Line Number | Item | Description | Unit | Quantity |
| 0001 | 202-01-00100 | Removal of Structures and Obstructions | LUMP | 1 |
| 0002 | 202-02-06080 | Removal of Concrete Combination Curb and Gutter | LNFT | 3,341 |
| 0003 | 202-02-14500 | Removal of Guard Rail | LNFT | 300 |
| 0004 | 202-03-38000 | Relocation of Sign Relocation of signs (including concrete base) shall be relocated according to the required elevation. | EACH | 54 |
| 0005 | 203-03-00100 | Embankment | CUYD | 6,841.6 |
| 0006 | 204-02-00100 | Temporary Hay or Straw Bales | EACH | 48 |
| 0007 | 204-06-00100 | Temporary Silt Fencing | LNFT | 20,880 |
| 0008 | 702-04-00200 | Adjusting Catch Basins | EACH | 6 |
| 0009 | 704-01-02000 | Guard Rail (DoubleThrie Beam) (3'-1 1/2" post spacing) | LNFT | 150 |
| 0010 | 704-03-00100 | Blocked Out Guard Rail | LNFT | 237.5 |
| 0011 | 704-06-00100 | Guard Rail Anchor Sections (Trailing End) | LNFT | 12.5 |
| 0012 | 704-06-00200 | Guard Rail Anchor Sections (Trailing End) (Single Thrie Beam) | LNFT | 12.5 |
| 0013 | 704-11-00100 | Guard Rail End Treatment (Flared) | EACH | 4 |
| 0014 | 707-03-00100 | Combination Concrete Curb and Gutter | LNFT | 3,341 |
| 0015 | 707-04-00100 | Asphaltic Curb | LNFT | 54 |
| 0016 | 713-01-00100 | Temporary Signs and Barricades | LUMP | 1 |
| 0017 | 713-03-02000 | Temporary Pavement Markings (Broken Line) (4" Width) (10' Length) | MILE | 1.3 |
| 0018 | 713-04-01000 | Temporary Pavement Markings (Solid Line) (4" Width) | MILE | 21.4 |
| 0019 | 717-01-00100 | Seeding | LB | 146.7 |
| 0020 | 718-01-00100 | Fertilizer | LB | 4,890 |
| 0021 | 720-01-01000 | Erosion Control System (Slope Protection) (Type A) | SQYD | 23,667.3 |
| 0022 | 727-01-00100 | Mobilization | LUMP | 1 |
| 0023 | 730-01-00100 | Trenching and Backfilling | LNFT | 8,140 |
| 0024 | 730-02-01060 | Conduit with Conductors (PVC/HDPE) (1 1/4") S40 2#6, 1#6 Bare Stranded (Conduit G) | LNFT | 4,663 |
| 0025 | 730-02-01080 | Conduit with Conductors (PVC/HDPE) (1 1/2") S40 2#2, 1#2 Bare Stranded(Conduit E) | LNFT | 4,163 |
| 0026 | 730-02-01080 | Conduit with Conductors (PVC/HDPE) (1 1/2") S40 4#6, 1#6 Bare Stranded (Conduit M) | LNFT | 134 |
| 0027 | 730-02-01100 | Conduit with Conductors (PVC/HDPE) (2") S40 Conduit L (4#2, 1#2 Bare Stranded) | LNFT | 35 |
| 0028 | 730-03-01060 | Conductors in Existing Conduit (PVC/HDPE) (1 1/4") (2#6, 1#6 Bare Stranded) | LNFT | 347 |
| 0029 | 730-03-01080 | Conductors in Existing Conduit (PVC/HDPE) (1 1/2") (2#2, 1#2 Bare Stranded) | LNFT | 199 |
| 0030 | 730-03-01080 | Conductors in Existing Conduit (PVC/HDPE) (1 1/2") (4#6, 1#6 Bare Stranded) | LNFT | 11 |
