Line Number | Item | Description | Unit | Quantity |
| 0001 | 201-01-00100 | Clearing and Grubbing | LUMP | 1 |
| 0002 | 202-01-00100 | Removal of Structures and Obstructions | LUMP | 1 |
| 0003 | 202-02-00010 | Removal of Billboards (Stations 1700+60, 60' Lt. and 1706+68, 55' Lt.) (Includes Removal of Supports and Footings) | EACH | 2 |
| 0004 | 202-02-00020 | Removal of Incidental Concrete Paving | SQYD | 585 |
| 0005 | 202-02-02020 | Removal of Asphalt Pavement | SQYD | 70,528.8 |
| 0006 | 202-02-03000 | Removal of Base – Soil Cement, Asphalt, or BCS | SQYD | 188,789.3 |
| 0007 | 202-02-04501 | Removal of Bridge (Str. No. 03504500606681, 1,756' x 40' COPSGR) | LUMP | 1 |
| 0008 | 202-02-04501 | Removal of Bridge (Str. No. 03504500606682, 1,748' x 40' COPSGR) | LUMP | 1 |
| 0009 | 202-02-06000 | Removal of Concrete Approach Slabs | SQYD | 355.56 |
| 0010 | 202-02-12000 | Removal of Fence | LNFT | 4,142 |
| 0011 | 202-02-14500 | Removal of Guard Rail | LNFT | 2,307 |
| 0012 | 202-02-18000 | Removal of Impact Attenuator | EACH | 2 |
| 0013 | 202-02-32500 | Removal of Portland Cement Concrete Pavement | SQYD | 115,766 |
| 0014 | 202-02-38220 | Removal of Sign Supports | EACH | 34 |
| 0015 | 202-02-38300 | Removal of Sign and U-Channel Post | EACH | 12 |
| 0016 | 202-02-38360 | Removal of Sign Faces | EACH | 30 |
| 0017 | 203-01-00100 | General Excavation | CUYD | 229,754 |
| 0018 | 203-02-00100 | Drainage Excavation | CUYD | 293 |
| 0019 | 203-03-00100 | Embankment | CUYD | 64,460 |
| 0020 | 203-04-00300 | Nonplastic Embankment (Stone) | CUYD | 603 |
| 0021 | 203-08-00100 | Geotextile Fabric | SQYD | 2,548 |
| 0022 | 203-10-00100 | Cleaning Existing Ditches | LNFT | 1,004 |
| 0023 | 203-11-00100 | Settlement Plate Installation and Monitoring | EACH | 6 |
| 0024 | 204-02-00100 | Temporary Hay Bales | EACH | 140 |
| 0025 | 204-05-00100 | Temporary Sediment Check Dams (Hay) | EACH | 113 |
| 0026 | 204-06-00100 | Temporary Silt Fencing | LNFT | 52,935 |
| 0027 | 302-02-04000 | Class II Base Course (4" Thick) | SQYD | 329,560 |
| 0028 | 302-02-06000 | Class II Base Course (6" Thick) | SQYD | 1,554 |
| 0029 | 302-02-08010 | Class II Base Course (8" Thick) (Soil Cement) | SQYD | 345,253.3 |
| 0030 | 302-02-10000 | Class II Base Course (10" Thick) | SQYD | 3,009 |
| 0031 | 304-01-00100 | Lime | TON | 428.71 |
| 0032 | 304-04-00400 | Lime Treatment (Type D) (12" Thick) | SQYD | 24,566 |
| 0033 | 304-05-00100 | Lime Treatment (Type E) | SQYD | 5,678 |
| 0034 | 305-01-04020 | Subgrade Layer (12" Thick) (Treated) | SQYD | 345,253 |
| 0035 | 401-01-00100 | Aggregate Surface Course (Net Section) | CUYD | 271.2 |
| 0036 | 402-02-00100 | Mainline Traffic Maintenance Surfacing (Hard) | SQYD | 982 |
| 0037 | 402-03-00100 | Non-Mainline Traffic Maintenance Surfacing (Aggregate) (Vehicular Measurement) | CUYD | 168 |
| 0038 | 501-03-00100 | Thin Asphalt Concrete (OGFC) | TON | 24,927.8 |
| 0039 | 502-01-00100 | Asphalt Concrete | TON | 214,674 |
| 0040 | 502-01-00200 | Asphalt Concrete, Drives, Turnouts and Miscellaneous | TON | 150.8 |
| 0041 | 510-01-00200 | Pavement Patching (12" Minimum Thickness) | SQYD | 2,332 |
| 0042 | 701-01-01024 | Cross Drain Pipe (30" RCP/RPVCP) | LNFT | 16 |
