Line Number | Item | Description | Unit | Quantity |
| 0001 | 201-01-00100 | Clearing and Grubbing | LUMP | 1 |
| 0002 | 202-01-00100 | Removal of Structures and Obstructions | LUMP | 1 |
| 0003 | 202-02-02000 | Removal of Asphalt Drives | SQYD | 81 |
| 0004 | 202-02-02020 | Removal of Asphalt Pavement | SQYD | 1,307.3 |
| 0005 | 202-02-03000 | Removal of Base – Soil Cement, Asphalt, or BCS | SQYD | 1,307.3 |
| 0006 | 202-02-04501 | Removal of Bridge (Station 114+29; 5.5' x 64' PEDESTRIAN BRIDGE) | LUMP | 1 |
| 0007 | 202-02-04501 | Removal of Bridge Station 114+47; 28' x 59' Concrete Precast Slab Unit Bridge | LUMP | 1 |
| 0008 | 202-02-06100 | Removal of Concrete Walks and Drives | SQYD | 637 |
| 0009 | 202-02-12000 | Removal of Fence | LNFT | 583 |
| 0010 | 203-02-00100 | Drainage Excavation | CUYD | 365 |
| 0011 | 203-05-00100 | Excavation and Embankment | LUMP | 1 |
| 0012 | 204-05-00100 | Temporary Sediment Check Dams (Hay) | EACH | 10 |
| 0013 | 204-06-00100 | Temporary Silt Fencing | LNFT | 1,950 |
| 0014 | 204-07-00100 | Temporary Stone Construction Entrance | EACH | 1 |
| 0015 | 302-01-00400 | Class II Base Course (Asphalt Concrete Base on Embankment Layer) | CUYD | 525 |
| 0016 | 304-01-00100 | Lime | TON | 23.4 |
| 0017 | 304-05-00100 | Lime Treatment (Type E) | SQYD | 1,651 |
| 0018 | 402-01-00100 | Mainline Traffic Maintenance Surfacing (Aggregate) (Vehicular Measurement) | CUYD | 350 |
| 0019 | 502-01-00100 | Asphalt Concrete | TON | 1,541.8 |
| 0020 | 502-01-00200 | Asphalt Concrete, Drives, Turnouts and Miscellaneous | TON | 144.6 |
| 0021 | 509-01-00100 | Milling Asphalt Pavement | SQYD | 2,224 |
| 0022 | 509-02-00100 | Contractor Retained Reclaimed Asphalt Pavement | CUYD | -90 |
| 0023 | 510-01-00250 | Pavement Patching (14 inch Minimum Thickness) | SQYD | 56.2 |
| 0024 | 701-02-01080 | Cross Drain Pipe Arch (48" Equiv. RCPA) | LNFT | 82 |
| 0025 | 701-03-02022 | Storm Drain Pipe (Outfall) (18" RPVCP or 24" CMP) | LNFT | 80 |
| 0026 | 701-04-01020 | Storm Drain Pipe Arch (18" Equiv. RCPA) | LNFT | 509 |
| 0027 | 701-04-01040 | Storm Drain Pipe Arch (24" Equiv. RCPA) | LNFT | 108 |
| 0028 | 701-04-02040 | Storm Drain Pipe Arch (Outfall) (24" Equiv. CMPA) | LNFT | 111 |
| 0029 | 701-06-01040 | Side Drain Pipe Arch (24" Equiv. RCPA/CMPA) | LNFT | 76 |
| 0030 | 701-07-00600 | Yard Drain Pipe (15") | LNFT | 30 |
| 0031 | 701-14-00100 | Cleaning Existing Pipes | LNFT | 161 |
| 0032 | 701-17-00100 | Trench Excavation Safety Protection (Depth >5 feet) | LNFT | 1,440 |
| 0033 | 702-02-00100 | Manholes (MH-06) | EACH | 1 |
| 0034 | 702-03-00100 | Catch Basins (CB-01) | EACH | 14 |
| 0035 | 702-07-00200 | Cross Drain Safety End (Type 2) | EACH | 1 |
| 0036 | 702-08-00100 | Side Drain Safety End (Type 1) | EACH | 1 |
| 0037 | 704-03-00100 | Blocked Out Guard rail | LNFT | 31.25 |
| 0038 | 704-03-00200 | Blocked Out Guard Rail - 31", (6'-3" Post Spacing) | LNFT | 125 |
| 0039 | 704-05-00100 | Guard Rail Anchor Sections (Trailing End) | LNFT | 6.25 |
| 0040 | 704-07-00200 | Guard Rail Transitions (Double Thrie Beam) | LNFT | 100 |
| 0041 | 704-10-00205 | Guard Rail End Treatment, MASH, (TL-3 Tangent) | EACH | 3 |
| 0042 | 705-01-00100 | Barbed Wire Fence | LNFT | 409 |
| 0043 | 705-04-00100 | Single Swinging Driveway Gates | EACH | 1 |
| 0044 | 705-05-00100 | Double Swinging Driveway Gates | DBGT | 1 |
