Line Number | Item | Description | Unit | Quantity |
0001 | 201-01-00100 | Clearing and Grubbing | LUMP | 1 |
0002 | 202-01-00100 | Removal of Structures and Obstructions | LUMP | 1 |
0003 | 202-02-00030 | Removal of (CONCRETE MEDIAN BARRIER) | LNFT | 2,412 |
0004 | 202-02-02020 | Removal of Asphalt Pavement | SQYD | 130,605.7 |
0005 | 202-02-03000 | Removal of Base – Soil Cement, Asphalt, or BCS | SQYD | 166,329.9 |
0006 | 202-02-03010 | Removal of Base – Recycled PCC or Stone | SQYD | 53,018.4 |
0007 | 202-02-04501 | Removal of Bridge (STA. 184+61.63, 69.5' X 722' CONCRETE DECK GIRDER BRIDGE) | LUMP | 1 |
0008 | 202-02-04501 | Removal of Bridge (STA. 353+35.49 EB, 45.5' X 100' SLAB SPAN BRIDGE) | LUMP | 1 |
0009 | 202-02-04501 | Removal of Bridge (STA. 353+35.59 WB, 45.5' X 100' SLAB SPAN BRIDGE) | LUMP | 1 |
0010 | 202-02-04501 | Removal of Bridge (STA. 527+39.64 WB, 54.75' X 240' SLAB SPAN BRIDGE) | LUMP | 1 |
0011 | 202-02-04501 | Removal of Bridge (STA. 528+05.89 EB, 42.75' X 240' SLAB SPAN BRIDGE) | LUMP | 1 |
0012 | 202-02-04501 | Removal of Bridge (STA. 544+00.20 EB, 45.75' X 140' SLAB SPAN BRIDGE) | LUMP | 1 |
0013 | 202-02-04501 | Removal of Bridge (STA. 544+00.27 WB, 45.75' X 140' SLAB SPAN BRIDGE) | LUMP | 1 |
0014 | 202-02-04501 | Removal of Bridge (STA. 575+76.19 EB, 45.75' X 120' SLAB SPAN BRIDGE) | LUMP | 1 |
0015 | 202-02-04501 | Removal of Bridge (STA. 576+64.97 WB, 45.75' X 120' SLAB SPAN BRIDGE) | LUMP | 1 |
0016 | 202-02-06101 | Removal of Concrete Median Barrier and Footing | SQYD | 5,532 |
0017 | 202-02-14500 | Removal of Guard Rail | LNFT | 15,460.7 |
0018 | 202-02-32500 | Removal of Portland Cement Concrete Pavement | SQYD | 10,636 |
0019 | 202-02-38220 | Removal of Sign Supports | EACH | 183 |
0020 | 202-02-38300 | Removal of Sign and U-Channel Post | EACH | 32 |
0021 | 202-02-38360 | Removal of Sign Faces | EACH | 123 |
0022 | 203-01-00100 | General Excavation | CUYD | 149,907 |
0023 | 203-02-00100 | Drainage Excavation | CUYD | 6,737 |
0024 | 203-03-00100 | Embankment | CUYD | 357,869 |
0025 | 203-04-00300 | Nonplastic Embankment (Stone) | CUYD | 1,147 |
0026 | 203-08-00100 | Geotextile Fabric | SQYD | 4,009 |
0027 | 203-10-00100 | Cleaning Existing Ditches | LNFT | 5,000 |
0028 | 204-02-00100 | Temporary Hay Bales | EACH | 140 |
0029 | 204-05-00100 | Temporary Sediment Check Dams (Hay) | EACH | 664 |
0030 | 204-05-00200 | Temporary Sediment Check Dams (Stone) | EACH | 55 |
0031 | 204-06-00100 | Temporary Silt Fencing | LNFT | 164,831 |
0032 | 204-07-00100 | Temporary Stone Construction Entrance | EACH | 6 |
0033 | 302-02-04070 | Class II Base Course (4" Thick) (Crushed Stone or Recycled Portland Cement Concrete) | SQYD | 180,220.4 |
0034 | 302-02-06010 | Class II Base Course (6" Thick) (Soil Cement) | SQYD | 326,774.8 |
0035 | 302-02-10075 | Class II Base Course (10" Thick) (Crushed Stone or Recycled Portland Cement Concrete) | SQYD | 155,083.2 |