| 0043 | 701-02-01000 | Cross Drain Pipe Arch (24" Equiv. RCPA) | LNFT | 280 |
| 0044 | 701-03-01022 | Storm Drain Pipe (18" RCP/RPVCP) | LNFT | 286 |
| 0045 | 701-05-01042 | Side Drain Pipe (18" RCP/RPVCP/CPEPDW/CMP) | LNFT | 138 |
| 0046 | 701-05-01061 | Side Drain Pipe (24" RCP/RPVCP/CPEPDW/CMP) | LNFT | 276 |
| 0047 | 701-06-01020 | Side Drain Pipe Arch (18" Equiv. RCPA/CMPA) | LNFT | 40 |
| 0048 | 701-06-01040 | Side Drain Pipe Arch (24" Equiv. RCPA/CMPA) | LNFT | 78 |
| 0049 | 701-15-00100 | Concrete Collar | EACH | 4 |
| 0050 | 701-17-00100 | Trench Excavation Safety Protection (Depth >5 feet) | LNFT | 708 |
| 0051 | 702-03-00100 | Catch Basins (CB-01) | EACH | 4 |
| 0052 | 702-04-00200 | Adjusting Catch Basins | EACH | 2 |
| 0053 | 702-08-00100 | Side Drain Safety End (Type 1) | EACH | 3 |
| 0054 | 702-08-00200 | Side Drain Safety End (Type 2) | EACH | 3 |
| 0055 | 704-03-00200 | Blocked Out Guard Rail - 31", (6'-3" Post Spacing) | LNFT | 1,343.8 |
| 0056 | 704-05-00300 | Guard Rail Anchor Sections - 31", (Trailing End) | LNFT | 40 |
| 0057 | 704-07-00200 | Guard Rail Transitions (Double Thrie Beam) | LNFT | 200 |
| 0058 | 704-10-00110 | Guard Rail End Treatment (Flared 18' - 9" Length) | EACH | 1 |
| 0059 | 704-10-00205 | Guard Rail End Treatment, MASH, (TL-3 Tangent) | EACH | 12 |
| 0060 | 704-10-00310 | Guard Rail End Treatment, NCHRP 350 - 31" (TL-3 Flared) | EACH | 1 |
| 0061 | 705-01-00100 | Barbed Wire Fence | LNFT | 523 |
| 0062 | 705-05-00100 | Double Swinging Driveway Gates | DBGT | 4 |
| 0063 | 705-06-00200 | Chain Link Fence (5-Foot Height) | LNFT | 4,508 |
| 0064 | 706-03-00300 | Incidental Concrete Paving (6" Thick) | SQYD | 1,887.6 |
| 0065 | 708-01-00100 | Right-of-Way Monument | EACH | 19 |
| 0066 | 708-02-00100 | Right-of-Way Monument Witness Post | EACH | 19 |
| 0067 | 711-01-05000 | Riprap (130 lb, 24" Thick) | SQYD | 16 |
| 0068 | 711-04-00100 | Geotextile Fabric | SQYD | 16 |
| 0069 | 712-01-00100 | Concrete Cast-in-Place Revetment (4" Thick) | SQYD | 2,954.08 |
| 0070 | 713-01-00100 | Temporary Signs and Barricades | LUMP | 1 |
| 0071 | 713-03-02000 | Temporary Pavement Markings (Broken Line) (4" Width) (10' Length) | MILE | 25.483 |
| 0072 | 713-04-01000 | Temporary Pavement Markings (Solid Line) (4" Width) | MILE | 50.965 |
| 0073 | 713-06-00100 | Temporary Reflectorized Raised Pavement Markers | EACH | 20,182 |
| 0074 | 713-07-00100 | Temporary Precast Concrete Barrier (Contractor Furnished) | EACH | 3,837 |
| 0075 | 713-10-00100 | Temporary Precast Concrete Barrier Movement | EACH | 4,940 |
| 0076 | 713-11-00100 | Portable Changeable Message Signs | EACH | 4 |
| 0077 | 716-01-00100 | Mulch (Vegetative) | TON | 6.41 |
| 0078 | 720-01-01000 | Erosion Control System (Slope Protection) (Type A) | SQYD | 2,369 |
| 0079 | 720-01-02000 | Erosion Control System, Flexible (Channel Liner) (Type C) | SQYD | 500 |
| 0080 | 722-02-00100 | Project Site Laboratory (Equipped) | EACH | 1 |
| 0081 | 724-02-00100 | Rumble Strips (Shoulder/Edge) | MILE | 25 |
| 0082 | 725-01-00100 | Temporary Detour Roads | SQYD | 27,236 |
| 0083 | 726-01-00100 | Bedding Material | CUYD | 258.6 |
| 0084 | 727-01-00100 | Mobilization | LUMP | 1 |
