Line Number | Item | Description | Unit | Quantity |
0001 | 202-02-02020 | Removal of Asphalt Pavement | SQYD | 2,544.2 |
0002 | 202-02-03000 | Removal of Base – Soil Cement, Asphalt, or BCS | SQYD | 13,950.2 |
0003 | 202-02-06060 | Removal of Concrete Catch Basin | EACH | 4 |
0004 | 202-02-06100 | Removal of Concrete Walks and Drives | SQYD | 846 |
0005 | 202-02-14500 | Removal of Guard Rail | LNFT | 808 |
0006 | 202-02-32120 | Removal of Pipe (Side Drain) 15" - 18" | LNFT | 169 |
0007 | 202-02-32120 | Removal of Pipe (Side Drain) 18" - 24" | LNFT | 233 |
0008 | 202-02-32140 | Removal of Pipe (Storm Drain) 18" | LNFT | 93 |
0009 | 202-02-40100 | Removal of Traffic Signal Equipment | LUMP | 1 |
0010 | 202-02-40120 | Removal of Traffic Detectors and Associated Equipment | LUMP | 1 |
0011 | 203-05-00100 | Excavation and Embankment | LUMP | 1 |
0012 | 204-02-00100 | Temporary Hay Bales | EACH | 80 |
0013 | 204-05-00100 | Temporary Sediment Check Dams (Hay) | EACH | 12 |
0014 | 204-06-00100 | Temporary Silt Fencing | LNFT | 13,040 |
0015 | 303-01-00200 | In-Place Cement Stabilized Base Course (8-1/2" Thick) | SQYD | 12,302 |
0016 | 402-03-00100 | Non-Mainline Traffic Maintenance Surfacing (Aggregate) (Vehicular Measurement) | CUYD | 680 |
0017 | 502-01-00100 | Asphalt Concrete | TON | 15,556.8 |
0018 | 502-01-00200 | Asphalt Concrete, Drives, Turnouts and Miscellaneous | TON | 1,134.7 |
0019 | 507-01-00100 | Asphalt Material (CRS-2P Emulsion) | GAL | 17,526 |
0020 | 507-02-00200 | Aggregate (S2) | SQYD | 25,773 |
0021 | 507-02-00300 | Aggregate (S3) | SQYD | 25,773 |
0022 | 509-01-00100 | Milling Asphalt Pavement | SQYD | 101,533 |
0023 | 509-02-00100 | Contractor Retained Reclaimed Asphalt Pavement | CUYD | -4,967 |
0024 | 510-01-00300 | Pavement Patching (18" Minimum Thickness) | SQYD | 650 |
0025 | 601-02-01300 | Portland Cement Concrete Pavement (11" Thick) (Crossovers & Turnouts) | SQYD | 228.2 |
0026 | 701-03-01002 | Storm Drain Pipe (15" RCP/RPVCP) | LNFT | 62 |
0027 | 701-03-01022 | Storm Drain Pipe (18" RCP/RPVCP) | LNFT | 167 |
0028 | 701-03-01062 | Storm Drain Pipe (30" RCP/RPVCP) | LNFT | 90 |
0029 | 701-03-01082 | Storm Drain Pipe (36" RCP/RPVCP) | LNFT | 104 |
0030 | 701-03-01092 | Storm Drain Pipe (42" RCP/RPVCP) | LNFT | 22 |
0031 | 701-05-01082 | Side Drain Pipe (30" RCP/RPVCP/CMP) | LNFT | 102 |
0032 | 701-05-01102 | Side Drain Pipe (36" RCP/RPVCP/CMP) | LNFT | 60 |
0033 | 701-05-02102 | Side Drain Pipe (Erosion) (36" RPVCP/CMP) | LNFT | 80 |
0034 | 701-15-00100 | Concrete Collar | EACH | 5 |
0035 | 701-17-00100 | Trench Excavation Safety Protection (Depth >5 feet) | LNFT | 458 |
0036 | 702-02-00100 | Manholes (MH-06) | EACH | 1 |
0037 | 702-03-00100 | Catch Basins (CB-01) | EACH | 7 |
0038 | 702-03-00200 | Catch Basins (CB-02) | EACH | 1 |
0039 | 702-03-00500 | Catch Basins (CB-06) | EACH | 5 |
0040 | 702-04-00150 | Adjusting Manholes w/Manhole Adjustment Rings | EACH | 5 |
0041 | 702-04-00200 | Adjusting Catch Basins | EACH | 2 |
0042 | 702-04-00210 | Convert Catch Basins to Manholes | EACH | 1 |
0043 | 704-01-01020 | Guard Rail (Single Thrie Beam) (6'-3" post spacing) | LNFT | 312.5 |
0044 | 704-03-00200 | Blocked Out Guard Rail - 31", (6'-3" Post Spacing) | LNFT | 187.5 |
0045 | 704-07-00200 | Guard Rail Transitions (Double Thrie Beam) | LNFT | 175 |
0046 | 704-10-00310 | Guard Rail End Treatment, NCHRP 350 - 31" (TL-3 Flared) | EACH | 7 |
