Line Number | Item | Description | Unit | Quantity |
| 0001 | 202-02-00050 | Removal of EXISTING ACCESS LADDERS ON BRIDGES A & B | LUMP | 1 |
| 0002 | 705-06-00400 | Chain Link Fence (7 Foot Height) | LNFT | 39 |
| 0003 | 705-07-02060 | 4-Foot Single Gates for Chain Link Fence (7-Foot Height) | EACH | 2 |
| 0004 | 713-01-00100 | Temporary Signs and Barricades | LUMP | 1 |
| 0005 | 713-11-00100 | Portable Changeable Message Signs | EACH | 4 |
| 0006 | 727-01-00100 | Mobilization | LUMP | 1 |
| 0007 | 740-01-00100 | Construction Layout | LUMP | 1 |
| 0008 | 807-01-00200 | Structural Metalwork (Grade 50) (Bridge A & B) | LUMP | 1 |
| 0009 | 807-01-00200 | Structural Metalwork (Grade 50) (Bridge C) | LUMP | 1 |
| 0010 | 807-01-00200 | Structural Metalwork (Grade 50) (Bridge D) | LUMP | 1 |
| 0011 | 807-02-00100 | Structural Metalwork (Anchor Bolts) (Bridge A & B) | LUMP | 1 |
| 0012 | 807-02-00100 | Structural Metalwork (Anchor Bolts) (Bridge C) | LUMP | 1 |
| 0013 | 807-02-00100 | Structural Metalwork (Anchor Bolts) (Bridge D) | LUMP | 1 |
| 0014 | 807-03-00100 | Structural Metalwork (Access System) (Bridge A & B) | LUMP | 1 |
| 0015 | 807-03-00100 | Structural Metalwork (Access System) (Bridge C) | LUMP | 1 |
| 0016 | 807-03-00100 | Structural Metalwork (Access System) (Bridge D) | LUMP | 1 |
| 0017 | 822-01-00100 | Trenching and Backfilling | LNFT | 545 |
| 0018 | 822-02-00100 | Conduit w Conductors (PVC/HDPE) (3/4") (1#2 BARE STRANDED GROUND) | LNFT | 30 |
| 0019 | 822-02-00200 | Conduit w Conductors (PVC/HDPE) (1") (2#10, 1#10, BARE STRANDED GROUND) | LNFT | 345 |
| 0020 | 822-02-00200 | Conduit w Conductors (PVC/HDPE) (1") (3#10, 1#10 BARE STRANDED GROUND) | LNFT | 290 |
| 0021 | 822-02-01100 | Conduit w Conductors (Rigid Alum) (3/4") (2#10, 1#10 INSULATED STRANDED GROUND) | LNFT | 4,020 |
| 0022 | 822-02-01100 | Conduit w Conductors (Rigid Alum) (3/4") (3#10, 1#10 INSULATED STRANDED GROUND) | LNFT | 2,420 |
| 0023 | 822-02-01100 | Conduit w Conductors (Rigid Alum) (3/4") (4#10, 1#10 INSULATED STRANDED GROUND) | LNFT | 1,105 |
| 0024 | 822-02-01200 | Conduit w Conductors (Rigid Alum) (1") (5#10, 1#10 INSULATED STRANDED GROUND) | LNFT | 1,520 |
| 0025 | 822-02-03100 | Conduit w Conductors (Liq Tight Flexible Metal) (3/4") (2#10, 1#10 INSULATED STRANDED GROUND) | LNFT | 40 |
| 0026 | 822-02-03100 | Conduit w Conductors (Liq Tight Flexible Metal) (3/4") (3#10, 1#10 INSULATED STRANDED GROUND) | LNFT | 40 |
| 0027 | 822-02-03100 | Conduit w Conductors (Liq Tight Flexible Metal) (3/4") (4#10, 1#10 INSULATED STRANDED GROUND) | LNFT | 80 |
| 0028 | 822-02-03200 | Conduit w Conductors (Liq Tight Flexible Metal) (1") (5#10, 1#10 INSULATED STRANDED GROUND) | LNFT | 80 |
| 0029 | 822-02-04200 | Conduit w Conductors (Fiberglass) (1") (2#10, 1#10 BARE STRANDED GROUND) | LNFT | 10 |
| 0030 | 822-02-04200 | Conduit w Conductors (Fiberglass) (1") (3#10, 1#10 BARE STRANDED GROUND) | LNFT | 20 |
| 0031 | 822-02-04200 | Conduit w Conductors (Fiberglass) (1") (4#10, 2#10 BARE STRANDED GROUND) | LNFT | 10 |
| 0032 | 822-03-00100 | Conductors (NAV LIGHT SOOW CABLE) | LNFT | 240 |
| 0033 | 822-04-00200 | Jacked or Bored Casing (6" Dia) (PVC/HDPE) | LNFT | 90 |
| 0034 | 822-07-02800 | Luminaire (CHANNEL LIGHT) | EACH | 8 |
| 0035 | 822-07-02800 | Luminaire (CHANNEL MARGIN LIGHT) | EACH | 16 |
| 0036 | 822-07-02800 | Luminaire (LAMP OUT INDICATOR) | EACH | 24 |
| 0037 | 822-09-00100 | Electrical System (Bridge A & B) | LUMP | 1 |
| 0038 | 822-09-00100 | Electrical System (Bridge C) | LUMP | 1 |
| 0039 | 822-09-00100 | Electrical System (Bridge D) | LUMP | 1 |
| 0040 | 822-09-00100 | Electrical System (MAINTAIN EXISTING NAVIGATION LIGHTING SYSTEM) (Bridge A & B) | LUMP | 1 |
| 0041 | 822-09-00100 | Electrical System (MAINTAIN EXISTING NAVIGATION LIGHTING SYSTEM) (Bridge C) | LUMP | 1 |
| 0042 | 822-09-00100 | Electrical System (MAINTAIN EXISTING NAVIGATION LIGHTING SYSTEM) (Bridge D) | LUMP | 1 |
| 0043 | 822-11-00100 | Removal and Disposal of Electrical Equipment (NAVIGATION LIGHTING) (Bridge A & B) | LUMP | 1 |
| 0044 | 822-11-00100 | Removal and Disposal of Electrical Equipment (NAVIGATION LIGHTING) (Bridge C) | LUMP | 1 |
| 0045 | 822-11-00100 | Removal and Disposal of Electrical Equipment (NAVIGATION LIGHTING) (Bridge D) | LUMP | 1 |
| 0046 | 822-16-00300 | Underground Junction Box (13" x 24") | EACH | 3 |
| 0047 | 822-17-00500 | Structure Junction Box (STAINLESS STEEL)(10"X8"X4") | EACH | 92 |
| 0048 | 822-18-00100 | Service Pole | EACH | 3 |
| 0049 | 822-21-00100 | Duct Marker (Concrete) | EACH | 2 |
| 0050 | 822-22-00300 | Underground Marker Tape (6")(Detectable) | LNFT | 545 |