| 0045 | 706-01-00100 | Concrete Walk (4" Thick) 5.0' SIDEWALK (RT. SIDE ONLY) | SQYD | 482.9 |
| 0046 | 706-02-00200 | Concrete Drive (6" Thick) | SQYD | 784.1 |
| 0047 | 708-01-00100 | Right-of-Way Monument | EACH | 19 |
| 0048 | 711-01-03020 | Riprap (30 lb, 18" Thick) | SQYD | 162.7 |
| 0049 | 711-04-00100 | Geotextile Fabric | SQYD | 132 |
| 0050 | 712-04-00100 | Flexible Revetment | SQYD | 459 |
| 0051 | 713-01-00100 | Temporary Signs and Barricades | LUMP | 1 |
| 0052 | 713-03-01000 | Temporary Pavement Markings (Broken Line) (4" Width) (4' Length) | MILE | 0.53 |
| 0053 | 713-04-01000 | Temporary Pavement Markings (Solid Line) (4" Width) | MILE | 2.847 |
| 0054 | 713-06-00100 | Temporary Reflectorized Raised Pavement Markers | EACH | 84 |
| 0055 | 713-11-00100 | Portable Changeable Message Signs | EACH | 1 |
| 0056 | 716-01-00100 | Mulch (Vegetative) | TON | 0.6 |
| 0057 | 717-01-00100 | Seeding | LB | 74 |
| 0058 | 718-01-00100 | Fertilizer | LB | 1,834 |
| 0059 | 720-01-01000 | Erosion Control System (Slope Protection) (Type A) | SQYD | 228 |
| 0060 | 720-01-02040 | Erosion Control System, Flexible (Channel Liner) (Type E) | SQYD | 32 |
| 0061 | 722-02-00100 | Project Site Laboratory (Equipped) | EACH | 1 |
| 0063 | 726-01-00100 | Bedding Material | CUYD | 109.9 |
| 0064 | 727-01-00100 | Mobilization | LUMP | 1 |
| 0065 | 729-16-00300 | Object Marker Assembly (Type 3) | EACH | 4 |
| 0066 | 731-02-00100 | Reflectorized Raised Pavement Markers | EACH | 46 |
| 0067 | 732-02-02000 | Plastic Pavement Striping (Solid Line) (4" Width) (Thermoplastic 90 mil) | MILE | 0.713 |
| 0068 | 732-03-02000 | Plastic Pavement Striping (Broken Line) (4" Width) (Thermoplastic 90 mil) | MILE | 0.107 |
| 0069 | 735-01-00100 | Mailboxes | EACH | 3 |
| 0070 | 735-02-00100 | Mailbox Supports (Single) | EACH | 3 |
| 0071 | 740-01-00100 | Construction Layout | LUMP | 1 |
| 0072 | 803-10-00500 | Permanent Casing (42" Diameter) | LNFT | 60 |
| 0073 | 804-01-00600 | Precast Concrete Piles (24") | LNFT | 1,665 |
| 0074 | 804-17-00100 | Construction Site Survey | LUMP | 1 |
| 0075 | 804-18-00100 | Vibration Monitoring | DAY | 10 |
| 0076 | 805-01-00100 | Class A1 Concrete (Slab Span) | CUYD | 139.79 |
| 0077 | 805-01-00300 | Class A1 Concrete (Bent Cap) | CUYD | 59.78 |
| 0078 | 805-18-00100 | Concrete Finish (Class 2 Rubbed Finish) | SQFT | 1,384 |
| 0079 | 805-18-00200 | Concrete Finish (Class 3 Special Finish) | SQFT | 1,384 |
| 0080 | 806-01-00100 | Deformed Reinforcing Steel | LB | 46,154 |
| 0081 | 810-01-00120 | Concrete Bridge Railing (36 inch Height) | LNFT | 200 |
| 0082 | 810-02-00100 | Metal Bridge Railing | LNFT | 80 |
| 0083 | 813-01-00100 | Concrete Approach Slabs (Cast-in-Place) | SQFT | 1,446 |
| 0084 | 814-01-00100 | Elastomeric Bearing Pads (Non-Reinforced) | SFIN | 110 |
| 0085 | 815-03-00300 | Joint Seal (Poured) | LNFT | 193 |
| 0086 | NS-500-00240 | Sawing and Sealing Transverse Joints in Asphalt Concrete Overlay | LNFT | 220.08 |
| 0087 | NS-500-00260 | Sawcuts in Asphalt Concrete Lifts | LNFT | 440.16 |
| 0088 | NS-500-00340 | Saw Cutting Asphalt Concrete Pavement | INLF | 810 |
| 0089 | NS-600-00220 | Saw Cutting Portland Cement Concrete Pavement | INLF | 90 |
| 0090 | NS-700-00810 | Impact Attenuator (Construction Zone)(Test Level 3) | EACH | 4 |
| 0091 | NS-706-00100 | Truncated Dome System (Asphalt Concrete Pavement) | EACH | 2 |