Line Number | Item | Description | Unit | Quantity |
| 0001 | 202-01-00100 | Removal of Structures and Obstructions | LUMP | 1 |
| 0002 | 202-02-00030 | Removal of Removal of existing striping (at driveways) | LNFT | 584 |
| 0003 | 202-02-06140 | Removal of Curbs (Concrete) | LNFT | 53.5 |
| 0004 | 202-02-40100 | Removal of Traffic Signal Equipment | LUMP | 1 |
| 0005 | 202-03-38000 | Relocation of Sign | EACH | 7 |
| 0006 | 204-02-00100 | Temporary Hay Bales | EACH | 32 |
| 0007 | 204-06-00100 | Temporary Silt Fencing | LNFT | 50 |
| 0008 | 706-01-00300 | Concrete Walk (6" Thick) | SQYD | 1,043.3 |
| 0009 | 707-01-00100 | Concrete Curb | LNFT | 165 |
| 0010 | 713-01-00100 | Temporary Signs and Barricades | LUMP | 1 |
| 0011 | 714-01-00100 | Slab Sodding (Bermuda Grass) | SQYD | 100 |
| 0012 | 723-02-00100 | Granular Material (Vehicular Measurement) | CUYD | 100 |
| 0013 | 727-01-00100 | Mobilization | LUMP | 1 |
| 0014 | 729-01-00102 | Sign (Type A)(Furnish and Install) | SQFT | 32.5 |
| 0015 | 732-01-02040 | Plastic Pavement Striping (8" Width) (Thermoplastic 125 mil) | LNFT | 337.2 |
| 0016 | 736-01-00100 | Trenching and Backfilling | LNFT | 65 |
| 0017 | 736-03-00100 | Jacking or Boring | LNFT | 262 |
| 0018 | 736-04-00001 | Signal Pole (Pedestal Pole) | EACH | 8 |
| 0019 | 736-08-00102 | Signal Controller (980 ATC, Type 2)(Furnish & Install) (Install Only. City of Kenner Will Furnish.) | EACH | 1 |
| 0020 | 736-10-00300 | Underground Junction Box (Type F) | EACH | 5 |
| 0021 | 736-11-00200 | Conduit (2" HDPE, Schedule 80) | LNFT | 130 |
| 0022 | 736-11-00300 | Conduit (3" HDPE, Schedule 80) | LNFT | 300 |
| 0023 | 736-12-02014 | Conductor (2c, #14 awg) | LNFT | 860 |
| 0024 | 736-12-06014 | Conductor (6c, #14 awg) | LNFT | 915 |
| 0025 | 736-15-02400 | Signal Support (Foundation, 24 inch Minimum Diameter) | EACH | 8 |
| 0026 | 736-21-00000 | LED Pedestrian Countdown Signal Head | EACH | 8 |
| 0027 | 740-01-00100 | Construction Layout | LUMP | 1 |
| 0028 | NS-736-00130 | TS-2 Traffic Signal Cabinet (Ground Mounted) | EACH | 1 |
| 0029 | NS-736-00135 | 2-Wire Accessible Pedestrian Pushbutton Detectors | EACH | 8 |
| 0030 | NS-736-00136 | 2-Wire Accessible Pedestrian Pushbutton Cabinet Control | EACH | 1 |
| 0031 | TS-736-00320 | Traffic Controller Cabinet Foundation and Access Platform | LS | 1 |
| 0032 | TS-741-00100 | Fire Hydrant Assembly | EACH | 1 |
| 0033 | TS-741-01090 | Water Main (6" PVC) (PVC/C-900 Pipe) | LNFT | 7 |
| 0034 | TS-741-01110 | Water Main (12" PVC) (PVC/C-900 Pipe) | LNFT | 10 |
| 0035 | TS-741-10023 | Adjust Valve Boxes | EACH | 3 |
| 0036 | TS-741-11201 | Ductile Iron Fittings | LB | 150 |
| 0037 | TS-741-60060 | Gate Valve and Valve Box (6") | EACH | 1 |
| 0038 | TS-741-70110 | Pipe Restraints (6") | EACH | 3 |
| 0039 | TS-741-70114 | Pipe Restraints (12") | EACH | 6 |
| 0040 | TS-741-70123 | Transitional Coupling (12") | EACH | 2 |