0047 | 706-01-00100 | Concrete Walk (4" Thick) | SQYD | 3 |
0048 | 706-02-00200 | Concrete Drive (6" Thick) | SQYD | 1,528.8 |
0049 | 706-04-00100 | Handicapped Curb Ramps | EACH | 1 |
0050 | 707-01-00200 | Concrete Curb (Barrier) | LNFT | 269.8 |
0051 | 707-03-00100 | Combination Concrete Curb and Gutter | LNFT | 629 |
0052 | 711-01-05000 | Riprap (130 lb, 24" Thick) | SQYD | 350 |
0053 | 712-02-00100 | Sacked Concrete Revetment Ditch @ State Trooper Office | SQYD | 300 |
0054 | 713-01-00100 | Temporary Signs and Barricades | LUMP | 1 |
0055 | 713-03-01000 | Temporary Pavement Markings (Broken Line) (4" Width) (4' Length) | MILE | 5.12 |
0056 | 713-03-02000 | Temporary Pavement Markings (Broken Line) (4" Width) (10' Length) | MILE | 4.362 |
0057 | 713-04-01000 | Temporary Pavement Markings (Solid Line) (4" Width) | MILE | 15.069 |
0058 | 724-01-00100 | Rumble Strips (Centerline) | MILE | 2.888 |
0059 | 724-02-00100 | Rumble Strips (Shoulder/Edge) | MILE | 8.144 |
0060 | 726-01-00100 | Bedding Material | CUYD | 81.1 |
0061 | 727-01-00100 | Mobilization | LUMP | 1 |
0062 | 729-01-00100 | Sign (Type A) | SQFT | 30 |
0063 | 731-02-00100 | Reflectorized Raised Pavement Markers | EACH | 741 |
0064 | 732-01-01000 | Plastic Pavement Striping (4" Width) (Thermoplastic 90 mil) | LNFT | 7,606 |
0065 | 732-01-01040 | Plastic Pavement Striping (8" Width) (Thermoplastic 90 mil) | LNFT | 1,053 |
0066 | 732-01-02080 | Plastic Pavement Striping (24" Width) (Thermoplastic 125 mil) | LNFT | 207 |
0067 | 732-02-02000 | Plastic Pavement Striping (Solid Line) (4" Width) (Thermoplastic 90 mil) | MILE | 16.108 |
0068 | 732-03-02000 | Plastic Pavement Striping (Broken Line) (4" Width) (Thermoplastic 90 mil) | MILE | 4.471 |
0069 | 732-03-02030 | Plastic Pavement Striping (Dotted Line)(8" W)(2' L)(Thermo 90 mil) | MILE | 0.349 |
0070 | 732-04-00001 | Plastic Pavement Legends and Symbols (Message) ONLY | EACH | 3 |
0071 | 732-04-01080 | Plastic Pavement Legends and Symbols (Arrow - Left Turn) | EACH | 14 |
0072 | 732-04-01100 | Plastic Pavement Legends and Symbols (Arrow - Right Turn) | EACH | 6 |
0073 | 736-01-00100 | Trenching and Backfilling | LNFT | 60 |
0074 | 736-03-00100 | Jacking or Boring | LNFT | 240 |
0075 | 736-04-10400 | Signal Pole (Single Mast Arm, 40ft) | EACH | 1 |
0076 | 736-05-30000 | Signal Heads (3 Section, 12 inch Led Lens, R, Y, G) | EACH | 2 |
0077 | 736-05-35001 | Signal Heads (3 Sec, 12 inch Led Lens, RT. R, RT. Y, RT. G) | EACH | 2 |
0078 | 736-05-41200 | Signal Heads (4 Section, 12 inch Led Lens, LT. R, LT. Y, FLT. Y, LT. G) | EACH | 1 |
0079 | 736-10-00300 | Underground Junction Box (Type F) | EACH | 1 |
0080 | 736-11-00300 | Conduit (3" HDPE, Schedule 80) | LNFT | 280 |
0081 | 736-12-06014 | Conductor (6c, #14 awg) | LNFT | 90 |
0082 | 736-12-10014 | Conductor (10c, #14 awg) | LNFT | 1,220 |
0083 | 736-15-03600 | Signal Support (Foundation, 36 inch Minimum Diameter) | EACH | 1 |
0084 | 740-01-00100 | Construction Layout | LUMP | 1 |
0085 | NS-500-00340 | Saw Cutting Asphalt Concrete Pavement | INLF | 23,006 |
0086 | NS-600-00220 | Saw Cutting Portland Cement Concrete Pavement | INLF | 2,324 |
0087 | NS-700-00830 | Impact Attenuator (Reusable, Test Level 2) | EACH | 1 |
0088 | NS-736-00022 | Wireless Magnetometer Vehicle Detection System (Magnetometers) | EACH | 44 |