Line Number | Item | Description | Unit | Quantity |
| 0001 | 201-01-00100 | Clearing and Grubbing | LUMP | 1 |
| 0002 | 202-01-00100 | Removal of Structures and Obstructions | LUMP | 1 |
| 0003 | 202-02-00030 | Removal of Existing Markings | LNFT | 100 |
| 0004 | 202-02-06100 | Removal of Concrete Walks and Drives | SQYD | 5,622 |
| 0005 | 202-02-06140 | Removal of Curbs (Concrete) | LNFT | 560 |
| 0006 | 202-03-38000 | Relocation of Sign (U-CHANNEL STREET SIGN) | EACH | 1 |
| 0007 | 203-07-00100 | Borrow (Vehicular Measurement) | CUYD | 40 |
| 0008 | 203-07-00100 | Borrow (Vehicular Measurement) (SELECT SOILS) | CUYD | 40 |
| 0009 | 204-02-00100 | Temporary Hay Bales | EACH | 100 |
| 0010 | 204-06-00100 | Temporary Silt Fencing | LNFT | 240 |
| 0011 | 302-02-04070 | Class II Base Course (4" Thick) (Crushed Stone or Recycled Portland Cement Concrete) | SQYD | 146.2 |
| 0012 | 402-01-00101 | Traffic Maintenance Surfacing (Aggregate) (Vehicular Measurement) | CUYD | 20 |
| 0013 | 602-03-00100 | Cleaning and Sealing Random Cracks | LNFT | 4,800 |
| 0014 | 702-04-00100 | Adjusting Manholes | EACH | 6 |
| 0015 | 706-01-00100 | Concrete Walk (4" Thick) | SQYD | 4,113.5 |
| 0016 | 706-02-00200 | Concrete Drive (6" Thick) | SQYD | 1,981.5 |
| 0017 | 706-04-00110 | Curb Ramps (CUSTOM) | SQYD | 13.2 |
| 0018 | 706-04-00110 | Curb Ramps (TYPE 1) | SQYD | 166.4 |
| 0019 | 706-04-00110 | Curb Ramps (TYPE 2) | SQYD | 20.8 |
| 0020 | 706-04-00110 | Curb Ramps (TYPE 3) | SQYD | 194.4 |
| 0021 | 706-04-00110 | Curb Ramps (TYPE 7) | SQYD | 226.1 |
| 0022 | 706-04-00110 | Curb Ramps (TYPE 8) | SQYD | 46.5 |
| 0023 | 707-01-00100 | Concrete Curb | LNFT | 609 |
| 0024 | 713-01-00100 | Temporary Signs and Barricades | LUMP | 1 |
| 0025 | 714-01-00600 | Slab Sodding (St. Augustine) | SQYD | 12 |
| 0026 | 716-01-00100 | Mulch (Vegetative) | TON | 2 |
| 0027 | 717-01-00100 | Seeding | LB | 1,000 |
| 0028 | 718-01-00100 | Fertilizer | LB | 1,000 |
| 0029 | 727-01-00100 | Mobilization | LUMP | 1 |
| 0030 | 729-01-00102 | Sign (Type A)(Furnish and Install) | SQFT | 40.5 |
| 0031 | 729-21-00100 | U-Channel Post | EACH | 4 |
| 0032 | 732-01-02040 | Plastic Pavement Striping (8" Width) (Thermoplastic 125 mil) | LNFT | 80 |
| 0033 | 732-01-02080 | Plastic Pavement Striping (24" Width) (Thermoplastic 125 mil) | LNFT | 40 |
| 0034 | 736-04-00001 | Signal Pole (Pedestal Pole) | EACH | 3 |
| 0035 | 736-10-00300 | Underground Junction Box (Type F) | EACH | 3 |
| 0036 | 736-11-00200 | Conduit (2" HDPE, Schedule 80) | LNFT | 120 |
| 0037 | 736-11-00300 | Conduit (3" HDPE, Schedule 80) | LNFT | 360 |
| 0038 | 736-12-02014 | Conductor (2c, #14 awg) | LNFT | 360 |
| 0039 | 736-12-06014 | Conductor (6c, #14 awg) | LNFT | 840 |
| 0040 | 736-21-00000 | LED Pedestrian Countdown Signal Head | EACH | 12 |
| 0041 | 736-22-00000 | Pedestrian Push Button | EACH | 4 |
