Line Number | Item | Description | Unit | Quantity |
| 0001 | 202-01-00100 | Removal of Structures and Obstructions | LUMP | 1 |
| 0002 | 202-02-02000 | Removal of Asphalt Drives | SQYD | 553.5 |
| 0003 | 202-02-02020 | Removal of Asphalt Pavement | SQYD | 2,402.1 |
| 0004 | 202-02-03000 | Removal of Base – Soil Cement, Asphalt, or BCS | SQYD | 1,033.5 |
| 0005 | 202-02-03010 | Removal of Base – Recycled PCC or Stone | SQYD | 457.3 |
| 0006 | 202-02-06040 | Removal of Concrete Box Headwall 4' x 4' TRIPLE RCB | EACH | 1 |
| 0007 | 202-02-06100 | Removal of Concrete Walks and Drives | SQYD | 2,604.1 |
| 0008 | 202-02-14500 | Removal of Guard Rail | LNFT | 997 |
| 0009 | 202-02-40100 | Removal of Traffic Signal Equipment | LUMP | 1 |
| 0010 | 202-02-40120 | Removal of Traffic Detectors and Associated Equipment | LUMP | 1 |
| 0011 | 203-05-00100 | Excavation and Embankment | LUMP | 1 |
| 0012 | 204-05-00100 | Temporary Sediment Check Dams (Hay) | EACH | 36 |
| 0013 | 204-06-00100 | Temporary Silt Fencing | LNFT | 225 |
| 0014 | 302-02-16030 | Class II Base Course (16" Thick) (Asphalt Concrete Base on Embankment Layer) | SQYD | 3,887 |
| 0015 | 402-03-00100 | Non-Mainline Traffic Maintenance Surfacing (Aggregate) (Vehicular Measurement) | CUYD | 175 |
| 0016 | 502-01-00100 | Asphalt Concrete | TON | 14,443.6 |
| 0017 | 502-01-00200 | Asphalt Concrete, Drives, Turnouts and Miscellaneous | TON | 651.3 |
| 0018 | 509-01-00100 | Milling Asphalt Pavement | SQYD | 72,721 |
| 0019 | 509-02-00100 | Contractor Retained Reclaimed Asphalt Pavement | CUYD | -4,872 |
| 0020 | 510-01-00100 | Pavement Patching (6" Minimum Thickness) | SQYD | 1,093 |
| 0021 | 510-01-00250 | Pavement Patching (14 inch Minimum Thickness) | SQYD | 1,047 |
| 0022 | 701-01-01180 | Cross Drain Pipe (96" RCP) | LNFT | 30 |
| 0023 | 701-03-01092 | Storm Drain Pipe (42" RCP/RPVCP) | LNFT | 452 |
| 0024 | 701-04-01020 | Storm Drain Pipe Arch (18" Equiv. RCPA) | LNFT | 52 |
| 0025 | 701-04-01040 | Storm Drain Pipe Arch (24" Equiv. RCPA) | LNFT | 560 |
| 0026 | 701-15-00100 | Concrete Collar | EACH | 2 |
| 0027 | 701-17-00100 | Trench Excavation Safety Protection (Depth >5 feet) | LNFT | 1,136 |
| 0028 | 702-02-00100 | Manholes (MH-06) | EACH | 1 |
| 0029 | 702-02-00900 | Manholes (MH-14X Open) | EACH | 1 |
| 0030 | 702-03-00100 | Catch Basins (CB-01) | EACH | 11 |
| 0031 | 702-03-00200 | Catch Basins (CB-02) | EACH | 6 |
| 0032 | 702-08-00300 | Side Drain Safety End (Type 3) | EACH | 2 |
| 0033 | 704-01-01020 | Guard Rail (Single Thrie Beam) (6'-3" post spacing) | LNFT | 350 |
| 0034 | 704-03-00200 | Blocked Out Guard Rail - 31", (6'-3" Post Spacing) | LNFT | 306.25 |
| 0035 | 704-06-00200 | Guard Rail Bridge Attachments (Single Thrie Beam) | LNFT | 25 |
| 0036 | 704-07-00200 | Guard Rail Transitions (Double Thrie Beam) | LNFT | 150 |
| 0037 | 704-10-00205 | Guard Rail End Treatment, MASH, (TL-3 Tangent) | EACH | 5 |
