Line Number | Item | Description | Unit | Quantity |
| 0001 | 201-01-00100 | Clearing and Grubbing | LUMP | 1 |
| 0002 | 202-01-00100 | Removal of Structures and Obstructions | LUMP | 1 |
| 0003 | 202-02-00010 | Removal of Abandoned Sewer Pipe Crossing & Cap Existing Pipe Below Grade | EACH | 2 |
| 0004 | 202-02-00030 | Removal of 12" Sewer Force Main Offset & Bents | LNFT | 70 |
| 0005 | 202-02-00030 | Removal of 16" Waterline Offset & Bents | LNFT | 220 |
| 0006 | 202-02-00030 | Removal of 36" Waterline Offset & Bents | LNFT | 216 |
| 0007 | 202-02-04500 | Removal of Bridge (Sta. 17+65 to Sta. 18+80 WB C/L)(115'x33' Timber Pile Supported Slab Span Bridge) | SQFT | 3,795 |
| 0008 | 202-02-04500 | Removal of Bridge (Sta. 17+74.50 to Sta. 18+71.50 EB C/L)(97'x33'
Timber Pile Supported Slab Span Bridge) | SQFT | 3,201 |
| 0009 | 202-02-06000 | Removal of Concrete Approach Slabs | SQYD | 484 |
| 0010 | 202-02-06100 | Removal of Concrete Walks and Drives | SQYD | 242 |
| 0011 | 202-02-06140 | Removal of Curbs (Concrete) | LNFT | 659.3 |
| 0012 | 202-02-14500 | Removal of Guard Rail | LNFT | 156.2 |
| 0013 | 202-02-32500 | Removal of Portland Cement Concrete Pavement | SQYD | 3,911 |
| 0014 | 203-01-00100 | General Excavation | CUYD | 1,152 |
| 0015 | 203-02-00100 | Drainage Excavation | CUYD | 25,062 |
| 0016 | 203-03-00100 | Embankment | CUYD | 5,717 |
| 0017 | 203-08-00100 | Geotextile Fabric (Class C)(Box Culvert) | SQYD | 15,955 |
| 0018 | 204-02-00100 | Temporary Hay Bales | EACH | 56 |
| 0019 | 204-06-00100 | Temporary Silt Fencing | LNFT | 2,408 |
| 0020 | 302-01-00300 | Class II Base Course (Crushed Stone) | CUYD | 6,952.6 |
| 0021 | 302-02-12000 | Class II Base Course (12" Thick) (Crushed Stone or Recycled Concrete) | SQYD | 4,644.2 |
| 0022 | 402-01-00100 | Mainline Traffic Maintenance Surfacing (Aggregate) (Vehicular Measurement) | CUYD | 50 |
| 0023 | 502-01-00100 | Asphalt Concrete | TON | 2,323.9 |
| 0024 | 701-03-01002 | Storm Drain Pipe (15" RCP/RPVCP) | LNFT | 325 |
| 0025 | 701-03-02022 | Storm Drain Pipe (Outfall) (18" RPVCP or 24" CMP) | LNFT | 26 |
| 0026 | 701-10-01020 | Reinforced Concrete Pipe (Extension) (15") | LNFT | 40 |
| 0027 | 701-10-01140 | Reinforced Concrete Pipe (Extension) (48") | LNFT | 20 |
| 0028 | 701-12-01020 | Corrugated Metal Pipe (Extension) (15") | LNFT | 40 |
| 0029 | 701-12-01040 | Corrugated Metal Pipe (Extension) (18") | LNFT | 20 |
| 0030 | 701-15-00100 | Concrete Collar | EACH | 7 |
| 0031 | 701-17-00100 | Trench Excavation Safety Protection (Depth >5 feet) | LNFT | 173 |
| 0032 | 702-02-00200 | Manholes (R-CB-11) | EACH | 1 |
| 0033 | 702-03-00100 | Catch Basins (CB-01) | EACH | 6 |
| 0034 | 702-03-00500 | Catch Basins (CB-06) | EACH | 6 |
| 0035 | 702-04-00100 | Adjusting Manholes | EACH | 1 |
| 0036 | 702-04-00200 | Adjusting Catch Basins | EACH | 5 |
| 0037 | 705-06-00300 | Chain Link Fence (6-Foot Height) | LNFT | 174 |
| 0038 | 706-01-00200 | Concrete Walk (5" Thick) | SQYD | 703.9 |
| 0039 | 706-02-00200 | Concrete Drive (6" Thick) | SQYD | 113.4 |
| 0040 | 706-04-00100 | Handicapped Curb Ramps | EACH | 5 |
| 0041 | 707-03-00100 | Combination Concrete Curb and Gutter | LNFT | 3,600.4 |
| 0042 | 711-01-03040 | Riprap (30 lb, 24" Thick) | SQYD | 156 |
| 0043 | 711-04-00100 | Geotextile Fabric (Under Riprap) | SQYD | 187 |
| 0044 | 713-01-00100 | Temporary Signs and Barricades | LUMP | 1 |
| 0045 | 713-02-00100 | Temporary Pavement Markings (4" Width) | LNFT | 5,550 |
| 0046 | 713-06-00100 | Temporary Reflectorized Raised Pavement Markers | EACH | 2,121 |
| 0047 | 713-08-00100 | Temporary Precast Concrete Barrier (Department Furnished) | EACH | 110 |
| 0048 | 713-10-00100 | Temporary Precast Concrete Barrier Movement | EACH | 100 |
