Line Number | Item | Description | Unit | Quantity |
| 0001 | 201-01-00100 | Clearing and Grubbing | LUMP | 1 |
| 0002 | 202-01-00100 | Removal of Structures and Obstructions | LUMP | 1 |
| 0003 | 202-02-00010 | Removal of Temporary 4" Concrete Slab | EACH | 4 |
| 0004 | 202-02-02000 | Removal of Asphalt Drives | SQYD | 144 |
| 0005 | 202-02-02020 | Removal of Asphalt Pavement | SQYD | 5,316.2 |
| 0006 | 202-02-03000 | Removal of Base – Soil Cement, Asphalt, or BCS | SQYD | 5,316.2 |
| 0007 | 202-02-06020 | Removal of Concrete Box Culverts (8' x 3' x 30') | EACH | 1 |
| 0008 | 202-02-06040 | Removal of Concrete Box Headwall (Sta. 207+25) | EACH | 2 |
| 0009 | 202-02-32120 | Removal of Pipe (Side Drain) (According to Removal of Drainage Table) | LNFT | 181 |
| 0010 | 202-02-32140 | Removal of Pipe (Storm Drain) (According to Removal of Drainage Table) | LNFT | 15 |
| 0011 | 203-01-00100 | General Excavation (Roadway and Muck) | CUYD | 5,981 |
| 0012 | 203-03-00100 | Embankment | CUYD | 5,403 |
| 0013 | 203-04-00200 | Nonplastic Embankment (Sand) | CUYD | 19,002 |
| 0014 | 203-04-00200 | Nonplastic Embankment (Sand) (Surcharge) | CUYD | 6,264 |
| 0015 | 203-08-00100 | Geotextile Fabric | SQYD | 20,765 |
| 0016 | 203-11-00100 | Settlement Plate Installation and Monitoring | EACH | 19 |
| 0017 | 204-02-00100 | Temporary Hay Bales | EACH | 90 |
| 0018 | 204-06-00100 | Temporary Silt Fencing | LNFT | 7,375 |
| 0019 | 302-02-12070 | Class II Base Course (12" Thick) (Crushed Stone or Recycled Portland Cement Concrete) | SQYD | 10,082.7 |
| 0020 | 402-01-00101 | Traffic Maintenance Surfacing (Aggregate) (Vehicular Measurement) | CUYD | 50 |
| 0021 | 502-01-00100 | Asphalt Concrete | TON | 3,697.2 |
| 0022 | 502-01-00200 | Asphalt Concrete, Drives, Turnouts and Miscellaneous | TON | 868.8 |
| 0023 | 509-01-00100 | Milling Asphalt Pavement | SQYD | 4,547 |
| 0024 | 509-02-00100 | Contractor Retained Reclaimed Asphalt Pavement | CUYD | -252.6 |
| 0025 | 510-01-00102 | Pavement Patching (8" Minimum Thickness) | SQYD | 34.2 |
| 0026 | 510-02-00100 | Pavement Widening (4" Thick) | SQYD | 939 |
| 0027 | 510-02-00100 | Pavement Widening (8" Thick) | SQYD | 305.1 |
| 0028 | 701-02-01000 | Cross Drain Pipe Arch (24" Equiv. RCPA) | LNFT | 272 |
| 0029 | 701-02-01020 | Cross Drain Pipe Arch (30" Equiv. RCPA) | LNFT | 152 |
| 0030 | 701-03-01042 | Storm Drain Pipe (24" RCP/RPVCP) | LNFT | 197 |
| 0031 | 701-04-01020 | Storm Drain Pipe Arch (18" Equiv. RCPA) | LNFT | 274 |
| 0032 | 701-05-01045 | Side Drain Pipe (18" RCP/RPVCP/CPEPDW) | LNFT | 112 |
| 0033 | 701-06-00020 | Side Drain Pipe Arch (18" Equiv. RCPA) | LNFT | 160 |
| 0034 | 701-07-00600 | Yard Drain Pipe (15") | LNFT | 200 |
| 0035 | 702-03-00100 | Catch Basins (CB-01) | EACH | 1 |
| 0036 | 702-03-01000 | Catch Basins (CB-2TOP02) | EACH | 1 |
| 0037 | 704-03-00200 | Blocked Out Guard Rail - 31", (6'-3" Post Spacing) | LNFT | 50 |
| 0038 | 704-07-00200 | Guard Rail Transitions (Double Thrie Beam) | LNFT | 100 |
| 0039 | 704-10-00310 | Guard Rail End Treatment, NCHRP 350 - 31" (TL-3 Flared) | EACH | 4 |
| 0040 | 706-01-00100 | Concrete Walk (4" Thick) | SQYD | 17.4 |
| 0041 | 708-01-00100 | Right-of-Way Monument | EACH | 35 |
| 0042 | 708-02-00100 | Right-of-Way Monument Witness Post | EACH | 35 |
| 0043 | 713-01-00100 | Temporary Signs and Barricades | LUMP | 1 |
| 0044 | 713-03-01000 | Temporary Pavement Markings (Broken Line) (4" Width) (4' Length) | MILE | 0.259 |