0036 | 302-02-14070 | Class II Base Course (14" Thick) (Crushed Stone or Recycled Portland Cement Concrete) | SQYD | 73,150.3 |
0037 | 302-02-16070 | Class II Base Course (16" Thick) (Crushed Stone or Recycled Portland Cement Concrete) | SQYD | 6,584.1 |
0038 | 302-02-18070 | Class II Base Course (18" Thick) (Crushed Stone or Recycled Portland Cement Concrete) | SQYD | 18,262.1 |
0039 | 305-01-04020 | Subgrade Layer (12" Thick) (Treated) | SQYD | 429,771 |
0040 | 401-02-00100 | Aggregate Surface Course (Adjusted Vehicular Measurement) | CUYD | 39 |
0041 | 402-02-00100 | Mainline Traffic Maintenance Surfacing (Hard) | SQYD | 300 |
0042 | 501-03-00100 | Thin Asphalt Concrete (OGFC) | TON | 26,110.9 |
0043 | 502-01-00100 | Asphalt Concrete | TON | 287,733.4 |
0044 | 502-01-00200 | Asphalt Concrete, Drives, Turnouts and Miscellaneous | TON | 1,147.2 |
0045 | 509-01-00100 | Milling Asphalt Pavement | SQYD | 271,419 |
0046 | 510-01-00200 | Pavement Patching (12" Minimum Thickness) | SQYD | 1,985 |
0047 | 601-01-01100 | Portland Cement Concrete Pavement (13" Thick) | SQYD | 17,571.6 |
0048 | 601-04-00100 | Portland Cement Concrete Pavement Coring | EACH | 20 |
0049 | 602-02-00200 | Cleaning and Resealing Existing Longitudinal Pavement Joints | LNFT | 1,300 |
0050 | 701-01-01003 | Cross Drain Pipe (24" RCP/RPVCP/CPEPDW) | LNFT | 128 |
0051 | 701-02-01000 | Cross Drain Pipe Arch (24" Equiv. RCPA) | LNFT | 634 |
0052 | 701-02-01060 | Cross Drain Pipe Arch (42" Equiv. RCPA) | LNFT | 400 |
0053 | 701-02-01100 | Cross Drain Pipe Arch (54" Equiv. RCPA) | LNFT | 64 |
0054 | 701-03-01002 | Storm Drain Pipe (15" RCP/RPVCP) | LNFT | 781 |
0055 | 701-03-01042 | Storm Drain Pipe (24" RCP/RPVCP) | LNFT | 565 |
0056 | 701-04-01020 | Storm Drain Pipe Arch (18" Equiv. RCPA) | LNFT | 471 |
0057 | 701-05-02061 | Side Drain Pipe (Erosion) (24" RPVCP/CPEPDW/CMP) (CMP IS NOT ALLOWED) | LNFT | 40 |
0058 | 701-10-01040 | Reinforced Concrete Pipe (Extension) (18") | LNFT | 66 |
0059 | 701-10-01060 | Reinforced Concrete Pipe (Extension) (24") | LNFT | 580 |
0060 | 701-10-01080 | Reinforced Concrete Pipe (Extension) (30") | LNFT | 154 |
0061 | 701-10-01100 | Reinforced Concrete Pipe (Extension) (36") | LNFT | 48 |
0062 | 701-11-01020 | Reinforced Concrete Pipe Arch (Extension) (18" Equiv.) | LNFT | 342 |
0063 | 701-14-00100 | Cleaning Existing Pipes | LNFT | 5,000 |
0064 | 701-15-00100 | Concrete Collar | EACH | 38 |
0065 | 702-02-00200 | Manholes (R-CB-11) | EACH | 11 |
0066 | 702-02-00900 | Manholes (MH-14X Open) | EACH | 11 |
0067 | 702-03-00100 | Catch Basins (CB-01) | EACH | 22 |
0068 | 702-03-00200 | Catch Basins (CB-02) | EACH | 1 |
0069 | 702-04-00200 | Adjusting Catch Basins | EACH | 2 |
0070 | 702-04-01000 | Capping Existing Catch Basin or Manhole | EACH | 5 |
0071 | 702-07-00100 | Cross Drain Safety End (Type 1) | EACH | 14 |
0072 | 702-07-00200 | Cross Drain Safety End (Type 2) | EACH | 2 |
