Line Number | Item | Description | Unit | Quantity |
| 0001 | 202-02-02020 | Removal of Asphalt Pavement | SQYD | 388 |
| 0002 | 202-02-06060 | Removal of Concrete Catch Basin | EACH | 1 |
| 0003 | 202-02-06080 | Removal of Concrete Combination Curb and Gutter | LNFT | 336 |
| 0004 | 202-02-06100 | Removal of Concrete Walks and Drives | SQYD | 99.1 |
| 0005 | 202-02-06140 | Removal of Curbs (Concrete) | LNFT | 8.9 |
| 0006 | 202-02-38200 | Removal of Signs | EACH | 11 |
| 0007 | 202-02-38220 | Removal of Sign Supports | EACH | 5 |
| 0008 | 202-03-38000 | Relocation of Sign | EACH | 4 |
| 0009 | 203-05-00100 | Excavation and Embankment | LUMP | 1 |
| 0010 | 204-02-00100 | Temporary Hay Bales | EACH | 42 |
| 0011 | 204-06-00100 | Temporary Silt Fencing | LNFT | 190 |
| 0012 | 302-02-06020 | Class II Base Course (6" Thick) (Crushed Stone) | SQYD | 335 |
| 0013 | 510-01-00200 | Pavement Patching (12" Minimum Thickness) | SQYD | 17.1 |
| 0014 | 601-01-10000 | Portland Cement Concrete Pavement (Colored) (6" Thick)(Red Brick) | SQYD | 150.9 |
| 0015 | 701-03-01002 | Storm Drain Pipe (15" RCP/RPVCP) | LNFT | 90 |
| 0016 | 701-17-00100 | Trench Excavation Safety Protection (Depth >5 feet) | LNFT | 30 |
| 0017 | 702-03-00100 | Catch Basins (CB-01) | EACH | 2 |
| 0018 | 702-03-00500 | Catch Basins (CB-06) | EACH | 2 |
| 0019 | 705-06-00500 | Chain Link Fence (8 Foot Height) | LNFT | 190 |
| 0020 | 706-01-00100 | Concrete Walk (4" Thick) | SQYD | 116.1 |
| 0021 | 706-03-00300 | Incidental Concrete Paving (6" Thick) | SQYD | 276.2 |
| 0022 | 706-04-00110 | Curb Ramps Type 1 | SQYD | 115.2 |
| 0023 | 706-04-00110 | Curb Ramps Type 7 | SQYD | 13.3 |
| 0024 | 707-01-00100 | Concrete Curb | LNFT | 540.2 |
| 0025 | 707-03-00100 | Combination Concrete Curb and Gutter | LNFT | 264.2 |
| 0026 | 713-01-00100 | Temporary Signs and Barricades | LUMP | 1 |
| 0027 | 714-01-00100 | Slab Sodding (Bermuda Grass) | SQYD | 250 |
| 0028 | 726-01-00100 | Bedding Material | CUYD | 18.2 |
| 0029 | 727-01-00100 | Mobilization | LUMP | 1 |
| 0030 | 728-01-00200 | Jacked or Bored Pipe (4") (PVC/HDPE) | LNFT | 215 |
| 0031 | 729-01-00100 | Sign (Type A) | SQFT | 143.3 |
| 0032 | 729-13-00100 | Mounting (Bridge Fascia Mounted) | EACH | 4 |
| 0033 | 729-22-00200 | Square Tubing Post with 2-1/4" Omni-Directional Anchor | EACH | 5 |
| 0034 | 731-02-00100 | Reflectorized Raised Pavement Markers | EACH | 38 |
| 0035 | 732-01-01000 | Plastic Pavement Striping (4" Width) (Thermoplastic 90 mil) | LNFT | 1,381 |
| 0036 | 732-01-02080 | Plastic Pavement Striping (24" Width) (Thermoplastic 125 mil) | LNFT | 172 |
| 0037 | 732-02-02000 | Plastic Pavement Striping (Solid Line) (4" Width) (Thermoplastic 90 mil) | MILE | 0.567 |
| 0038 | 732-05-00100 | Removal of Existing Markings | MILE | 0.139 |
| 0039 | 736-01-00100 | Trenching and Backfilling | LNFT | 185 |
| 0040 | 736-04-00001 | Signal Pole (Pedestal Pole) | EACH | 4 |
| 0041 | 736-10-00200 | Underground Junction Box (Type E) | EACH | 8 |
| 0042 | 736-10-00300 | Underground Junction Box (Type F) | EACH | 4 |
| 0043 | 736-11-00200 | Conduit (2" HDPE, Schedule 80) | LNFT | 340 |
| 0044 | 736-12-03014 | Conductor (3c, #14 awg) | LNFT | 340 |
| 0045 | 736-15-02400 | Signal Support (Foundation, 24 inch Minimum Diameter) | EACH | 4 |
| 0046 | 736-22-00000 | Pedestrian Push Button | EACH | 4 |
| 0047 | 740-01-00100 | Construction Layout | LUMP | 1 |
| 0048 | NS-201-00001 | Tree and Stump Removal (<= 36" Diameter) | EACH | 2 |
| 0049 | NS-500-00340 | Saw Cutting Asphalt Concrete Pavement | INLF | 3,627 |
| 0050 | NS-600-00220 | Saw Cutting Portland Cement Concrete Pavement | INLF | 88 |
| 0051 | NS-700-00100 | Trench Drains | EACH | 1 |
| 0052 | NS-736-00211 | Rectangular Rapid Flashing Beacon Assembly Pair (Single Sided) (SOLAR POWER) | EACH | 4 |
| 0053 | NS-736-00212 | Rectangular Rapid Flashing Beacon Assembly Pair (Double Sided) (SOLAR POWER) | EACH | 4 |
| 0054 | NS-ITS-06120 | Pullbox, Structure Mount, Furnish & Install - New | EACH | 6 |
| 0055 | TS-822-00105 | LED Handrail Mount Lighting Assembly | LNFT | 490 |
| 0056 | TS-822-09110 | Conduit w Conductors (PVC/HDPE) (1")(3#10) | LNFT | 35 |
| 0057 | TS-822-09110 | Conduit w Conductors (PVC/HDPE) (1")(3#12) | LNFT | 110 |
| 0058 | TS-822-09110 | Conduit w Conductors (PVC/HDPE) (1")(3#8) | LNFT | 80 |
| 0059 | TS-822-09112 | Conduit w Conductors (Rigid Galv Steel) (1")(3#10) | LNFT | 250 |
| 0060 | TS-822-09112 | Conduit w Conductors (Rigid Galv Steel) (1")(3#10, 3#12) | LNFT | 6 |
| 0061 | TS-822-09112 | Conduit w Conductors (Rigid Galv Steel) (1")(3#12) | LNFT | 80 |
| 0062 | TS-822-09112 | Conduit w Conductors (Rigid Galv Steel) (1")(3#8, 3#12) | LNFT | 6 |
| 0063 | TS-822-09112 | Conduit w Conductors (Rigid Galv Steel) (1.5")(3#4) | LNFT | 28 |
| 0064 | TS-822-09160 | Electrical Service Point (Structure) | EACH | 2 |
| 0065 | TS-822-09170 | Service Pole | EACH | 2 |
| 0066 | TS-822-09174 | Disconnect (Meter or SPC) | EACH | 2 |