| 0038 | 704-10-00310 | Guard Rail End Treatment, NCHRP 350 - 31" (TL-3 Flared) | EACH | 1 |
| 0039 | 706-02-00100 | Concrete Drive (4" Thick) | SQYD | 278.5 |
| 0040 | 706-02-00200 | Concrete Drive (6" Thick) | SQYD | 2,325.6 |
| 0041 | 707-01-00100 | Concrete Curb (Barrier) | LNFT | 431.2 |
| 0042 | 707-03-00100 | Combination Concrete Curb and Gutter (MOUNTABLE) | LNFT | 456.5 |
| 0043 | 707-04-00100 | Asphalt Curb | LNFT | 81 |
| 0044 | 708-01-00100 | Right-of-Way Monument | EACH | 5 |
| 0045 | 708-02-00100 | Right-of-Way Monument Witness Post | EACH | 5 |
| 0046 | 713-01-00100 | Temporary Signs and Barricades | LUMP | 1 |
| 0047 | 713-02-00100 | Temporary Pavement Markings (4" Width) | LNFT | 15,468 |
| 0048 | 713-02-00300 | Temporary Pavement Markings (8" Width) | LNFT | 1,720 |
| 0049 | 713-02-00500 | Temporary Pavement Markings (24" Width) | LNFT | 257 |
| 0050 | 713-03-01000 | Temporary Pavement Markings (Broken Line) (4" Width) (4' Length) | MILE | 13.407 |
| 0051 | 713-03-02000 | Temporary Pavement Markings (Broken Line) (4" Width) (10' Length) | MILE | 4.714 |
| 0052 | 713-04-01000 | Temporary Pavement Markings (Solid Line) (4" Width) | MILE | 19.48 |
| 0053 | 713-05-00200 | Temporary Pavement Legends & Symbols (Arrow - Double) | EACH | 2 |
| 0054 | 713-05-00220 | Temporary Pavement Legends & Symbols (Arrow - Left Turn) | EACH | 12 |
| 0055 | 713-05-00230 | Temporary Pavement Legends & Symbols (Arrow - Right Turn) | EACH | 3 |
| 0056 | 722-02-00100 | Project Site Laboratory (Equipped) | EACH | 1 |
| 0057 | 724-01-00100 | Rumble Strips (Centerline) | MILE | 1.194 |
| 0058 | 724-02-00100 | Rumble Strips (Shoulder/Edge) | MILE | 2.388 |
| 0059 | 726-01-00100 | Bedding Material (12" Thick) | CUYD | 297.5 |
| 0060 | 727-01-00100 | Mobilization | LUMP | 1 |
| 0061 | 728-01-01300 | Jacked or Bored Pipe (42") (42" RCP) | LNFT | 34 |
| 0062 | 729-01-00100 | Sign (Type A) | SQFT | 9.375 |
| 0063 | 729-16-00200 | Object Marker Assembly (Type 2) | EACH | 9 |
| 0064 | 729-16-00300 | Object Marker Assembly (Type 3) | EACH | 12 |
| 0065 | 731-02-00100 | Reflectorized Raised Pavement Markers | EACH | 2,042 |
| 0066 | 732-01-01000 | Plastic Pavement Striping (4" Width) (Thermoplastic 90 mil) | LNFT | 15,468 |
| 0067 | 732-01-02040 | Plastic Pavement Striping (8" Width) (Thermoplastic 125 mil) | LNFT | 1,720 |
| 0068 | 732-01-02080 | Plastic Pavement Striping (24" Width) (Thermoplastic 125 mil) | LNFT | 257 |
| 0069 | 732-02-02000 | Plastic Pavement Striping (Solid Line) (4" Width) (Thermoplastic 90 mil) | MILE | 9.74 |
| 0070 | 732-03-02000 | Plastic Pavement Striping (Broken Line) (4" Width) (Thermoplastic 90 mil) | MILE | 2.35 |
| 0071 | 732-03-02030 | Plastic Pavement Striping (Dotted Line)(8" W)(2' L)(Thermo 90 mil) | MILE | 0.354 |
| 0072 | 732-04-01040 | Plastic Pavement Legends and Symbols (Arrow - Double) | EACH | 2 |
| 0073 | 732-04-01080 | Plastic Pavement Legends and Symbols (Arrow - Left Turn) | EACH | 12 |