0073 | 704-03-00200 | Blocked Out Guard Rail - 31", (6'-3" Post Spacing) | LNFT | 4,262.9 |
0074 | 704-03-00300 | Blocked Out Guard Rail – 31”, (3’-1 ½ ” Post Spacing) | LNFT | 206.8 |
0075 | 704-05-00300 | Guard Rail Anchor Sections - 31", (Trailing End) | LNFT | 29.7 |
0076 | 704-07-00200 | Guard Rail Transitions (Double Thrie Beam) | LNFT | 425 |
0077 | 704-10-00205 | Guard Rail End Treatment, MASH, (TL-3 Tangent) | EACH | 16 |
0078 | 704-10-00310 | Guard Rail End Treatment, NCHRP 350 - 31" (TL-3 Flared) | EACH | 11 |
0079 | 706-03-00100 | Incidental Concrete Paving (4" Thick) | SQYD | 399.4 |
0080 | 706-03-00300 | Incidental Concrete Paving (6" Thick) | SQYD | 417 |
0081 | 710-01-00100 | Flowable Fill | CUYD | 38.76 |
0082 | 711-01-04000 | Riprap (55 lb, 18" Thick) | SQYD | 125 |
0083 | 711-04-00100 | Geotextile Fabric | SQYD | 125 |
0084 | 712-04-00100 | Flexible Revetment | SQYD | 14,682 |
0085 | 713-01-00100 | Temporary Signs and Barricades | LUMP | 1 |
0086 | 713-04-01020 | Temporary Pavement Markings (Solid Line) (4"Width) (Type 1 Removable) | MILE | 311.317 |
0087 | 713-04-01020 | Temporary Pavement Markings (Solid Line) (4"Width) (Type 1 Removable) (STA. 99+12.46 - STA. 102+17.82) | MILE | 0.174 |
0088 | 713-06-00100 | Temporary Reflectorized Raised Pavement Markers | EACH | 129,361 |
0089 | 713-06-00100 | Temporary Reflectorized Raised Pavement Markers (STA. 99+12.46 - STA. 102+17.82) | EACH | 92 |
0090 | 713-07-00100 | Temporary Precast Concrete Barrier (Contractor Furnished) | EACH | 3,212 |
0091 | 713-10-00100 | Temporary Precast Concrete Barrier Movement | EACH | 13,857 |
0092 | 713-11-00100 | Portable Changeable Message Signs | EACH | 4 |
0093 | 720-01-01000 | Erosion Control System (Slope Protection) (Type A) | SQYD | 22,397 |
0094 | 720-01-02000 | Erosion Control System, Flexible (Channel Liner) (Type C) | SQYD | 1,201 |
0095 | 720-01-02020 | Erosion Control System, Flexible (Channel Liner) (Type D) | SQYD | 1,264 |
0096 | 722-02-00100 | Project Site Laboratory (Equipped) | EACH | 1 |
0097 | 724-02-00100 | Rumble Strips (Shoulder/Edge) | MILE | 37.182 |
0098 | 725-01-00100 | Temporary Detour Roads | SQYD | 12,764.2 |
0099 | 726-01-00100 | Bedding Material | CUYD | 1,101.6 |
0100 | 727-01-00100 | Mobilization | LUMP | 1 |
0101 | 729-01-00100 | Sign (Type A) | SQFT | 1,484.6 |
0102 | 729-02-00100 | Sign (Type B) | SQFT | 27 |
0103 | 729-04-00100 | Sign (Type D) | SQFT | 4,469 |
0104 | 729-04-00103 | Sign (Type D)(Relocate) | SQFT | 161.3 |
0105 | 729-05-00100 | Sign (Type E) | SQFT | 288 |
0106 | 729-06-00100 | Sign (Overhead Mounted) | SQFT | 293 |
0107 | 729-08-00100 | Mounting (2 1/2" Size Post) | EACH | 2 |
0108 | 729-08-00200 | Mounting (3 1/2" Size Post) | EACH | 35 |
0109 | 729-08-00220 | Mounting (3 1/2" Size Post)(Median Barrier Mount) | EACH | 12 |
0110 | 729-08-00300 | Mounting (5" Size Post) | EACH | 21 |
0111 | 729-08-00310 | Mounting (5" Size Post)(Structure Mount) | EACH | 1 |
