Line Number | Item | Description | Unit | Quantity |
| 0001 | 201-01-00100 | Clearing and Grubbing | LUMP | 1 |
| 0002 | 202-01-00100 | Removal of Structures and Obstructions | LUMP | 1 |
| 0003 | 202-02-32100 | Removal of Pipe (Cross Drain) (2) 54" EQUIV. X 40' RCPA | LNFT | 80 |
| 0004 | 202-02-32120 | Removal of Pipe (Side Drain) 18" X 30' PP | LNFT | 30 |
| 0005 | 203-05-00100 | Excavation and Embankment | LUMP | 1 |
| 0006 | 204-05-00100 | Temporary Sediment Check Dams (Hay) | EACH | 8 |
| 0007 | 204-06-00100 | Temporary Silt Fencing | LNFT | 540 |
| 0008 | 401-02-00100 | Aggregate Surface Course (Adjusted Vehicular Measurement) | CUYD | 13 |
| 0009 | 402-03-00100 | Non-Mainline Traffic Maintenance Surfacing (Aggregate) (Vehicular Measurement) | CUYD | 25 |
| 0010 | 502-01-00100 | Asphalt Concrete | TON | 55.9 |
| 0011 | 509-01-00100 | Milling Asphalt Pavement | SQYD | 562 |
| 0012 | 509-02-00100 | Contractor Retained Reclaimed Asphalt Pavement | CUYD | -23 |
| 0013 | 510-01-00260 | Pavement Patching (16 inch Minimum Thickness) | SQYD | 166 |
| 0014 | 701-05-01042 | Side Drain Pipe (18" RCP/RPVCP/CPEPDW/CMP) | LNFT | 40 |
| 0015 | 701-17-00100 | Trench Excavation Safety Protection (Depth >5 feet) | LNFT | 72 |
| 0016 | 705-01-00100 | Barbed Wire Fence | LNFT | 135 |
| 0017 | 705-04-00100 | Single Swinging Driveway Gates | EACH | 1 |
| 0018 | 708-01-00100 | Right-of-Way Monument | EACH | 8 |
| 0019 | 708-02-00100 | Right-of-Way Monument Witness Post | EACH | 8 |
| 0020 | 712-01-00100 | Concrete Cast-in-Place Revetment (4" Thick) | SQYD | 256 |
| 0021 | 713-01-00100 | Temporary Signs and Barricades | LUMP | 1 |
| 0022 | 713-03-01000 | Temporary Pavement Markings (Broken Line) (4" Width) (4' Length) | MILE | 0.042 |
| 0023 | 713-04-01000 | Temporary Pavement Markings (Solid Line) (4" Width) | MILE | 0.083 |
| 0024 | 716-01-00100 | Mulch (Vegetative) | TON | 1 |
| 0025 | 717-01-00100 | Seeding | LB | 40 |
| 0026 | 718-01-00100 | Fertilizer | LB | 500 |
| 0027 | 720-01-01000 | Erosion Control System (Slope Protection) (Type A) | SQYD | 1,103 |
| 0028 | 726-01-00100 | Bedding Material | CUYD | 93.1 |
| 0029 | 727-01-00100 | Mobilization | LUMP | 1 |
| 0030 | 729-16-00200 | Object Marker Assembly (Type 2) | EACH | 4 |
| 0031 | 731-02-00100 | Reflectorized Raised Pavement Markers | EACH | 6 |
| 0032 | 732-02-02000 | Plastic Pavement Striping (Solid Line) (4" Width) (Thermoplastic 90 mil) | MILE | 0.083 |
| 0033 | 732-03-02000 | Plastic Pavement Striping (Broken Line) (4" Width) (Thermoplastic 90 mil) | MILE | 0.042 |
| 0034 | 740-01-00100 | Construction Layout | LUMP | 1 |
| 0035 | 805-15-00300 | Reinforced Concrete Box Culverts (Precast) (6' x 4') | LNFT | 288 |
| 0036 | 805-17-00100 | Reinforced Concrete Box Culvert Headwall (731 LBS OF STEEL AND 8.6 CU. YDS. OF CONCRETE PER HEADWALL) | EACH | 2 |