| 0045 | 713-03-02000 | Temporary Pavement Markings (Broken Line) (4" Width) (10' Length) | MILE | 0.341 |
| 0046 | 713-04-01000 | Temporary Pavement Markings (Solid Line) (4" Width) | MILE | 0.341 |
| 0047 | 713-06-00100 | Temporary Reflectorized Raised Pavement Markers | EACH | 45 |
| 0048 | 713-08-00100 | Temporary Precast Concrete Barrier (Department Furnished) | EACH | 88 |
| 0049 | 716-01-00100 | Mulch (Vegetative) | TON | 16.3 |
| 0050 | 717-01-00100 | Seeding | LB | 279 |
| 0051 | 718-01-00100 | Fertilizer | LB | 9,305 |
| 0052 | 722-01-00100 | Project Site Laboratory | EACH | 1 |
| 0053 | 726-01-00100 | Bedding Material | CUYD | 105.1 |
| 0054 | 727-01-00100 | Mobilization | LUMP | 1 |
| 0055 | 729-01-00100 | Sign (Type A) | SQFT | 54 |
| 0056 | 729-02-00100 | Sign (Type B) | SQFT | 70 |
| 0057 | 729-16-00200 | Object Marker Assembly (Type 2) | EACH | 6 |
| 0058 | 729-16-00300 | Object Marker Assembly (Type 3) | EACH | 4 |
| 0059 | 729-22-00200 | Square Tubing Post with 2-1/4" Omni-Directional Anchor | EACH | 22 |
| 0060 | 731-02-00100 | Reflectorized Raised Pavement Markers | EACH | 157 |
| 0061 | 732-01-02080 | Plastic Pavement Striping (24" Width) (Thermoplastic 125 mil) | LNFT | 45 |
| 0062 | 732-02-02000 | Plastic Pavement Striping (Solid Line) (4" Width) (Thermoplastic 90 mil) | MILE | 2.368 |
| 0063 | 732-03-02000 | Plastic Pavement Striping (Broken Line) (4" Width) (Thermoplastic 90 mil) | MILE | 0.653 |
| 0064 | 735-01-00100 | Mailboxes | EACH | 2 |
| 0065 | 735-02-00100 | Mailbox Supports (Single) | EACH | 2 |
| 0066 | 740-01-00100 | Construction Layout | LUMP | 1 |
| 0067 | 802-03-00500 | Temporary Sheeting (PZ 35) | SQFT | 37,000 |
| 0068 | 805-01-01000 | Class A1 Concrete (Headwalls) (3'-0" x 18'-11") | CUYD | 3.93 |
| 0069 | 805-01-01000 | Class A1 Concrete (Headwalls) (3'-5" x 22'-1") | CUYD | 4.93 |
| 0070 | 806-01-00100 | Deformed Reinforcing Steel | LB | 498 |
| 0071 | 807-01-00800 | Structural Metalwork (Bollards) | LUMP | 1 |
| 0072 | NS-203-00014 | Wick Drains | LNFT | 678,022 |
| 0073 | NS-300-00060 | Geogrid | SQYD | 10,082.7 |
| 0074 | NS-500-00240 | Sawing and Sealing Transverse Joints in Asphalt Concrete Overlay | LNFT | 216 |
| 0075 | NS-500-00260 | Sawcuts in Asphalt Concrete Lifts | LNFT | 144 |
| 0076 | NS-500-00300 | Traffic Maintenance Asphalt Concrete | TON | 101 |
| 0077 | NS-500-00340 | Saw Cutting Asphalt Concrete Pavement | INLF | 20,415 |
| 0078 | NS-700-00810 | Impact Attenuator (Construction Zone)(Test Level 3) | EACH | 2 |
| 0079 | TS-741-00100 | Fire Hydrant Assembly | EACH | 5 |
| 0080 | TS-741-01100 | Water Main (8" PVC) (PVC/C-900 Pipe) | LNFT | 175 |
| 0081 | TS-741-01120 | Water Main (14") (PVC/C-900 Pipe) | LNFT | 202 |
| 0082 | TS-741-02090 | Water Main (14") (Ductile Iron Pipe) | LF | 50 |
| 0083 | TS-741-02091 | Water Main (16") (HDPE Pipe SDR 17) | LF | 2,416 |
| 0084 | TS-741-11201 | Ductile Iron Fittings | LB | 1,000 |
| 0085 | TS-741-60058 | Gate Valve and Valve Box (8") | EACH | 4 |
| 0086 | TS-741-60059 | Butterfly Valve and Valve Box (14") | EACH | 2 |
| 0087 | TS-741-70103 | Removal and Disposal of Existing AC Waterline (14") | LNFT | 60 |
| 0088 | TS-741-70112 | Pipe Restraints (8") | EACH | 12 |
| 0089 | TS-741-70115 | Pipe Restraints (14") | EACH | 14 |
| 0090 | TS-741-70122 | Transitional Coupling (8") | EACH | 2 |
| 0091 | TS-741-70125 | Transitional Coupling (14") | EACH | 2 |
| 0092 | TS-741-70126 | Transitional Couplings HDPE to PVC (16"x14") | EACH | 4 |