| 0049 | 714-01-00100 | Slab Sodding (Bermuda Grass) | SQYD | 7,700 |
| 0050 | 722-02-00100 | Project Site Laboratory (Equipped) | EACH | 1 |
| 0051 | 725-01-00100 | Temporary Detour Roads | SQYD | 1,416 |
| 0052 | 726-01-00100 | Bedding Material | CUYD | 56.7 |
| 0053 | 727-01-00100 | Mobilization | LUMP | 1 |
| 0054 | 731-02-00100 | Reflectorized Raised Pavement Markers | EACH | 31 |
| 0055 | 732-01-02080 | Plastic Pavement Striping (24" Width) (Thermoplastic 125 mil) | LNFT | 22 |
| 0056 | 732-02-02000 | Plastic Pavement Striping (Solid Line) (4" Width) (Thermoplastic 90 mil) | MILE | 0.487 |
| 0057 | 732-03-02000 | Plastic Pavement Striping (Broken Line) (4" Width) (Thermoplastic 90 mil) | MILE | 0.246 |
| 0058 | 732-03-02030 | Plastic Pavement Striping (Dotted Line)(8" W)(2' L)(Thermo 90 mil) | MILE | 0.056 |
| 0059 | 732-04-01080 | Plastic Pavement Legends and Symbols (Arrow - Left Turn) | EACH | 4 |
| 0060 | 740-01-00100 | Construction Layout | LUMP | 1 |
| 0061 | 742-01-00600 | Sanitary Sewer Pipe (12") | LNFT | 70 |
| 0062 | 802-02-00100 | Permanent Sheeting (Steel) | SQFT | 1,400 |
| 0063 | 804-02-00100 | Treated Timber Piles (Noncoastal Treatment) | LNFT | 440 |
| 0064 | 805-01-00300 | Class A1 Concrete (Bent Cap) | CUYD | 19.4 |
| 0065 | 805-01-00600 | Class A1 Concrete (Retaining Wall) | CUYD | 92 |
| 0066 | 805-01-00900 | Class A1 Concrete (Box Culvert and Apron Slab) | CUYD | 8,376 |
| 0067 | 805-15-02200 | Reinforced Concrete Box Culverts (Precast) (9' x 8') | LNFT | 528 |
| 0068 | 805-18-00200 | Concrete Finish (Class 3 Special Finish) | SQFT | 2,690 |
| 0069 | 806-01-00100 | Deformed Reinforcing Steel | LB | 1,401,286 |
| 0070 | 807-01-00200 | Structural Metalwork (Grade 50) | LUMP | 1 |
| 0071 | 810-04-00100 | Hand Railing (Along Outside Edge of Sidewalk) | LNFT | 368.6 |
| 0072 | 817-03-00100 | Cofferdams | LUMP | 1 |
| 0073 | NS-300-00060 | Geogrid | SQYD | 9,341 |
| 0074 | NS-500-00340 | Saw Cutting Asphalt Concrete Pavement | INLF | 168 |
| 0075 | NS-500-00360 | Saw Cutting Asphalt Concrete Pavement Over Portland Cement Concrete Composite Pavement | INLF | 8,717 |
| 0076 | NS-600-00220 | Saw Cutting Portland Cement Concrete Pavement | INLF | 347 |
| 0077 | NS-700-00810 | Impact Attenuator (Construction Zone)(Test Level 3) | EACH | 3 |
| 0078 | NS-700-00820 | Impact Attenuator Relocation (Construction Zone) | EACH | 3 |
| 0079 | NS-P26-74101 | Concrete to Ductile Iron Pipe Adapter (16inch) | EACH | 1 |
| 0080 | NS-P26-74102 | Concrete to Ductile Iron Pipe Adapter (36inch) | EACH | 1 |
| 0081 | NS-P26-74103 | Concrete to Ductile Iron Pipe Adapter (42inch) (x 36inch) | EACH | 1 |
| 0082 | PS-P26-81701 | Initial Installation & Final Removal of Temporary Dams | LUMP | 1 |
| 0083 | PS-P26-81702 | Temporary Dam Removal and Replacement | EACH | 40 |
| 0084 | TS-P26-11216 | Water Main (16" Ductile Iron) | LNFT | 218 |
| 0085 | TS-P26-11616 | Butterfly Valve (16") | EACH | 2 |
| 0086 | TS-P26-11636 | Butterfly Valve (36") | EACH | 1 |
| 0087 | TS-P26-15036 | Waterline (36" Ductile Iron) | LNFT | 215 |
| 0088 | TS-P26-70100 | Fittings for Waterlines (DI) | LB | 14,635 |
| 0089 | TS-P26-10206 | Gate Valve and Valve Box (6") | EACH | 1 |
| 0090 | TS-P26-10212 | Gate Valve and Valve Box (12") | EACH | 1 |
| 0091 | TS-P26-15106 | Waterline (6" PVC) [6" (152mm) PVC] (Restrained) (Jefferson Parish) | LNFT | 13 |
| 0092 | TS-P26-15112 | Waterline (12" PVC) [12" (305mm) PVC] (Restrained) (Jefferson Parish) | LNFT | 13 |
| 0093 | TS-P26-70101 | Transitional Coupling (6") | EACH | 1 |
| 0094 | TS-P26-70102 | Transitional Coupling (12") | EACH | 1 |
| 0095 | TS-P26-70103 | Removal and Disposal of Existing AC Waterline | LNFT | 190 |