0112 | 729-08-00600 | Mounting (W6 x 12 Size Post) | EACH | 62 |
0113 | 729-08-00700 | Mounting (W8 x 18 Size Post) | EACH | 32 |
0114 | 729-08-00800 | Mounting (W8 x 24 Size Post) | EACH | 14 |
0115 | 729-11-00100 | Mounting (Overhead Cantilever) (Ground Mounted) | EACH | 2 |
0116 | 729-16-00200 | Object Marker Assembly (Type 2) | EACH | 12 |
0117 | 729-16-00300 | Object Marker Assembly (Type 3) | EACH | 35 |
0118 | 729-18-00100 | Milepost Assembly (Structure Mounted) | EACH | 5 |
0119 | 729-18-00200 | Milepost Assembly (Structure Mounted) (Secondary) | EACH | 8 |
0120 | 729-20-00600 | Footings for Overhead Mountings (Cantilever) | EACH | 2 |
0121 | 731-02-00100 | Reflectorized Raised Pavement Markers | EACH | 11,720 |
0122 | 731-02-00100 | Reflectorized Raised Pavement Markers (STA. 99+12.46 - STA. 102+17.82) | EACH | 31 |
0123 | 732-01-01080 | Plastic Pavement Striping (24" Width) (Thermoplastic 90 mil) | LNFT | 1,611 |
0124 | 732-02-02000 | Plastic Pavement Striping (Solid Line) (4" Width) (Thermoplastic 90 mil) | MILE | 41.068 |
0125 | 732-02-02000 | Plastic Pavement Striping (Solid Line) (4" Width) (Thermoplastic 90 mil) (STA. 99+12.46 - STA. 102+17.82) | MILE | 0.116 |
0126 | 732-02-02040 | Plastic Pavement Striping (Solid Line) (8" Width) (Thermoplastic 90 mil) | MILE | 2.721 |
0127 | 732-03-02000 | Plastic Pavement Striping (Broken Line) (4" Width) (Thermoplastic 90 mil) | MILE | 38.652 |
0128 | 732-03-02002 | Plastic Pav't Striping (Broken) (4" Width) (Thermo 90 mil)(Black and White Cont) | MILE | 1.012 |
0129 | 732-03-02002 | Plastic Pav't Striping (Broken) (4" Width) (Thermo 90 mil)(Black and White Cont) (STA. 99+12.46 - STA. 102+17.82) | MILE | 0.116 |
0130 | 732-03-02012 | Plastic Pavement Striping (Dotted Line)(4" W)(3' L)(Thermo 90 mil) | MILE | 0.337 |
0131 | 732-03-02040 | Plastic Pavement Striping (Dotted Line)(8" W)(3' L)(Thermo 90 mil) | MILE | 1.461 |
0132 | 732-04-01120 | Plastic Pavement Legends and Symbols (Arrow - Merge) | EACH | 2 |
0133 | 732-04-05040 | Plastic Pavement Legends and Symbols (EXIT ONLY) | EACH | 2 |
0134 | 732-05-00100 | Removal of Existing Markings | MILE | 20.381 |
0135 | 739-01-00100 | Hydro-Seeding | ACRE | 91.52 |
0136 | 740-01-00100 | Construction Layout | LUMP | 1 |
0138 | 802-03-00100 | Temporary Sheeting (Steel) | SQFT | 42,456 |
0139 | 804-01-00600 | Precast Concrete Piles (24") | LNFT | 47,141 |
0140 | 804-01-00700 | Precast Concrete Piles (30") | LNFT | 14,624 |
0141 | 804-10-00600 | Precast Concrete Indicator Piles (24") | EACH | 5 |
0142 | 804-10-00700 | Precast Concrete Indicator Piles (30") | EACH | 1 |
0143 | 804-14-00100 | Dynamic Monitoring Assistance | EACH | 52 |
0144 | 804-15-00100 | Dynamic Monitoring Instrumentation | LUMP | 1 |
0145 | 804-17-00100 | Construction Site Survey | LUMP | 1 |
0146 | 804-18-00100 | Vibration Monitoring | DAY | 10 |
0147 | 805-01-00100 | Class A1 Concrete (Slab Span) | CUYD | 4,169.53 |
