01100 | Reinforced Concrete Pipe (Extension) (36") | LNFT | 5 |
| 0031 | 701-15-00100 | Concrete Collar | EACH | 1 |
| 0032 | 702-03-00100 | Catch Basins (CB-01) | EACH | 4 |
| 0033 | 702-03-00500 | Catch Basins (CB-06) | EACH | 1 |
| 0034 | 702-03-01000 | Catch Basins (CB-2TOP02) | EACH | 1 |
| 0035 | 706-02-00200 | Concrete Drive (6" Thick) | SQYD | 21.6 |
| 0036 | 706-03-00100 | Incidental Concrete Paving (4" Thick) | SQYD | 287.4 |
| 0037 | 707-01-00100 | Concrete Curb | LNFT | 1,042.5 |
| 0038 | 707-03-00100 | Combination Concrete Curb and Gutter | LNFT | 668.2 |
| 0039 | 713-01-00100 | Temporary Signs and Barricades | LUMP | 1 |
| 0040 | 713-02-00300 | Temporary Pavement Markings (8" Width) | LNFT | 3,928 |
| 0041 | 713-02-00500 | Temporary Pavement Markings (24" Width) | LNFT | 1,138 |
| 0042 | 713-03-01000 | Temporary Pavement Markings (Broken Line) (4" Width) (4' Length) | MILE | 1.202 |
| 0043 | 713-03-02000 | Temporary Pavement Markings (Broken Line) (4" Width) (10' Length) | MILE | 0.7 |
| 0044 | 713-04-01000 | Temporary Pavement Markings (Solid Line) (4" Width) | MILE | 7.587 |
| 0045 | 713-05-00200 | Temporary Pavement Legends & Symbols (Arrow - Double) | EACH | 2 |
| 0046 | 713-05-00220 | Temporary Pavement Legends & Symbols (Arrow - Left Turn) | EACH | 14 |
| 0047 | 713-05-00230 | Temporary Pavement Legends & Symbols (Arrow - Right Turn) | EACH | 9 |
| 0048 | 713-05-00300 | Temporary Pavement Legends & Symbols (ONLY) | EACH | 6 |
| 0049 | 713-06-00200 | Temporary Reflectorized Raised Pavement Markers (Tabs) | EACH | 189 |
| 0050 | 713-11-00100 | Portable Changeable Message Signs | EACH | 2 |
| 0051 | 716-01-00100 | Mulch (Vegetative) | TON | 13.5 |
| 0052 | 717-01-00100 | Seeding | LB | 409.4 |
| 0053 | 718-01-00100 | Fertilizer | LB | 13,658.7 |
| 0054 | 720-01-01000 | Erosion Control System (Slope Protection) (Type A) | SQYD | 2,786.1 |
| 0055 | 720-01-01020 | Erosion Control System (Slope Protection) (Type B) | SQYD | 22.9 |
| 0056 | 720-01-02000 | Erosion Control System, Flexible (Channel Liner) (Type C) | SQYD | 44.4 |
| 0057 | 720-01-02020 | Erosion Control System, Flexible (Channel Liner) (Type D) | SQYD | 307.5 |
| 0058 | 720-01-02040 | Erosion Control System, Flexible (Channel Liner) (Type E) | SQYD | 22.2 |
| 0059 | 726-01-00100 | Bedding Material | CUYD | 148.5 |
| 0060 | 727-01-00100 | Mobilization | LUMP | 1 |
| 0061 | 729-01-00100 | Sign (Type A) | SQFT | 247.3 |
| 0062 | 729-02-00100 | Sign (Type B) | SQFT | 15.4 |
| 0063 | 729-19-00200 | Dead End Road Installations (Type B) | EACH | 5 |
| 0064 | 729-22-00100 | Square Tubing Post with 2-1/4" Anchor | EACH | 32 |
| 0065 | 731-02-00100 | Reflectorized Raised Pavement Markers | EACH | 939 |
| 0066 | 732-01-01040 | Plastic Pavement Striping (8" Width) (Thermoplastic 90 mil) | LNFT | 2,780 |
| 0067 | 732-01-01080 | Plastic Pavement Striping (24" Width) (Thermoplastic 90 mil) | LNFT | 2,668 |
