Line Number | Item | Description | Unit | Quantity |
0001 | 201-01-00100 | Clearing and Grubbing | LUMP | 1 |
0002 | 202-01-00100 | Removal of Structures and Obstructions | LUMP | 1 |
0003 | 202-02-02000 | Removal of Asphalt Drives | SQYD | 499 |
0004 | 202-02-06100 | Removal of Concrete Walks and Drives | SQYD | 1,706 |
0005 | 202-02-06102 | Removal of Incidental Concrete Paving | SQYD | 55 |
0006 | 203-02-00100 | Drainage Excavation | CUYD | 883 |
0007 | 203-04-00200 | Nonplastic Embankment (Sand) | CUYD | 542 |
0008 | 203-05-00100 | Excavation and Embankment | LUMP | 1 |
0009 | 204-02-00100 | Temporary Hay Bales | EACH | 198 |
0010 | 401-02-00100 | Aggregate Surface Course (Adjusted Vehicular Measurement) | CUYD | 297.7 |
0011 | 502-01-00200 | Asphalt Concrete, Drives, Turnouts and Miscellaneous | TON | 165 |
0012 | 602-05-02200 | Full Depth Patching of Jointed Concrete Pavement (16.1 square yards to 48.0 square yards) (10" Thick) | SQYD | 48.2 |
0013 | 701-03-01022 | Storm Drain Pipe (18" RCP/RPVCP) | LNFT | 183 |
0014 | 701-03-01042 | Storm Drain Pipe (24" RCP/RPVCP) | LNFT | 688 |
0015 | 701-03-01062 | Storm Drain Pipe (30" RCP/RPVCP) | LNFT | 401 |
0016 | 701-03-01082 | Storm Drain Pipe (36" RCP/RPVCP) | LNFT | 2,664 |
0017 | 701-12-01060 | Corrugated Metal Pipe (Extension) (24") | LNFT | 5 |
0018 | 701-15-00100 | Concrete Collar | EACH | 1 |
0019 | 702-02-00100 | Manholes (MH-06) | EACH | 5 |
0020 | 702-03-00100 | Catch Basins (CB-01) | EACH | 15 |
0021 | 702-03-01100 | Catch Basins (CB-SD02) | EACH | 18 |
0022 | 706-01-00100 | Concrete Walk (4" Thick) | SQYD | 943.5 |
0023 | 706-02-00200 | Concrete Drive (6" Thick) | SQYD | 1,744 |
0024 | 706-03-00300 | Incidental Concrete Paving (6" Thick) | SQYD | 1,625.7 |
0025 | 706-04-00110 | Curb Ramps Type 3 | SQYD | 56.7 |
0026 | 707-01-00100 | Concrete Curb | LNFT | 658.5 |
0027 | 712-05-00100 | Cabled Articulated Concrete Block Mattress | SQYD | 595 |
0028 | 713-01-00100 | Temporary Signs and Barricades | LUMP | 1 |
0029 | 726-01-00100 | Bedding Material | CUYD | 463.7 |
0030 | 727-01-00100 | Mobilization | LUMP | 1 |
0031 | 732-01-02080 | Plastic Pavement Striping (24" Width) (Thermoplastic 125 mil) | LNFT | 22 |
0032 | 732-05-00100 | Removal of Existing Markings | MILE | 0.013 |
0033 | 740-01-00100 | Construction Layout | LUMP | 1 |
0034 | 740-02-00100 | Utility Oversight and Coordination | LUMP | 1 |
0035 | 741-20-01120 | Water Main (10" PVC) | LNFT | 1,010 |
0036 | 741-22-00500 | Tapping Sleeve and Valve (10") | EACH | 8 |
0037 | 741-23-01120 | Insertion Valve (10") | EACH | 8 |
0038 | 741-33-00100 | Adjust Service Connection (20’ or less) | EACH | 15 |
0039 | 742-02-00200 | Sanitary Sewer Force Main Pipe 20" PVC | LNFT | 375 |
0040 | TS-714-00100 | Slab Sodding (Empire Zoysia) | SQYD | 8,991 |
0041 | TS-741-10042 | Plug and Abandon Water Main | EACH | 16 |
0042 | TS-741-23020 | Insertion Valve (20”) | EACH | 8 |
0043 | TS-741-60029 | Tapping Sleeve, Valve and Box 20" | EACH | 8 |
0044 | TS-742-00005 | Plug and Abandon Sewer Force Main | EACH | 16 |