Line Number | Item | Description | Unit | Quantity |
| 0001 | 202-02-00010 | Removal of Removal of Bridge Component (Unit 1,2 and 4 Existing curb and median removal) | EACH | 43 |
| 0002 | 202-02-00010 | Removal of Removal of Bridge Component (Unit 3 Existing barrier and deck removal) | EACH | 6 |
| 0003 | 706-03-00300 | Incidental Concrete Paving (6" Thick) | SQYD | 24 |
| 0004 | 713-01-00100 | Temporary Signs and Barricades | LUMP | 1 |
| 0005 | 713-02-00100 | Temporary Pavement Markings (4" Width) | LNFT | 34,172 |
| 0006 | 713-03-01020 | Temporary Pavement Markings (Broken Line) (4" W) (4' L) (Type 1 Removable) | MILE | 0.727 |
| 0007 | 713-04-01020 | Temporary Pavement Markings (Solid Line) (4"Width) (Type 1 Removable) | MILE | 4 |
| 0008 | 713-06-00100 | Temporary Reflectorized Raised Pavement Markers | EACH | 25,119 |
| 0009 | 713-07-00100 | Temporary Precast Concrete Barrier (Contractor Furnished) | EACH | 100 |
| 0010 | 727-01-00100 | Mobilization | LUMP | 1 |
| 0011 | 731-02-00100 | Reflectorized Raised Pavement Markers | EACH | 5,786 |
| 0012 | 732-01-02080 | Plastic Pavement Striping (24" Width) (Thermoplastic 125 mil) | LNFT | 537 |
| 0013 | 732-02-02000 | Plastic Pavement Striping (Solid Line) (4" Width) (Thermoplastic 90 mil) | MILE | 11.732 |
| 0014 | 732-02-02040 | Plastic Pavement Striping (Solid Line) (8" Width) (Thermoplastic 90 mil) | MILE | 0.477 |
| 0015 | 732-03-02000 | Plastic Pavement Striping (Broken Line) (4" Width) (Thermoplastic 90 mil) | MILE | 5.843 |
| 0016 | 732-03-02002 | Plastic Pav't Striping (Broken) (4" Width) (Thermo 90 mil)(Black and White Cont) | MILE | 4.254 |
| 0017 | 732-03-02040 | Plastic Pavement Striping (Dotted Line)(8" W)(3' L)(Thermo 90 mil) | MILE | 0.224 |
| 0018 | 732-04-01120 | Plastic Pavement Legends and Symbols (Arrow - Merge) | EACH | 2 |
| 0019 | 732-05-00100 | Removal of Existing Markings | MILE | 5.007 |
| 0020 | 740-01-00100 | Construction Layout | LUMP | 1 |
| 0021 | 822-11-00100 | Removal and Disposal of Electrical Equipment | LUMP | 1 |
| 0022 | 822-13-00100 | Removal and Disposal of Light Pole Foundation (Existing foundation removal to a minimum of 24" below grade and backfilling) | EACH | 24 |
| 0023 | NS-700-00260 | Temporary Queue Detection System Deployment | LUMP | 1 |
| 0024 | NS-700-00270 | Temporary Queue Detection - PCMS | EACH | 5 |
| 0025 | NS-700-00280 | Temporary Queue Detection - PQS | EACH | 8 |
| 0026 | NS-700-00290 | Temporary Queue Detection - Static Warning Signage | EACH | 4 |
| 0027 | NS-700-00810 | Impact Attenuator (Construction Zone)(Test Level 3) | EACH | 2 |
| 0028 | TS-822-09105 | Trenching and Backfilling | LNFT | 150 |
| 0029 | TS-822-09110 | Conduit w Conductors (PVC/HDPE) (1") (2#12,1#12 Ground) | LNFT | 670 |
| 0030 | TS-822-09110 | Conduit w Conductors (PVC/HDPE) (1") (2#8, 1#8 Ground) | LNFT | 540 |
| 0031 | TS-822-09110 | Conduit w Conductors (PVC/HDPE) (1-1/2") (2#4, 1#4 Ground | LNFT | 500 |
| 0032 | TS-822-09110 | Conduit w Conductors (PVC/HDPE) (1-1/2") (2#8, 1#8 Ground | LNFT | 400 |
| 0033 | TS-822-09112 | Conduit w Conductors (Rigid Galv Steel) (1") (2#12, 1 #12 Ground) | LNFT | 500 |
| 0034 | TS-822-09112 | Conduit w Conductors (Rigid Galv Steel) (1-1/2") (2#4, 1#4 Ground) | LNFT | 850 |
| 0035 | TS-822-09113 | Conduit w Conductors (Liq Tight Flexible Metal) (1-1/2") (2#4, 1#4 Ground) | LNFT | 50 |
| 0036 | TS-822-09113 | Conduit w Conductors (Liq Tight Flexible Metal) l) (1") (2#12, 1 #12 Ground) | LNFT | 25 |
| 0037 | TS-822-09114 | Conduit w Conductors (Fiberglass) (1") (2#8, 1#8 Ground) | LNFT | 20 |
| 0038 | TS-822-09114 | Conduit w Conductors (Fiberglass) (1-1/2") (2#8, 1#8 Ground) | LNFT | 20 |
| 0039 | TS-822-09119 | Conductors (In Existing Conduit)(2#12, 1 #12 Ground) | LNFT | 400 |
| 0040 | TS-822-09119 | Conductors (In Existing Conduit)(2#8, 1#8 Ground) | LNFT | 8,460 |
| 0041 | TS-822-09119 | Conductors (2#4, 1#4 Ground) | LNFT | 7,650 |
| 0042 | TS-822-09130 | Light Pole (Steel) (Single Arm) (40' MH) (Steel) (6' Single Arm) | EACH | 8 |
| 0043 | TS-822-09131 | Light Pole (Steel) (Twin Arm) (35' MH) (Steel) (3’ Twin Arm) | EACH | 1 |
| 0044 | TS-822-09131 | Light Pole (Steel) (Twin Arm) (40' MH) (Steel) (3’ Twin Arm) | EACH | 49 |
| 0045 | TS-822-09131 | Light Pole (Steel) (Twin Arm) (40' MH) (Steel) (6' Twin Arm) | EACH | 24 |
| 0046 | TS-822-09150 | High Mast Luminaire Lowering Device Replacement | EACH | 2 |
| 0047 | TS-822-09155 | Luminaire (High Mast) (LED) (3K) | EACH | 12 |
| 0048 | TS-822-09156 | Luminaire (Roadway) (LED) (3K) | EACH | 156 |
| 0049 | TS-822-09160 | Electrical Service Point (Structure) | EACH | 4 |
| 0050 | TS-822-09164 | Underground Junction Box Polymer Concrete (11" x 18") | EACH | 24 |
| 0051 | TS-822-09164 | Underground Junction Box Polymer Concrete (13" x 24") | EACH | 5 |
| 0052 | TS-822-09168 | Structure Junction Box (Stainless Steel) (12"x 12"x24") (JBS3) | EACH | 50 |
| 0053 | TS-822-09172 | Modular Breakaway Cable System | EACH | 24 |
| 0054 | TS-822-09178 | Underground Marker Tape 6" | LNFT | 940 |