| 0068 | 732-01-02080 | Plastic Pavement Striping (24" Width) (Thermoplastic 125 mil) | LNFT | 524 |
| 0069 | 732-02-02000 | Plastic Pavement Striping (Solid Line) (4" Width) (Thermoplastic 90 mil) | MILE | 4.054 |
| 0070 | 732-03-02000 | Plastic Pavement Striping (Broken Line) (4" Width) (Thermoplastic 90 mil) | MILE | 1.08 |
| 0071 | 732-03-02030 | Plastic Pavement Striping (Dotted Line)(8" W)(2' L)(Thermo 90 mil) | MILE | 0.334 |
| 0072 | 732-04-01040 | Plastic Pavement Legends and Symbols (Arrow - Double) | EACH | 2 |
| 0073 | 732-04-01080 | Plastic Pavement Legends and Symbols (Arrow - Left Turn) | EACH | 23 |
| 0074 | 732-04-01100 | Plastic Pavement Legends and Symbols (Arrow - Right Turn) | EACH | 16 |
| 0075 | 732-04-15020 | Plastic Pavement Legends and Symbols (ONLY) | EACH | 10 |
| 0076 | 732-05-00100 | Removal of Existing Markings | MILE | 0.455 |
| 0077 | 735-01-00100 | Mailboxes | EACH | 1 |
| 0078 | 735-02-00100 | Mailbox Supports (Single) | EACH | 1 |
| 0079 | 736-01-00100 | Trenching and Backfilling | LNFT | 170 |
| 0080 | 736-03-00100 | Jacking or Boring | LNFT | 365 |
| 0081 | 736-04-10500 | Signal Pole (Single Mast Arm, 50ft) | EACH | 4 |
| 0082 | 736-05-30000 | Signal Heads (3 Section, 12 inch Led Lens, R, Y, G) | EACH | 7 |
| 0083 | 736-05-31001 | Signal Heads (3 Sec, 12 inch Led Lens, LT. R, LT. Y, LT. G) | EACH | 3 |
| 0084 | 736-05-41000 | Signal Heads (4 Section, 12" Led Lens, R, Y, LT. G, G) | EACH | 1 |
| 0085 | 736-05-41200 | Signal Heads (4 Section, 12 inch Led Lens, LT. R, LT. Y, FLT. Y, LT. G) | EACH | 1 |
| 0086 | 736-06-00100 | Signal Service | EACH | 1 |
| 0087 | 736-06-00500 | Signal Service Pedestal Disconnect | EACH | 1 |
| 0088 | 736-08-00102 | Signal Controller (980 ATC, Type 2)(Furnish & Install) | EACH | 1 |
| 0089 | 736-10-00200 | Underground Junction Box (Type E) | EACH | 1 |
| 0090 | 736-10-00300 | Underground Junction Box (Type F) | EACH | 3 |
| 0091 | 736-10-00400 | Underground Junction Box (Type G) | EACH | 1 |
| 0092 | 736-11-00200 | Conduit (2" HDPE, Schedule 80) | LNFT | 70 |
| 0093 | 736-11-00300 | Conduit (3" HDPE, Schedule 80) | LNFT | 585 |
| 0094 | 736-12-03006 | Conductor (3c, 6 gauge / #6 awg) | LNFT | 70 |
| 0095 | 736-12-06014 | Conductor (6c, #14 awg) | LNFT | 550 |
| 0096 | 736-12-10014 | Conductor (10c, #14 awg) | LNFT | 1,885 |
| 0097 | 736-15-03600 | Signal Support (Foundation, 36 inch Minimum Diameter) | EACH | 4 |
| 0098 | 740-01-00100 | Construction Layout | LUMP | 1 |
| 0099 | NS-500-00340 | Saw Cutting Asphalt Concrete Pavement | INLF | 5,749 |
| 0100 | NS-600-00220 | Saw Cutting Portland Cement Concrete Pavement | INLF | 1,073 |
| 0101 | NS-702-00101 | Paved Gutter Drain (Single) | EACH | 2 |
| 0102 | NS-736-00120 | Signal Radar Vehicle Detection Sensor (Stop Bar) | EACH | 4 |
| 0103 | NS-736-00122 | Signal Radar Vehicle Detection System Cabinet Interface Unit (CIU) | EACH | 1 |
| 0104 | NS-736-00123 | Signal Radar Vehicle Detection (Cable) | LNFT | 930 |