0148 | 805-01-00200 | Class A1 Concrete (Deck) | CUYD | 3,748.24 |
0149 | 805-01-00300 | Class A1 Concrete (Bent Cap) | CUYD | 2,726.59 |
0150 | 805-01-00900 | Class A1 Concrete RETAINING WALL (STA. 547+67.08 - STA. 548+57.08) | CUYD | 15.03 |
0151 | 805-08-01200 | Precast-Prestressed Concrete Girder (Type LG-36) | LNFT | 12,376 |
0152 | 805-16-00100 | Reinforced Concrete Box Culverts (Extension) (4' x 4') | LNFT | 225 |
0153 | 805-16-00600 | Reinforced Concrete Box Culverts (Extension) (5' x 5') | LNFT | 150 |
0154 | 805-16-00800 | Reinforced Concrete Box Culverts (Extension) (7' x 5') | LNFT | 12 |
0155 | 805-18-00100 | Concrete Finish (Class 2 Rubbed Finish) | SQFT | 300,706 |
0156 | 805-18-00200 | Concrete Finish (Class 3 Special Finish) | SQFT | 310,813 |
0157 | 806-01-00100 | Deformed Reinforcing Steel | LB | 2,339,336 |
0158 | 806-03-00100 | Deformed Reinforcing Steel Mechanical Splice (BUTT SPLICE) | EACH | 1,226 |
0159 | 807-02-00100 | Structural Metalwork (Anchor Bolts) | LUMP | 1 |
0160 | 810-01-00120 | Concrete Bridge Railing (36 inch Height) | LNFT | 6,571 |
0161 | 810-05-00330 | Concrete Roadway Barrier (Double Face) (42 inch Height) | LNFT | 23,632 |
0162 | 810-05-00400 | Concrete Roadway Barrier (DOUBLE FACE) (TRANSITION) | LNFT | 3,753 |
0163 | 810-05-00400 | Concrete Roadway Barrier (WITH FOOTING) | LNFT | 3,708 |
0164 | 810-06-00100 | Concrete Pier Protection System (Vehicle) Median Pier Protection | LNFT | 838 |
0165 | 810-06-00100 | Concrete Pier Protection System (Vehicle) Outside Pier Protection | LNFT | 532 |
0166 | 813-01-00100 | Concrete Approach Slabs (Cast-in-Place) | SQFT | 54,048 |
0167 | 814-01-00100 | Elastomeric Bearing Pads (Non-Reinforced) | SFIN | 3,570 |
0168 | 814-02-00100 | Elastomeric Bearing Pads (Reinforced) | SFIN | 2,600 |
0169 | 815-02-00100 | Sealed Expansion Joint (End Dams and Preformed Neoprene Seal) | LNFT | 560 |
0170 | 815-03-00300 | Joint Seal (Poured) | LNFT | 5,265 |
0171 | 816-02-00100 | Bridge End Drain System (Open Drain) | EACH | 18 |
0172 | 822-01-00100 | Trenching and Backfilling | LNFT | 14,600 |
0173 | 822-02-00100 | Conduit w Conductors (PVC/HDPE) (3/4") (1#2 BARE STRANDED GROUND) | LNFT | 400 |
0174 | 822-02-00500 | Conduit w Conductors (PVC/HDPE) (2") (2#2, 1#2 BARE STRANDED GROUND) | LNFT | 50 |
0175 | 822-02-00500 | Conduit w Conductors (PVC/HDPE) (2") (2#8, 1#8 BARE STRANDED GROUND) | LNFT | 1,150 |
0176 | 822-02-00500 | Conduit w Conductors (PVC/HDPE) (2") (EMPTY HDPE DUCT WITH PULL LINE) | LNFT | 13,400 |
0177 | 822-02-01000 | Conduit w Conductors (PVC/HDPE) (6") (VERTICAL CONDUIT CASING) | LNFT | 500 |
0178 | 822-04-00200 | Jacked or Bored Casing (6" Dia) (PVC/HDPE) | LNFT | 1,100 |
0179 | 822-05-00700 | Light Pole (40') (Alum) (Single Arm) | EACH | 6 |
0180 | 822-07-01900 | Luminaire (400 Watt) (High Pressure Sodium) | EACH | 6 |
0181 | 822-07-02500 | Luminaire (1000 Watt) (High Pressure Sodium) | EACH | 32 |