| 0085 | 728-01-00400 | Jacked or Bored Pipe (8") (Temporary Drainage) | LNFT | 324 |
| 0086 | 729-01-00100 | Sign (Type A) | SQFT | 228.7 |
| 0087 | 729-01-00103 | Sign (Type A)(Relocate) | SQFT | 7 |
| 0088 | 729-04-00100 | Sign (Type D) | SQFT | 502 |
| 0089 | 729-05-00100 | Sign (Type E) | SQFT | 110 |
| 0090 | 729-06-00100 | Sign (Overhead Mounted) | SQFT | 586.8 |
| 0091 | 729-08-00200 | Mounting (3 1/2" Size Post) | EACH | 2 |
| 0092 | 729-08-00220 | Mounting (3 1/2" Size Post)(Median Barrier Mount) | EACH | 2 |
| 0093 | 729-08-00300 | Mounting (5" Size Post) | EACH | 2 |
| 0094 | 729-08-00600 | Mounting (W6 x 12 Size Post) | EACH | 6 |
| 0095 | 729-08-00700 | Mounting (W8 x 18 Size Post) | EACH | 2 |
| 0096 | 729-08-00800 | Mounting (W8 x 24 Size Post) | EACH | 4 |
| 0097 | 729-11-00100 | Mounting (Overhead Cantilever) (Ground Mounted) | EACH | 3 |
| 0098 | 729-16-00200 | Object Marker Assembly (Type 2) | EACH | 98 |
| 0099 | 729-16-00300 | Object Marker Assembly (Type 3) | EACH | 18 |
| 0100 | 729-17-00100 | Milepost Assembly (Ground Mounted) | EACH | 8 |
| 0101 | 729-18-00100 | Milepost Assembly (Structure Mounted) | EACH | 4 |
| 0102 | 729-18-00200 | Milepost Assembly (Structure Mounted) (Secondary) | EACH | 5 |
| 0103 | 729-19-00100 | Dead End Road Installations (Type A) | EACH | 3 |
| 0104 | 729-20-00600 | Footings for Overhead Mountings (Cantilever) | EACH | 3 |
| 0105 | 729-22-00200 | Square Tubing Post with 2-1/4" Omni-Directional Anchor | EACH | 7 |
| 0106 | 731-01-00100 | Nonreflectorized Raised Pavement Markers | EACH | 13,270 |
| 0107 | 731-02-00100 | Reflectorized Raised Pavement Markers | EACH | 14,027 |
| 0108 | 732-02-02000 | Plastic Pavement Striping (Solid Line) (4" Width) (Thermoplastic 90 mil) | MILE | 26.441 |
| 0109 | 732-02-02040 | Plastic Pavement Striping (Solid Line) (8" Width) (Thermoplastic 90 mil) | MILE | 1.281 |
| 0110 | 732-02-02080 | Plastic Pavement Striping (Solid Line) (24" Width) (Thermoplastic 90 mil) | MILE | 0.339 |
| 0111 | 732-03-02000 | Plastic Pavement Striping (Broken Line) (4" Width) (Thermoplastic 90 mil) | MILE | 24.439 |
| 0112 | 732-03-02030 | Plastic Pavement Striping (Dotted Line)(8" W)(2' L)(Thermo 90 mil) | MILE | 1.28 |
| 0113 | 732-04-05040 | Plastic Pavement Legends and Symbols (EXIT ONLY) | EACH | 2 |
| 0114 | 732-05-00100 | Removal of Existing Markings | MILE | 12.566 |
| 0115 | 735-01-00100 | Mailboxes | EACH | 9 |
| 0116 | 735-02-00100 | Mailbox Supports (Single) | EACH | 9 |
| 0117 | 739-01-00100 | Hydro-Seeding | ACRE | 37.39 |
| 0118 | 740-01-00100 | Construction Layout | LUMP | 1 |
| 0119 | 740-02-00100 | Utility Oversight and Coordination | LUMP | 1 |
| 0120 | 802-03-00100 | Temporary Sheeting (Steel) | SQFT | 61,700 |
| 0121 | 804-01-00200 | Precast Concrete Piles (14") | LNFT | 120 |
| 0122 | 804-01-00400 | Precast Concrete Piles (18") | LNFT | 13,500 |
| 0123 | 804-05-00400 | Precast Concrete Test Piles (18") | EACH | 1 |
| 0124 | 804-09-00400 | Static Load Test (Precast Concrete Piles (18")) | EACH | 1 |
| 0125 | 804-10-00400 | Precast Concrete Indicator Piles (18") | EACH | 2 |
| 0126 | 804-14-00100 | Dynamic Monitoring Assistance | EACH | 14 |
| 0127 | 804-17-00100 | Construction Site Survey | LUMP | 1 |