| 0074 | 732-04-01100 | Plastic Pavement Legends and Symbols (Arrow - Right Turn) | EACH | 3 |
| 0075 | 735-01-00100 | Mailboxes | EACH | 45 |
| 0076 | 735-02-00100 | Mailbox Supports (Single) | EACH | 45 |
| 0077 | 736-01-00100 | Trenching and Backfilling | LNFT | 95 |
| 0078 | 736-03-00100 | Jacking or Boring | LNFT | 330 |
| 0079 | 736-04-00001 | Signal Pole (Pedestal Pole) | EACH | 1 |
| 0080 | 736-04-10300 | Signal Pole (Single Mast Arm, 30ft) | EACH | 2 |
| 0081 | 736-04-24530 | Signal Pole (Dual Mast Arm, 45ft-Arm 1, 30ft-Arm 2) | EACH | 1 |
| 0082 | 736-05-30000 | Signal Heads (3 Section, 12 inch Led Lens, R, Y, G) | EACH | 8 |
| 0083 | 736-05-35000 | Signal Heads (3 Section, 12 inch Led Lens, R, RT. Y, RT. G) | EACH | 1 |
| 0084 | 736-05-41200 | Signal Heads (4 Section, 12 inch Led Lens, LT. R, LT. Y, FLT. Y, LT. G) | EACH | 1 |
| 0085 | 736-06-00100 | Signal Service | EACH | 1 |
| 0086 | 736-06-00500 | Signal Service Pedestal Disconnect | EACH | 1 |
| 0087 | 736-08-00102 | Signal Controller (980 ATC, Type 2)(Furnish & Install) | EACH | 1 |
| 0088 | 736-10-00300 | Underground Junction Box (Type F) | EACH | 6 |
| 0089 | 736-10-00400 | Underground Junction Box (Type G) | EACH | 1 |
| 0090 | 736-11-00200 | Conduit (2" HDPE, Schedule 80) | LNFT | 120 |
| 0091 | 736-11-00300 | Conduit (3" HDPE, Schedule 80) | LNFT | 345 |
| 0092 | 736-12-02014 | Conductor (2c, #14 awg) | LNFT | 320 |
| 0093 | 736-12-03006 | Conductor (3c, 6 gauge / #6 awg) | LNFT | 110 |
| 0094 | 736-12-06014 | Conductor (6c, #14 awg) | LNFT | 680 |
| 0095 | 736-12-10014 | Conductor (10c, #14 awg) | LNFT | 643 |
| 0096 | 736-15-02400 | Signal Support (Foundation, 24 inch Minimum Diameter) | EACH | 1 |
| 0097 | 736-15-03600 | Signal Support (Foundation, 36 inch Minimum Diameter) | EACH | 3 |
| 0098 | 736-21-00000 | LED Pedestrian Countdown Signal Head | EACH | 2 |
| 0099 | 736-22-00000 | Pedestrian Push Button | EACH | 2 |
| 0100 | 739-01-00100 | Hydro-Seeding | ACRE | 0.97 |
| 0101 | 740-01-00100 | Construction Layout | LUMP | 1 |
| 0102 | 740-02-00100 | Utility Oversight and Coordination | LUMP | 1 |
| 0103 | 805-16-00100 | Reinforced Concrete Box Culverts (Extension) (4' x 4') | LNFT | 66 |
| 0104 | 805-17-00100 | Reinforced Concrete Box Culvert Headwall 4' x 4' TRIPLE RCB | EACH | 1 |
| 0105 | NS-500-00340 | Saw Cutting Asphalt Concrete Pavement | INLF | 26,889 |
| 0106 | NS-600-00220 | Saw Cutting Portland Cement Concrete Pavement | INLF | 2,874 |
| 0107 | NS-702-00100 | Paved Gutter Drain | EACH | 7 |
| 0108 | NS-736-00001 | GPS | EACH | 1 |
| 0109 | NS-736-00020 | Wireless Magnetometer Vehicle Detection System (Cabinet Components) | EACH | 1 |
| 0110 | NS-736-00021 | Wireless Magnetometer Vehicle Detection System (Antennas) | EACH | 1 |
| 0111 | NS-736-00022 | Wireless Magnetometer Vehicle Detection System (Magnetometers) | EACH | 32 |
| 0112 | NS-736-00130 | TS-2 Traffic Signal Cabinet (Ground Mounted) | EACH | 1 |