0182 | 822-08-00200 | Electrical Service Point (Structure) | EACH | 1 |
0183 | 822-09-00100 | Electrical System (MEDIAN POLE FOUNDATIONS & ANCHOR BOLTS) | LUMP | 1 |
0184 | 822-09-00100 | Electrical System (Temporary Weigh-In-Motion Station) | LUMP | 1 |
0185 | 822-09-00100 | Electrical System Weigh-In-Motion (Components, Conduit and Conductors) | LUMP | 1 |
0186 | 822-11-00100 | Removal and Disposal of Electrical Equipment | LUMP | 1 |
0187 | 822-11-00100 | Removal and Disposal of Electrical Equipment (Weigh-In-Motion Signs) | LUMP | 1 |
0188 | 822-11-00100 | Removal and Disposal of Electrical Equipment (Weigh-In-Motion) | LUMP | 1 |
0189 | 822-12-00100 | Removal and Storage of Light Pole (Ground Mount) (40' STEEL) (SINGLE ARM) | EACH | 75 |
0190 | 822-12-00100 | Removal and Storage of Light Pole (Ground Mount) (49' STEEL) | EACH | 6 |
0191 | 822-13-00100 | Removal and Disposal of Light Pole Foundation (HIGH MAST) | EACH | 1 |
0192 | 822-13-00100 | Removal and Disposal of Light Pole Foundation (LOW MAST) | EACH | 56 |
0193 | 822-14-00100 | Removal and Disposal of Luminaire | EACH | 113 |
0194 | 822-15-00700 | Relocate Light Poles (40') (Aluminum) (Single Arm) | EACH | 2 |
0195 | 822-15-02100 | Relocate Light Poles (HIGH MAST) | EACH | 1 |
0196 | 822-16-00100 | Underground Junction Box (12" x 12") | EACH | 8 |
0197 | 822-16-00200 | Underground Junction Box (11" x 18") | EACH | 63 |
0198 | 822-16-00300 | Underground Junction Box (13" x 24") | EACH | 8 |
0199 | 822-19-00100 | Modular Breakaway Cable System | EACH | 6 |
0200 | 822-21-00100 | Duct Marker (Concrete) | EACH | 7 |
0201 | 822-22-00300 | Underground Marker Tape (6")(Detectable) | LNFT | 1,200 |
0202 | NS-500-00240 | Sawing and Sealing Transverse Joints in Asphalt Concrete Overlay | LNFT | 3,936 |
0203 | NS-500-00260 | Sawcuts in Asphalt Concrete Lifts | LNFT | 6,560 |
0204 | NS-500-00340 | Saw Cutting Asphalt Concrete Pavement | INLF | 1,090,613 |
0205 | NS-500-00360 | Saw Cutting Asphalt Concrete Pavement Over Portland Cement Concrete Composite Pavement | INLF | 464,288 |
0206 | NS-600-00220 | Saw Cutting Portland Cement Concrete Pavement | INLF | 66,733 |
0207 | NS-602-00011 | Expansion Joint Rehabilitation | LNFT | 57 |
0208 | NS-700-00810 | Impact Attenuator (Construction Zone)(Test Level 3) | EACH | 9 |
0209 | NS-700-00820 | Impact Attenuator Relocation (Construction Zone) | EACH | 49 |
0210 | NS-704-00001 | High Tension Cable Barrier | LNFT | 12,764 |
0211 | NS-704-00002 | Cable Barrier Gated End Terminal | EACH | 10 |
0212 | NS-704-00003 | Concrete Strip | SQYD | 17,019 |
0213 | NS-729-00031 | Breakaway Square Tubing Sign Support (Surface Mount) | EACH | 30 |
0214 | NS-822-00001 | High Mast Luminaire Lowering Device Replacement | EACH | 4 |
0215 | 721-01-00100 | Mowing | CYCL | 24 |
0216 | 805-16-02700 | Reinforced Concrete Box Culverts (Extension) (3' x 3') | LNFT | 18 |
0217 | 712-01-00100 | Concrete Cast-in-Place Revetment (4" Thick) | SQYD | 1,182 |