| 0128 | 804-18-00100 | Vibration Monitoring | DAY | 12 |
| 0129 | 805-01-00200 | Class A1 Concrete (Deck) | CUYD | 883.55 |
| 0130 | 805-01-00300 | Class A1 Concrete (Bent Cap) | CUYD | 290.59 |
| 0131 | 805-01-00400 | Class A1 Concrete (Column) | CUYD | 125.98 |
| 0132 | 805-04-00300 | Class MASS(A1) Concrete (Footing) | CUYD | 201.22 |
| 0133 | 805-08-01300 | Precast-Prestressed Concrete Girders (Type LG-45) | LNFT | 2,052.4 |
| 0134 | 805-08-01400 | Precast-Prestressed Concrete Girder (Type LG-54) | LNFT | 2,140 |
| 0135 | 805-13-00900 | Reinforced Concrete Box Culverts (Cast-In-Place or Precast) (8' x 5') | LNFT | 224 |
| 0136 | 805-13-02700 | Reinforced Concrete Box Culverts (Cast-In-Place or Precast) (5' x 2') | LNFT | 604 |
| 0137 | 805-17-00100 | Reinforced Concrete Box Culvert Headwall (Stations 1699+50, 1703+50, 1713+82) | EACH | 6 |
| 0138 | 805-18-00100 | Concrete Finish (Class 2 Rubbed Finish) | SQFT | 252,920 |
| 0139 | 805-18-00200 | Concrete Finish (Class 3 Special Finish) | SQFT | 286,427 |
| 0140 | 806-01-00100 | Deformed Reinforcing Steel | LB | 303,731 |
| 0141 | 807-04-00100 | Structural Metalwork (Anchor Bolts in Backwall & Threaded Rods in Diaphragms) | LUMP | 1 |
| 0142 | 810-01-00120 | Concrete Bridge Railing (36 inch Height) | LNFT | 1,760 |
| 0143 | 810-05-00300 | Concrete Roadway Barrier (Double Face ) | LNFT | 24,523 |
| 0144 | 810-06-00100 | Concrete Pier Protection System (Vehicle) (see Concrete Barrier Summary Table) | LNFT | 424 |
| 0145 | 813-01-00100 | Concrete Approach Slabs (Cast-in-Place) | SQFT | 2,560 |
| 0146 | 814-02-00100 | Elastomeric Bearing Pads (Reinforced) | SFIN | 395.5 |
| 0147 | 815-02-00200 | Sealed Expansion Joint (End Dams and Preformed Silicone Seal) | LNFT | 226.6 |
| 0148 | 816-02-00100 | Bridge End Drain System (Open Drain) | EACH | 4 |
| 0149 | 822-01-00100 | Trenching and Backfilling | LNFT | 1,650 |
| 0150 | 822-02-00100 | Conduit w Conductors (PVC/HDPE) (3/4") (1#2 Bare Solid Ground) | LNFT | 70 |
| 0151 | 822-02-00400 | Conduit w Conductors (PVC/HDPE) (1-1/2") (2#4, 1#4 Bare Solid Ground) | LNFT | 1,800 |
| 0152 | 822-04-00200 | Jacked or Bored Casing (6" Dia) (PVC/HDPE) | LNFT | 130 |
| 0153 | 822-15-01900 | Relocate Light Poles (50') (Aluminum) (Twin Arm) (See Electrical Sheets: Luminaire, Pole, and Junction Box Equipment Description List) | EACH | 7 |
| 0154 | 822-16-00200 | Underground Junction Box (11" x 18") | EACH | 3 |
| 0155 | 822-16-00400 | Underground Junction Box (Installation of Boxes from H.003014) | EACH | 5 |
| 0156 | 822-21-00100 | Duct Marker (Concrete) | EACH | 1 |
| 0157 | 822-22-00300 | Underground Marker Tape (6")(Detectable) | LNFT | 1,650 |
| 0158 | 830-07-00100 | Structural Concrete Patching | SQFT | 19 |
| 0159 | NS-500-00340 | Saw Cutting Asphalt Concrete Pavement | INLF | 1,232,279 |
| 0160 | NS-509-00001 | Micro-Milling Asphaltic Pavement | SQYD | 12,486 |
| 0161 | NS-600-00220 | Saw Cutting Portland Cement Concrete Pavement | INLF | 1,960 |
| 0162 | NS-700-00260 | Temporary Queue Detection System | LUMP | 1 |
| 0163 | NS-700-00810 | Impact Attenuator (Construction Zone)(Test Level 3) | EACH | 7 |
| 0164 | NS-700-00820 | Impact Attenuator Relocation (Construction Zone) | EACH | 7 |