| 0031 | 730-03-01100 | Conductors in Existing Conduit (PVC/HDPE) (2") (4#2, 1#2 Bare Stranded ) | LNFT | 11 |
| 0032 | 730-03-03060 | Conductors in Existing Conduit (Ridgid Galvanized Steel) (1 1/4") (2#6, 1#6 Bare Stranded) | LNFT | 16 |
| 0033 | 730-03-03080 | Conductors in Existing Conduit (Ridgid Galvanized Steel) (1 1/2") (4#6, 1#6 Bare Stranded) | LNFT | 5 |
| 0034 | 730-03-03100 | Conductors in Existing Conduit (Ridgid Galvanized Steel) (2") (4#2, 1#2 Bare Stranded ) | LNFT | 5 |
| 0035 | 730-04-00200 | Jacked or Bored Casing (6" Diameter) (PVC/HDPE) | LNFT | 220 |
| 0036 | 730-07-05000 | Luminaire (250 Watt) (High PressureSodium) | EACH | 28 |
| 0037 | 730-07-06000 | Luminaire (400 Watt) (High PressureSodium) | EACH | 8 |
| 0038 | 730-11-00100 | Removal and Disposal of Electrical Equipment | LUMP | 1 |
| 0039 | 730-14-00100 | Removal and Disposal of Luminaires | EACH | 36 |
| 0040 | 730-15-12100 | Relocate Light Poles (40') (Aluminum) (Single Arm) | EACH | 28 |
| 0041 | 730-15-22200 | Relocate Light Poles (50') (Aluminum) (Twin Arm) | EACH | 4 |
| 0042 | 730-16-00100 | Underground Junction Box (12" x 12") | EACH | 32 |
| 0043 | 730-16-00200 | Underground Junction Box (11" x 18") | EACH | 4 |
| 0044 | 730-16-00300 | Underground Junction Box (13" x 24") | EACH | 5 |
| 0045 | 730-19-00010 | Modular Breakaway Cable System | EACH | 32 |
| 0046 | 730-21-00020 | Duct Marker (Concrete) | EACH | 8 |
| 0047 | 730-22-00420 | Underground Marker Tape (6")(Detectable) | LNFT | 8,360 |
| 0048 | 731-02-00100 | Reflectorized Raised Pavement Markers | EACH | 854 |
| 0049 | 732-01-01080 | Plastic Pavement Striping (24" Width) (Thermoplastic 90 mil) | LNFT | 260 |
| 0050 | 732-02-02000 | Plastic Pavement Striping (Solid Line) (4" Width) (Thermoplastic 90 mil) | MILE | 3.91 |
| 0051 | 732-03-02000 | Plastic Pavement Striping (Broken Line) (4" Width) (Thermoplastic 90 mil) | MILE | 0.16 |
| 0052 | 732-05-00100 | Removal of Existing Markings | MILE | 0.05 |
| 0053 | 740-01-00100 | Construction Layout | LUMP | 1 |
| 0054 | 741-06-00100 | Relocating Fire Hydrant | EACH | 1 |
| 0055 | NS-500-00340 | Saw Cutting Asphaltic Concrete Pavement | INLF | 26,776 |
| 0056 | NS-502-01000 | Asphalt Concrete | TON | 23,990.6 |
| 0057 | NS-502-01100 | Asphalt Concrete, Drives, Turnouts and Miscellaneous | TON | 376.3 |
| 0058 | NS-509-01000 | Milling Asphalt Pavement | SQYD | 2,074 |
| 0059 | NS-509-02000 | Contractor Retained Reclaimed Asphalt Pavement | CUYD | -51.6 |
| 0060 | NS-602-00001 | Milling Concrete Pavement | SQYD | 432 |
| 0061 | NS-700-00020 | Adjusting Guard Rail | LNFT | 537.6 |
| 0062 | NS-713-00008 | Portable Changeable Message Sign | EACH | 5 |