Line Number | Item | Description | Unit | Quantity |
| 0001 | 202-01-00100 | Removal of Structures and Obstructions | LUMP | 1 |
| 0002 | 202-02-00030 | Removal of Median Barrier | LNFT | 384 |
| 0003 | 202-02-04510 | Removal of Bridge Deck (Hydro Demolition) Hydro Blast | SFIN | 7,565 |
| 0004 | 202-02-14500 | Removal of Guard Rail | LNFT | 227 |
| 0005 | 202-02-38220 | Removal of Sign Supports | EACH | 22 |
| 0006 | 202-02-38280 | Removal of Sign Fascia Mountings | EACH | 4 |
| 0007 | 202-02-38300 | Removal of Sign and U-Channel Post | EACH | 17 |
| 0008 | 202-02-38330 | Removal of Sign Cantilever and Footing | EACH | 5 |
| 0009 | 202-02-38360 | Removal of Sign Faces | EACH | 114 |
| 0010 | 202-02-38380 | Removal of Sign Truss and Footings | EACH | 10 |
| 0011 | 704-03-00200 | Blocked Out Guard Rail – 31”, (6’-3” Post Spacing) | LNFT | 475 |
| 0012 | 704-03-00300 | Blocked Out Guard Rail – 31”, (3’-1 ½ ” Post Spacing) | LNFT | 656.25 |
| 0013 | 704-05-00300 | Guard Rail Anchor Sections – 31”, (Trailing End) | LNFT | 59.4 |
| 0014 | 704-10-00120 | Guard Rail End Treatment, MASH, (TL-3 Flared) | EACH | 3 |
| 0015 | 704-10-00205 | Guard Rail End Treatment, MASH, (TL-3 Tangent) | EACH | 3 |
| 0016 | 706-03-00100 | Incidental Concrete Paving (4" Thick) | SQYD | 1,246 |
| 0017 | 713-01-00100 | Temporary Signs and Barricades | LUMP | 1 |
| 0018 | 713-08-00100 | Temporary Precast Concrete Barrier (Department Furnished) | EACH | 100 |
| 0019 | 727-01-00100 | Mobilization | LUMP | 1 |
| 0020 | 729-01-00102 | Sign (Type A)(Furnish and Install) | SQFT | 728.9 |
| 0021 | 729-02-00102 | Sign (Type B)(Furnish and Install) | SQFT | 64.2 |
| 0022 | 729-04-00102 | Sign (Type D)(Furnish and Install) | SQFT | 557.5 |
| 0023 | 729-05-00102 | Sign (Type E)(Furnish and Install) | SQFT | 302 |
| 0024 | 729-06-00102 | Sign (Overhead Mounted)(Furnish and Install) | SQFT | 5,502.5 |
| 0025 | 729-08-00100 | Mounting (2 1/2" Size Post) | EACH | 5 |
| 0026 | 729-08-00200 | Mounting (3 1/2" Size Post) | EACH | 7 |
| 0027 | 729-08-00300 | Mounting (5" Size Post) | EACH | 2 |
| 0028 | 729-08-00310 | Mounting (5" Size Post)(Structure Mount) | EACH | 33 |
| 0029 | 729-08-00410 | Mounting (6" Size Post)(Structure Mount) | EACH | 2 |
| 0030 | 729-08-00610 | Mounting (W6 x 12 Size Post)(Structure Mount) | EACH | 6 |
| 0031 | 729-08-00700 | Mounting (W8 x 18 Size Post) | EACH | 4 |
| 0032 | 729-08-00800 | Mounting (W8 x 24 Size Post) | EACH | 1 |
| 0033 | 729-09-00100 | Mounting (Overhead Truss) (Ground Mounted) (60' Span) | EACH | 4 |
| 0034 | 729-09-00600 | Mounting (Overhead Truss) (Ground Mounted) (90' Span) | EACH | 1 |
| 0035 | 729-10-00100 | Mounting (Overhead Truss) (Structure Mounted) (60' Span) | EACH | 5 |
| 0036 | 729-10-00200 | Mounting (Overhead Truss) (Structure Mounted) (66' Span) | EACH | 1 |
| 0037 | 729-10-00400 | Mounting (Overhead Truss) (Structure Mounted) (78' Span) | EACH | 1 |
| 0038 | 729-10-00600 | Mounting (Overhead Truss) (Structure Mounted) (90' Span) | EACH | 1 |
| 0039 | 729-12-00100 | Mounting (Overhead Cantilever) (Structure Mounted) | EACH | 5 |
| 0040 | 729-13-00100 | Mounting (Bridge Fascia Mounted) | EACH | 3 |
| 0041 | 729-16-00300 | Object Marker Assembly (Type 3) | EACH | 10 |
| 0042 | 729-18-00100 | Milepost Assembly (Structure Mounted) | EACH | 1 |
| 0043 | 729-18-00200 | Milepost Assembly (Structure Mounted) (Secondary) | EACH | 1 |
| 0044 | 729-20-00700 | Footings for Overhead Mountings (Truss) | EACH | 9 |
| 0045 | 729-22-00200 | Square Tubing Post with 2-1/4" Omni-Directional Anchor | EACH | 3 |
| 0046 | 740-01-00100 | Construction Layout | LUMP | 1 |
| 0047 | 805-01-00900 | Class A1 Concrete (Bridge deck) | CUYD | 141.5 |
| 0048 | 806-01-00100 | Deformed Reinforcing Steel | LB | 28,324 |
| 0049 | 807-04-00100 | Structural Metalwork (AASHTO M270, GRADE 50) | LUMP | 1 |
| 0050 | 810-01-00100 | Concrete Bridge Railing (Standard) | LNFT | 246 |
| 0051 | NS-700-00800 | Impact Attenuator (Construction Zone)(Test Level 2) | EACH | 25 |
| 0052 | NS-700-00820 | Impact Attenuator Relocation (Construction Zone) | EACH | 2 |
| 0053 | NS-713-00009 | Portable Changeable Message Sign (with communications) | EACH | 8 |
| 0054 | NS-729-00009 | Bridge-Mounted Sign Struct Found Retrofit (Steel) Sign Truss | EACH | 16 |
| 0055 | NS-729-00010 | Bridge-Mounted Sign Struct Found Retrofit (Steel) Sign Cant | EACH | 5 |
| 0056 | NS-729-00031 | Breakaway Square Tubing Sign Support - Hard Concrete | EACH | 2 |