| 0042 | 740-01-00100 | Construction Layout | LUMP | 1 |
| 0043 | 741-35-00100 | Adjust Valve or Meter Box | EACH | 19 |
| 0044 | NS-700-00100 | Trench Drains | EACH | 2 |
| 0045 | NS-719-00001 | Tree Protection Fencing | LUMP | 1 |
| 0046 | NS-719-00002 | Tree Trimming | LUMP | 1 |
| 0047 | NS-719-00003 | Root Pruning | LUMP | 1 |
| 0048 | NS-719-00004 | Hand Formed and Poured In-Place Concrete Curb Within the Limits of the Tree Dripline | LNFT | 30 |
| 0049 | NS-719-00005 | Gravel Bed and Filter Cloth over Tree Roots | SQYD | 50 |
| 0050 | NS-MSC-00080 | Detectable Warning Surface Retrofit for Curb Ramps | EACH | 7 |
| 0051 | TS-742-37000 | Adjusting Sanitary Sewer Cleanout | EACH | 56 |
| 0052 | TS-822-00993 | Horizontal Directional Drilling for Conduit | LNFT | 5,830 |
| 0053 | TS-822-01004 | Panelboard - 1 Phase - 120/240V 100A Frame - 42 Circuits | EACH | 3 |
| 0054 | TS-822-01008 | Receptacles | EACH | 200 |
| 0055 | TS-822-01013 | Surge Counter | EACH | 3 |
| 0056 | TS-822-01024 | Control System Hardware | LUMP | 1 |
| 0057 | TS-822-01058 | Stainless Steel Cabinets for Mounting Electrical Equipment | EACH | 3 |
| 0058 | TS-822-09100 | Electrical System (FOR PEDESTRIAN LIGHTING) | LUMP | 1 |
| 0059 | TS-822-09101 | Grounding and Bonding | LUMP | 1 |
| 0060 | TS-822-09117 | Conduit w Conductors (PVC/HDPE)(1")(2 #10 + 2 #8 AWG THWN COPPER CONDUCTORS + 1 #10 AWG THWN COPPER GROUND) | LNFT | 1,100 |
| 0061 | TS-822-09117 | Conduit w Conductors (PVC/HDPE)(1")(4 #10 AWG THWN COPPER CONDUCTORS + 1 #10 AWG THWN COPPER GROUND) | LNFT | 11,705 |
| 0062 | TS-822-09117 | Conduit w Conductors (PVC/HDPE)(1")(4 #8 AWG THWN COPPER CONDUCTORS + 1 #10 AWG THWN COPPER GROUND) | LNFT | 960 |
| 0063 | TS-822-09117 | Conduit w Conductors (PVC/HDPE)(2")(SECONDARY SERVICE CONDUIT RISERS) | LNFT | 4 |
| 0064 | TS-822-09117 | Conduit w Conductors (RGS)(1")(2 #8 + 2 #10 AWG THWN COPPER CONDUCTORS + 1 #10 AWG COPPER GROUND) | LNFT | 44 |
| 0065 | TS-822-09117 | Conduit w Conductors (RGS)(1")(4 #10 AWG THWN COPPER CONDUCTORS + 1 #10 AWG COPPER GROUND) | LNFT | 381 |
| 0066 | TS-822-09117 | Conduit w Conductors (RGS)(1")(4 #8 AWG THWN COPPER CONDUCTORS + 1 #10 AWG COPPER GROUND) | LNFT | 50 |
| 0067 | TS-822-09117 | Conduit w Conductors (RGS)(2")(FOR SERVICE CONDUCTORS BY ENTERGY) | LNFT | 30 |
| 0068 | TS-822-09134 | Light Pole (12 FT) (ALUM) (SINGLE ARM) (5" DIA) (FLUTED) | EACH | 60 |
| 0069 | TS-822-09134 | Light Pole (12 FT) (ALUM) (SINGLE ARM) (SMOOTH) (4" DIA) | EACH | 137 |
| 0070 | TS-822-09158 | Luminaire (LED) (IES TYPE "V" DIST) (88 WATT) | EACH | 195 |
| 0071 | TS-822-09158 | Luminaire (LED) (IES TYPE "V" DIST) (88 WATT) (INT. HOUSE SIDE SHIELDING) | EACH | 2 |
| 0072 | TS-822-09160 | Electrical Service Point (STRUCTURE) | EACH | 3 |
| 0073 | TS-MSC-40100 | Metal Plate Over Gutter | LNFT | 56 |