Line Number | Item | Description | Unit | Quantity |
| 0001 | 713-01-00100 | Temporary Signs and Barricades | LUMP | 1 |
| 0002 | 727-01-00100 | Mobilization | LUMP | 1 |
| 0003 | 740-01-00100 | Construction Layout | LUMP | 1 |
| 0004 | 822-01-00100 | Trenching and Backfilling | LNFT | 11,765 |
| 0005 | 822-02-00200 | Conduit w Conductors (PVC/HDPE) (1") (Conduit "Z", 1 #4 Bare Solid Ground) | LNFT | 20 |
| 0006 | 822-02-00300 | Conduit w Conductors (PVC/HDPE) (1-1/4") (Conduit "F", 4 #6, 1 #6 Bare Stranded Ground) | LNFT | 625 |
| 0007 | 822-02-00300 | Conduit w Conductors (PVC/HDPE) (1-1/4") (Conduit "G", 2 #6, 1 #6 Bare Stranded Ground) | LNFT | 8,985 |
| 0008 | 822-02-00400 | Conduit w Conductors (PVC/HDPE) (1-1/2") (Conduit "I", 2 #6, 2 #2, 1 #2 Bare Stranded Ground) | LNFT | 2,910 |
| 0009 | 822-02-00400 | Conduit w Conductors (PVC/HDPE) (1-1/2") (Conduit "J", 2 #2, 1 #2 Bare Stranded Ground) | LNFT | 235 |
| 0010 | 822-02-00500 | Conduit w Conductors (PVC/HDPE) (2") (Conduit "E", 4 #6, 4 #2, 1 #2 Bare Stranded Ground) | LNFT | 40 |
| 0011 | 822-02-00500 | Conduit w Conductors (PVC/HDPE) (2") (Conduit "H", 2 #6, 4 #2, 1 #2 Bare Stranded Ground) | LNFT | 385 |
| 0012 | 822-02-00500 | Conduit w Conductors (PVC/HDPE) (2") (Conduit "K", 4 #6, 2 #2, 1 #2 Bare Stranded Ground) | LNFT | 100 |
| 0013 | 822-02-00700 | Conduit w Conductors (PVC/HDPE) (3") (Conduit "B", 3#3/0) | LNFT | 280 |
| 0014 | 822-02-00700 | Conduit w Conductors (PVC/HDPE) (3") (Conduit "M", Spare) | LNFT | 20 |
| 0015 | 822-02-01500 | Conduit w Conductors (Rigid Alum) (2") (Conduit "W", 4 #6, 2 #2, 1 #2 Bare Stranded Ground) | LNFT | 5 |
| 0016 | 822-02-01500 | Conduit w Conductors (Rigid Alum) (2") (Conduit "X", 4 #6, 4 #2, 1 #2 Bare Stranded Ground) | LNFT | 5 |
| 0017 | 822-02-01700 | Conduit w Conductors (Rigid Alum) (3") (Conduit "C", 2 #3/0, 1#6 White Insulated Neutral, 1 #2 Green Insulated Ground) | LNFT | 10 |
| 0018 | 822-02-01700 | Conduit w Conductors (Rigid Alum) (3") (Conduit "Y", 3#3/0) | LNFT | 60 |
| 0019 | 822-02-04500 | Conduit w Conductors (Fiberglass) (2") (Conduit "D", 4 #6, 4 #2, 1 #2 Bare Stranded Ground) | LNFT | 5 |
| 0020 | 822-02-04500 | Conduit w Conductors (Fiberglass) (2") (Conduit "L", 4 #6, 2 #2, 1 #2 Bare Stranded Ground) | LNFT | 5 |
| 0021 | 822-02-04700 | Conduit w Conductors (Fiberglass) (3") (Conduit "A", 3#3/0) | LNFT | 20 |
| 0022 | 822-02-04700 | Conduit w Conductors (Fiberglass) (3") (Conduit "N", Spare) | LNFT | 20 |
| 0023 | 822-04-00200 | Jacked or Bored Casing (6" Dia) (PVC/HDPE) | LNFT | 835 |
| 0024 | 822-05-00700 | Light Pole (40') (Alum) (Single Arm) (4' Arm) | EACH | 56 |
| 0025 | 822-05-00700 | Light Pole (40') (Alum) (Single Arm) (8' Arm) | EACH | 21 |
| 0026 | 822-07-01600 | Luminaire (250 Watt) (High Pressure Sodium) | EACH | 77 |
| 0027 | 822-08-00200 | Electrical Service Point (Structure) | EACH | 2 |
| 0028 | 822-11-00100 | Removal and Disposal of Electrical Equipment | LUMP | 1 |
| 0029 | 822-12-00100 | Removal and Storage of Light Pole (Ground Mount) (40', No Arm with Internal Lowering Device; See Plan Sheet #8 "Item #1" under "REQUIRED REMOVAL WORK") | EACH | 23 |
| 0030 | 822-13-00100 | Removal and Disposal of Light Pole Foundation (Lowmast) | EACH | 23 |
| 0031 | 822-14-00100 | Removal and Disposal of Luminaire (See Plan Sheet #8 "Item #1" under "REQUIRED REMOVAL WORK") | EACH | 23 |
| 0032 | 822-16-00100 | Underground Junction Box (12" x 12") | EACH | 66 |
| 0033 | 822-16-00200 | Underground Junction Box (11" x 18") | EACH | 11 |
| 0034 | 822-16-00300 | Underground Junction Box (13" x 24") | EACH | 16 |
| 0035 | 822-19-00100 | Modular Breakaway Cable System | EACH | 77 |
| 0036 | 822-20-00100 | Disconnect (Service) (Stainless Steel, Non-Fused, 3 Pole, 200 Amp, 600 Volt) | EACH | 2 |
| 0037 | 822-21-00100 | Duct Marker (Concrete) | EACH | 30 |
| 0038 | 822-22-00300 | Underground Marker Tape (6")(Detectable) | LNFT | 11,765 |