Line Number | Item | Description | Unit | Quantity |
| 0001 | 201-01-00100 | Clearing and Grubbing | LUMP | 1 |
| 0002 | 202-01-00100 | Removal of Structures and Obstructions | LUMP | 1 |
| 0003 | 202-02-06100 | Removal of Concrete Walks and Drives | SQYD | 2,035 |
| 0004 | 202-02-06140 | Removal of Curbs (Concrete) | LNFT | 618 |
| 0005 | 202-03-38000 | Relocation of Sign | EACH | 8 |
| 0006 | 203-07-00100 | Borrow (Vehicular Measurement) (Select Soils) | CUYD | 120 |
| 0007 | 204-02-00100 | Temporary Hay Bales | EACH | 80 |
| 0008 | 204-06-00100 | Temporary Silt Fencing | LNFT | 265 |
| 0009 | 402-01-00101 | Traffic Maintenance Surfacing (Aggregate) (Vehicular Measurement) | CUYD | 20 |
| 0010 | 702-04-00100 | Adjusting Manholes | EACH | 1 |
| 0011 | 705-06-00300 | Chain Link Fence (6-Foot Height) | LNFT | 52 |
| 0012 | 706-01-00100 | Concrete Walk (4" Thick) | SQYD | 2,612.2 |
| 0013 | 706-02-00200 | Concrete Drive (6" Thick) | SQYD | 1,962.2 |
| 0014 | 706-04-00110 | Curb Ramps (Type 2) | SQYD | 20.8 |
| 0015 | 706-04-00110 | Curb Ramps (Type 7) | SQYD | 319.2 |
| 0016 | 707-01-00100 | Concrete Curb (Barrier) | LNFT | 230 |
| 0017 | 713-01-00100 | Temporary Signs and Barricades (INCLUDES TEMPORARY BUSINESS ENTRANCES) | LUMP | 1 |
| 0018 | 716-01-00100 | Mulch (Vegetative) | TON | 1 |
| 0019 | 717-01-00100 | Seeding | LB | 15 |
| 0020 | 718-01-00100 | Fertilizer | LB | 15 |
| 0021 | 727-01-00100 | Mobilization | LUMP | 1 |
| 0022 | 740-01-00100 | Construction Layout | LUMP | 1 |
| 0023 | 741-35-00100 | Adjust Valve or Meter Box (METER BOX) | EACH | 9 |
| 0024 | 741-35-00100 | Adjust Valve or Meter Box (WATER VALVE) | EACH | 7 |
| 0025 | 810-04-00100 | Hand Railing | LNFT | 102 |
| 0026 | 822-01-00100 | Trenching and Backfilling | LNFT | 6,205 |
| 0027 | 822-02-00200 | Conduit w Conductors (PVC/HDPE) (1") (2 #10 + 2 #8 AWG THWN COPPER CONDUCTORS + 1 #10 AWG THWN COPPER GROUND) | LNFT | 190 |
| 0028 | 822-02-00200 | Conduit w Conductors (PVC/HDPE) (1") (4 #10 AWG THWN COPPER CONDUCTORS + 1 #10 AWG THWN COPPER GROUND) | LNFT | 8,955 |
| 0029 | 822-02-00500 | Conduit w Conductors (PVC/HDPE) (2") (SECONDARY SERVICE CONDUIT RISERS FOR SERVICE CONDUCTORS BY ENTERGY | LNFT | 18 |
| 0030 | 822-02-02200 | Conduit w Conductors (Rigid Galv Steel) (1") (2 #8 + 2 #10 AWG THWN COPPER CONDUTORS + 1 #10 AWG COPPER GROUND) | LNFT | 20 |
| 0031 | 822-02-02200 | Conduit w Conductors (Rigid Galv Steel) (1") (4 #10 AWG THWN COPPER CONDUCTORS + 1 #10 AWG COPPER GROUND) | LNFT | 550 |
| 0032 | 822-02-02500 | Conduit w Conductors (Rigid Galv Steel) (2") (ABOVE GRADE 2" RGS CONDUIT SERVICE CONDUCTORS BY ENTERGY) | LNFT | 25 |
| 0033 | 822-04-00100 | Jacked or Bored Casing (4" Dia) (PVC/HDPE) | LNFT | 2,940 |
| 0034 | 822-05-02100 | Light Pole (12') (Smooth Aluminum ) | EACH | 142 |
| 0035 | 822-07-02800 | Luminaire (IES Type "V")( 88 Watt) (LED) | EACH | 142 |
| 0036 | 822-08-00200 | Electrical Service Point (Structure) | EACH | 2 |
| 0037 | 822-22-00400 | Underground Marker Tape (6")(Non-Detectable) | LNFT | 6,205 |
| 0038 | NS-500-00340 | Saw Cutting Asphalt Concrete Pavement | INLF | 1,068 |
| 0039 | NS-600-00220 | Saw Cutting Portland Cement Concrete Pavement | INLF | 24,420 |
| 0040 | NS-700-00100 | Trench Drains | EACH | 2 |